Troubleshooting Steps

Problem:

Possible Cause:

Remedy:

Pilot Will Not Flame

A gas shut off valve is turned off ......................

The gas control knob isn’t turned to “PILOT” .......

The valve control knob isn’t pushed in ...............

The igniter wasn’t pressed repeatedly ...............

No spark from igniter......................................

Check all gas shut off valves

See “Starting the Pilot Flame” Pg 19

See “Starting the Pilot Flame” Pg 19

See “Starting the Pilot Flame” Pg 19

Igniter Faulty - Contact your Dealer

Main Burners Will Not
Start

The pilot flame has gone out ............................

The gas control valve is turned to “PILOT” or “OFF”

The ON/OFF switch is turned to “OFF” ...............

The remote control is not working correctly.........

The thermostat is disconnected or set too high ...

See “Starting the Pilot Flame” Pg 19

See “Starting the Pilot Flame” Pg 19

Turn the ON/OFF switch to “ON”

Replace the batteries

Set the thermostat to a lower
temperature

Remote Control Does
Not Work

The pilot light has gone out..............................

The gas control valve is turned to “PILOT” or “OFF”

The ON/OFF switch is turned to “OFF” ...............

The remote is too far away from the heater .........

The remote control receiver is turned “OFF” ........

One of the two remote control batteries is dead ...

See “Starting the Pilot Flame” Pg 19

See “Starting the Pilot Flame” Pg 19

Turn the ON/OFF switch to “ON”

Use the remote closer to the heater

See the remote control instructions

See the remote control instructions

Thermostat Does Not
Work

The pilot flame has gone out ............................

The gas control valve is turned to “PILOT” or “OFF”

The ON/OFF switch is turned to “OFF” ...............

The thermostat is set too high..........................

See “Starting the Pilot Flame” Pg 19

See “Starting the Pilot Flame” Pg 19

Turn the ON/OFF switch to “ON”

Set the thermostat to a lower
temperature

Optional Blower Does
Not Operate

Make sure blower control is turned “ON”

The heater is not getting electricity ...................

The heater is not up to temperature...................

See “Adjusting Blower Speed”  Pg. 21

Make sure it is plugged in and the
outlet is providing electricity

See “Operating Your Heater”

Flames Are Too Blue

The heater has just been started ......................

This is normal - see “Starting the
Heater for the First Time”

Flames Are Too Short
(Under 6”)

The flame height may be turned too low..............

Turn the flame height to “HI” -
See “Adjusting the Flame Height”

Содержание Spirit DV EF

Страница 1: ...ll gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified...

Страница 2: ......

Страница 3: ...ke the installation and operation of your new heater an easier and more enjoyable experience We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your...

Страница 4: ...ed for NG natural gas This heater is either approved for natural gas NG or for propane LP Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard Di...

Страница 5: ...ce The pilot flame must contact the thermopile and thermocouple see the illustration to the left If it does not turn the gas control valve to OFF and call your dealer A A This unit is not for use with...

Страница 6: ...Two 90 Elbows 12 Termination Requirements 13 Finalizing the Installation 14 Glass Removal Installation 14 Log Set and Coal Installation 15 Door Installation Door Opening Closing 16 Pilot Flame Adjust...

Страница 7: ...n the home s floor plan degree of insulation and the outside temperature Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent of installed syst...

Страница 8: ...efore hooking up this appliance The requirements below are divided into sections all requirements must be met simultaneously Packing List Log Set Coals Propane Conversion Kit Owner s Pack door handle...

Страница 9: ...3 45 kPA For pressures under 1 2 psig 3 45 kPA isolate the gas supply piping by closing the manual shutoff valve This heater is designed for natural gas but can be converted to propane Check the stick...

Страница 10: ...g and storm collar whenever passing through the roof Duravent Part 953 943 or 943S 8 5 8 Use a support box on exposed vent Vertical Vent Requirements Use a wall thimble whenever passing through a wall...

Страница 11: ...AAAAAAA AAAAAAAA To Adjust the Restrictor 1 2 3 4 The eleven holes on the restrictor plate correspond to the eleven restrictor positions NOTE Position 1 is the fully open position Determine the correc...

Страница 12: ...Offset Vertical Rise AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA 5 feet 10 feet min 15 feet 20 feet 25 feet 30...

Страница 13: ...icated restrictor position AAAAAAAAA AAAAAAAAA AAAAAAAAA AAAAAA AAAAAA AAAAAA AAAAAA 5 feet min 10 feet 0 feet 11 max 5 feet 10 feet 0 feet 5 feet 10 feet 12 max 5 feet min 0 feet 0 feet NOTE Horizont...

Страница 14: ...AAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAAAAAAAA AAAAAAAA...

Страница 15: ...when adjacent to public walkways or driveways NOTE may not be used over a walkway or driveway shared by an adjacent building I Minimum 48 clearance from any mechanical air supply inlet 72 for Canada...

Страница 16: ...Nuts a 5 16 Nutdriver AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA AAAAAA b Loosen the nuts on the bottom and left side glass clip Then slide the glass to the right pivot the glass forward and remove it...

Страница 17: ...ts on the burner insert into the holes on the bottom of the log Place the right log so the pins or bolts on the burner insert into the holes on the bottom of the log Place the rear log so the pins on...

Страница 18: ...pins from the heater Attach the hinge plate to the door frame with the two remaining screws Make sure the plate butts up against the outside edge of the door frame a Place the door face down on a non...

Страница 19: ...ltitude and vent configuration Gas Control Valve NOTE If the air shutter is all the way open yet the flames remain sooty shut off gas to the fireplace and contact a qualified gas service technician Co...

Страница 20: ...ol is used to turn the main burner on and off Gas Control Knob This knob is used to control gas to the heater and for starting the pilot There are three positions ON OFF PILOT The pointer to the left...

Страница 21: ...he directions on the cover IF YOU SMELL GAS c Turn the gas control knob to the PILOT position and press the knob in this will allow gas to flow to the pilot light Press the button on the pilot igniter...

Страница 22: ...F SE T TE MP TIM ER MI N Tim e Se t Tim e Ca nc el A u t o OF F ON Use this switch to turn the main burner on and off manually After the pilot has been started See the instructions included with the...

Страница 23: ...d This is the valve opening up and shutting down Blower Snap Disk This part can produce a clicking sound as it turns the blower on and off The appliance will creak with change of temperature Pilot Fla...

Страница 24: ...heck the firebox and area around the pilot to make sure there is no warping or damage If any problem is found discontinue use and contact your dealer for service AA AA AA A A Check the burner holes Ma...

Страница 25: ...switch is turned to OFF The remote is too far away from the heater The remote control receiver is turned OFF One of the two remote control batteries is dead See Starting the Pilot Flame Pg 19 See Star...

Страница 26: ...in burners are switched on and off using the electricity generated by the thermopile The ON OFF switch remote control or thermostat control the circuit to the main burner ON OFF MAIN BURNER What Preve...

Страница 27: ...Electrode Pilot Hood On Off Switch Brown Optional Thermostat 7 4 10 9 1 3 Optional Blower Green Hot black Common white Ground green Blower Snap Disk Power In Molex Connector Power Supply Ground attach...

Страница 28: ...both may need to be changed See the owner s manual for information on making these changes WARNINGS Improper installation adjustment alteration service or maintenance can cause injury or property dam...

Страница 29: ...condensation c Any damage to the unit combustion chamber heat exchanger or other components due to water or weather damage which is the result of but not limited to improper chimney venting installat...

Страница 30: ...shelves are in the forward corners when the burner is replaced AA AA AA A A Reach into the firebox and slide the burner to the left then lift it upwards lift the burner from below Do not lift the bur...

Страница 31: ...a 1 2 open end wrench to unscrew the burner orifice NOTE Screw the LP orifice in so the orifice shoulder protrudes 5 16 indicating full insertion 3 2 5 0 The new LP orifice has 50 stamped on it The ol...

Страница 32: ...Close door 7 Remove the regulator from the front of the gas control valve Replace with the propane regulator using the new gasket and screws included with the regulator NOTE Leak test this area after...

Страница 33: ...r Modulating Remote Bracket Installation If you are using a modulating remote install the included bracket onto the back of the stove following the directions below 1 Install the bracket as shown in t...

Страница 34: ...Housing Phillips Screwdriver 7 16 Socket Wrench 2 Install the roller plate following the directions below 11 32 Socket Wrench with Extension Roller Plate Reach in and poke out this cover plate it is h...

Страница 35: ...DENDUM 2 Interior Masonry Chimney Conversions Follow the requirements and use the equipment listed in the illustration to the right to install this appliance into an interior masonry chimney Maximum v...

Страница 36: ...ination Requirements 13 How to Measure Vent Lengths 9 Installation Options 5 Installation Preparation 6 Leaking Gas See Inst on Cover Lifting Flames 17 Listing Label Safety Label 26 Log Installation 1...