page 65
Error codes
As soon as the machine is detecting a malfunction, the power unit is stopped immediately (welding process is in-
terrupted) and the corresponding error code is displayed at the front panel. Every recognized error code together
with the actual operation hour counter is written into the list of last error messages (error memory). A maximum of
16 error codes can be saved.
Using a computer with CAN interface and LorchNet Connect adapter, the error memory can be read out via the
program “Lorch System Manager”.
Code designation
cause
remarks
E01-01 Overtemperature diodes
The maximum temperature was ex
-
ceeded.
fans keep running to cool down the ma-
chine
E01-02 Overtemperature primary modules
E01-04 Overtemperature middle heatsink temp.
E02-02 Overvoltage startup
The DRV measured a too high bus volt-
age during startup.
-check mains and bus voltage
-check wiring between DRV and MAPRO
-
check flat ribbon cable between DRV and
MAPRO
E02-04 Overvoltage primary
The DRV measured a too high bus volt-
age during operation.
E02-05 Overvoltage FPGA
The FPGA on the MAPRO measured a
too high bus voltage.
E04-01 PE-monitoring
A current >15A was flowing via the PE
wire of the mains cable.
-check machine for short circuits to the
housing
-check wiring of the reed contact at con-
nector X15 of the DRV
E05-00 Cooling unit
A flow of the cooling liquid could not be
detected.
-check coolant and cooling unit
-check fuses on pc-board SF 18/23/24/27
-check step-down transformer 400V/230V
-check wiring of pump and sensor
for details see page 49 and page 45
E06-00 Overvoltage secondary
The DSP of the MAPRO measured a too
high output voltage (>100V).
-check wiring of the power unit to pc-board
DC0x (X2)
-check wiring between MAPRO (X5) and
DC0x (X2)
-
check flat ribbon cable between DRV and
MAPRO
E06-01 Overvoltage secondary FPGA
The FPGA of the MAPRO measured a
too high output voltage (>100V).
E07-01 EEPROM initialisation error
Error during reading of the error memory,
accessing the EEPROM memory is not
possible (hardware failure).
Switch machine off and on again. At a
permanent fault, the MAPRO needs to
be exchanged.
E08-00
Wire feed
The wire feed motor draws too much
current.
-check motor and its wiring
-check wiring of the DMR
E08-01 Motor overvoltage
The voltage at the motor is too high
(>100V).
-check motor and its wiring
-check DMRPP05 and its wiring
E08-02 Motor supply
The supply voltage of the motor (60V DC)
is too high (>75V).
E08-03 Motor overcurrent 1
The wire feed motor draws too much cur-
rent (>12A).
E08-04 Motor overcurrent 2
The Push-Pull motor draws too much
current.
E08-05 Tachometer motor 1
The tacho encoder of the wire feed motor
is not connected or faulty.
E08-06 Tachometer motor 2
The tacho encoder of the Push-Pull mo-
tor or NanoFeeder is not working.
E08-10 Torch connection
At the torch trigger wires a voltage > 2.5V
was measured.
check torch trigger wires for short circuits to
other wires
E12-00 Power unit startup
When testing the power unit during ini
-
tialisation (switching on the machine) no
output voltage could be measured.
-check wiring of the power unit to pc-board
DC0x (X2)
-check wiring between MAPRO (X5) and
DC0x (X2)
-
check flat ribbon cable between DRV and
MAPRO