62 Installation
(for qualified installers only)
© Travis Industries
11/9/20 - 1478
PB 72 GSB2/GSR2 Aust.
CoolSmart TV - Combustible “Over-Facing” (Optional)
When using the CoolSmart TV kit, Combustible material can be installed over the front of the fireplace.
The combustible material MUST be installed over ½” non-combustible board. See the two options
below.
NOTE:
The maximum facing depth (combu non-combustible facing) is 1-1/4” (32mm). Any
facing that extends farther than 1-1/4” (32mm) must meet mantel clearances.
WARNING
: The front of the appliance is subject to high temperatures which may cause discoloration
and/or material degradation. Take this into account when choosing finishing materials.
Installation With Thick Facing Guide (facing butts thick facing guide) - STANDARD
NOTE:
Leave the thick facing
guide in place on the
fireplace.
NOTE:
The screen assembly
mounts should be left in
the stock position (all the
way in).
Installation Without Thick Facing Guide (screen assembly overlaps facing)
Note:
Remove the thick facing
guide on the fireplace (it
is not used with this
configuration).
Note:
The screen assembly
mounts will need to be
moved out to
accommodate the
thickness of the facing
(see installation manual
for details).
Warning
:
When not using the thick
facing guide, a 3/16” (4.8mm)
air space is required from all
four sides of the tile stop on
the fireplace to the
combustible facing (see
details below).
Non-Combustible
Screen Assembly
Tile Stop
Thick Facing
Th
Guide
Fireplace side
Facing Only
Combustible Facing
Combustible
Max Depth
1-1/4” (32mm)
Facing
Allowed
OVER
Non-Combustible board
Non-Combustible
Screen Assembly
Tile Stop
Fireplace side
Facing Only
Combustible Facing
Combustible Facing
Allowed
OVER
Non-Combustible board
Required
3/16” (4.8mm)
Air Space