34 Installation
(for qualified installers only)
© Travis Industries
11/9/20 - 1478
PB 72 GSB2/GSR2 Aust.
Standard vs. Extended Position
The nailing brackets on the side of the fireplace may be placed in the standard or extended position to
best suit the facing being used (the header shield is also moved). Most installations use the standard
nailing bracket position. If using a facing that does not use a backing board (e.g. marble), you may wish
to use the extended position.
Standard Position - Top View
(nailing brackets as shown to right)
Optional Tile
(or other non-combustible)
Drywall
Cement Board
(or other non-combustible)
Nailing Bracket
Fireplace
Framing
Non-Combustible Facing
(marble, etc.)
Drywall
Nailing Bracket
Fireplace
Framing
Extended Position - Top View
(nailing brackets as shown to right)
Nailing Bracket
Nailing Bracket