Messages
- 55 -
04.19
909.1709.9-05
Technical data*
Units
Machine type
T 250 DC
ControlPro
T 300 DC
ControlPro
T 250 AC/DC
ControlPro
T 300 AC/DC
ControlPro
Current input I1 no-load
A
0,15
0,15
0,15
0,15
Mains fuse slow-response TIG/EL
A
16
16
16
16
Phase angel cos φ I2 max
cos φ
0,97
0,97
0,97
0,97
Powerfactor λ at I2 max
λ
Max. permissible system impedance Zmax in
acc. with IEC 61000-3-11/-12
mΩ
81
67
76
94
Recommended generator performance
kVA
> 13 / 3 ~
> 16 / 3 ~
> 13 / 3 ~
> 16 / 3 ~
Machine
Protection class
IP
23S
23S
23S
23S
Insulation class
B
B
B
B
Cooling method
F
F
F
F
Noise emission
db(A)
< 70
< 70
< 70
< 70
Norm
EN 60974-1
EN 60974-1
EN 60974-1
EN 60974-1
Designation
CE, S
CE, S
CE, S
CE, S
Dimensions and weights
Dimensions power source (LxWxH)
mm
430 x 185 x 326
483 x 185 x 326
Weight of power source
kg
14,3
14,5
16,3
16,3
Tab. 9: Technical data
ED = Switch-on duration
*) measured at 40° C environmental temperature
18
Messages
18.1 Informative messages
After the message has been output, the
machine will only function to a limited ex-
tent; the error must be corrected as quickly
as possible.
Code
Note
Cause
Possible remedy
H01
Undervoltage
Mains voltage too low
Check mains voltage
H03
Fans
Fan fault
Inform Service
H04
PFC
PFC faulty
Inform Service
H05
EEProm checksum error
Communication with EEProm faulty
Switch machine off and on again, execute
master reset
H06
EEProm write/read error
Communication with EEProm faulty
Switch machine off and on again, execute
master reset
H10
Torch protection
Torch doesn’t send ID although torch
protection is activated
Adjust torch-ID
Tab. 10: Informative messages