G-Link
®
-LXRS
®
Wireless Accelerometer Node
User Manual
System Operational Overview
22
Synchronized sampling features two data views: Grid view and Graph view. Once sampling is
started, the data grid view is the default view (
Figure 12 - Synchronized Sampling Data View
).
NOTE
When synchronized sampling is set to slower sample rates it may take several
seconds after sampling is initiated for the first sample to appear.
Figure 12 - Synchronized Sampling Data View
a.
Device status:
Node sampling mode and gateway status are displayed in
parentheses next to the device name.
b.
Node information:
includes node serial number and sampling statistics. Right-
click on the node name for more menu options such as Stop Nodes.
c.
Data:
is a display of the sampled data with each channel in a column.
d.
Radio strength:
indicates how good the communication is between the gateway
and node.
e.
Data file:
the location and size of the data file, as data is added. View the data in
.CSV format with the Open File button.
f.
View menu:
Select between Data Grid and Graph views.
g.
End sampling:
The red "X" is used to exit the sampling window and/or end
sampling.