4.2.20
Advanced Low-Pass Filter Settings (0x0C, 0x50)
Description
Advanced configuration for low-pass filter settings.
The scaled data quantities are by default filtered through a single-pole IIR low-pass filter
which is configured with a -3dB cutoff frequency of half the reporting frequency (set by
decimation factor in the
command) to prevent aliasing on a per data
quantity basis. This advanced configuration command allows for the cutoff frequency to
be configured independently of the data reporting frequency as well as allowing for a com-
plete bypass of the digital low-pass filter.
Possible function selector values:
0x01 - Apply new settings
0x02 – Read back current settings
0x03 – Save current settings as startup settings
0x04 – Load saved startup settings
0x05 – Reset to factory default settings
Possible data descriptors:
0x04 – Scaled accel data
0x05 – Scaled gyro data
0x06 – Scaled mag data (if applicable)
0x17 – Scaled pressure data
Possible filter enable values:
0x01 – Apply low-pass filter
0x00 – Do not apply low-pass filter
Manual filter bandwidth configuration:
0x01 – Use user specified -3 dB cutoff frequency
0x00 – Automatically configure -3 dB cutoff frequency to half reporting rate
-3 dB Cutoff Frequency:
Cutoff Frequency value specified must be no greater than 250 Hz.
**This value in a write command is ignored if Automatic Bandwidth is
selected.
Reserved Byte:
This byte is reserved for internal use and should be left in the 0x00 state