Start-up
- 14 -
11.18
909.1550.1-08
12.4 Call up the secondary parameters
Â
Press button 55 to call up the secondary parameters.
Â
Set the desired secondary parameter by rotating the
control knob 56.
9
The parameter code and the corresponding setting are
displayed alternately in the 7-Segment display 41.
Â
Confirm the secondary parameter by pressing the
control knob 56.
Â
The setting can be adjusted by rotating the control
knob 56.
Â
Confirm the setting by pressing the control knob 56.
Â
The previous or next secondary parameter is dis-
played by rotating the control knob 56.
Different secondary parameters are available de-
pending on the selected operating mode and func-
tion.
Parameter
Code
Default value
Setting range
Mode
Basic Plus Control Pro
Electrode
TIG MIG
Start current
50 % 5...200 %
X
X X
Start current time
0.1 s 0.0 to
20 s
X
X X
Hotstart
125
%
5...200 %
X
X X
Hotstart time
1.0 s 0.0 to
20 s
X
X X
Arc dynamics
100
%
0...200 %
X
X X
The welding current increases automatically as the weld-
ing voltage is reduced. The arc dynamic indicates the ratio
between the welding current and the automatic increase.
Up / Pulses
On
On...OFF
X X
X
The Up and Pulses function can be deactivated or activat-
ed. When switched to "OFF", the Up and Pulses functions
can no longer be selected using button 30.
Up frequency
(correction value)
100
%
0...200 %
X
X
Up welding cur-
rent (correction
value)
100
%
0...200 %
X
X
Up second cur-
rent (correction
value)
100
%
0...200 %
X
X
Up duty cycle
(correction value)
100
%
0...200 %
X
X
Second current I
2
(% of welding
current I
1
)
50 % 1...200 %
X X
X
Parameter
Code
Default value
Setting range
Mode
Basic Plus Control Pro
Electrode
TIG MIG
Pulse frequency
3.0
Hz
0.2 to
2000 Hz
(Repre-
sentation
0.2 to
2.0t)
X X
X
Pulse duty cycle
(% of welding
current I
1
)
50 % 1...99 %
X X
X
Indicates the chronological ratio between welding current
I1 and second current I2 in percent. If the value set is 30,
the ratio is 30% l1 to 70% l2.
Weld end detec-
tion
(correction value)
100
%
0...200 %
X X X X X
Your welding machine switches the welding current off at
a certain arc length. (Weld end detection.) The maximum
length of the arc can be adapted using the "SEE“ parameter.
Inductor effect
(correction value)
100
%
0...200 %
X X X
Hold
OFF OFF, 5,
10, On
X X X X X
After the welding, with Hold = 5, 10 or On, the average values
of the last welding task are visible in the display for 5 sec., 10
sec. or permanently, the LED for V (voltage) or A (amperage)
is flashing. At Hold = OFF the set-value of the welding current
or the actual welding voltage is shown in the display.
Function lock
OFF
On...OFF
(active...
inactive)
X X X X X
Remote control
ON
OFF...On
X X X X X
MMA only
OFF OFF...On
X X X X
Software version
Control panel
-
-
X X X
X
Software version
Master
-
-
X X X
X
Software version
Process
-
-
X X X
X
Tab. 4: Secondary parameters
The factory setting are optimised thanks to auto-
matic parameters.
You can use these factory settings unchanged for
the majority of welding jobs.