Messages
- 28 -
02.16
909.2759.9-00
15 Technical data
Technical data
Units
MicorStick
160
Welding
TIG welding area (I
2min
-
I
2
max
/U
2min
-U
2max
)
A/V
15...160/
10,6...16,4
Electrode welding area
(I
2min
-I
2
max
/U
2min
-U
2max
)
A/V
10...150/
20,4...26,0
Idle voltage U
0
=
U
S
V/DC
70...98
Idle voltage U
r
(VRD)
V/DC
13 - 15
Power setting
infinitely
variable
Slope characteristic
falling
Welding current at ED 100% A
110
Welding current at ED 60% A
120
ED at max. current
%
30
Mains
Mains voltage (50/60 Hz)
V
230/1~
Positive mains tolerance %
15
Negative mains toler
-
ance
%
40
Input power S
1
(100%/40°C)
kVA
3,3
Input power S
1
(60%/40°C)
kVA
3,6
Input power S
1
(max.
current)
kVA
5,2
Current input I
1
(100%/40°C)
A
14,2
Technical data
Units
MicorStick
160
Current input I
1
(60%/40°C)
A
15,6
Current input I
1
(max.Strom) A
22,5
Power factor cos φ (for
I
2 max.
)
0,99
Power factor λ for I
2
max
0,97
Max. permissible sys
-
tem impedance Zmax
in acc. with IEC 61000-
3-11/12
mΩ
321
Mains fuse
A/tr
16
Mains connection
mm²
3x 2,5
Mains plug
Schuko
Machine
Protection class (EN 60529) IP
23S
Insulation class
F
Cooling method
F
Noise emission
dB(A)
< 70
Designation
CE, S
Dimensions and weights
Dimensions (LxWxH)
mm
360 x 130
x 215
Weight MicorStick 160
kg
4,9
Weight MicorStick 160
Accu-ready
kg
4,2
*) measured at 40° C environmental temperature
ED
= Switch-on duration
16 Messages
16.1 Error messages (BasicPlus)
Fault
Possible cause
Rectification
Fault LED 10
flashes
Machine error
Switch the machine off. When all the displays have gone
out, leave the system switched off for at least 1 minute.
Switch the system on again. If the fault persists, contact
the Service department.
Fault LED 10 lit
continuously
ED exceeded, ma
-
chine has overheated
Let the machine cool down whilst switched on