background image

 Maintenance 

 (for qualified service personnel only)

 

45 

© Travis Industries 

4160713 

100-01442 

Accent Light Replacement 

An accent light is included in your stove to provide additional lighting.  This bulb will burn out over time.  
To replace, follow the directions below: 

 

Shut off gas to the stove and let it cool for 15 minutes.

 

 

Remove the glass (see page 28) and logs (see page 30).

 

 

Replace the halogen bulb with the following bulb: 

NOTE

: .Take care to not touch the bulb with your fingers – use foam packing or paper towel to hold the bulb.

 

35 Watt 120 Volt T4 Halogen Bulb (GY6.35 Base)

 

 

Yearly Service Procedure 

 

Failure to inspect and maintain the stove may lead to improper combustion and a potentially 
dangerous situation.  We recommend the following procedures be done by a qualified technician.

 

1.  Turn the pilot flame to continuous.  It should touch approximately 3/8" of the 

top of the flame sensor.  If it does not, contact your dealer for service. 

2.  Shut off gas to the stove and let it cool for 15 minutes.  Remove the glass 

(see page 28). 

3.  Remove the log set (

NOTE: The logs are very fragile - 

see page 30).  If 

severely deteriorated, replace.  Check the logs for sooting.  A small amount 
of soot along the bottom of the logs is normal.  If excessive sooting is 
found, the stove will require adjustment.  Contact your dealer. 

4.  Inspect the burner and remove any debris. 

 

Make sure the burner is not warped, cracked, or damaged.   

 

Check the firebox and area around the pilot to make sure there is no warping or damage. 

 

If any problem is found, discontinue use and contact your dealer for service. 

5.  Install the log set.  Clean and replace the glass.  If the glass is damaged, replace.  Make sure the 

gasket along the perimeter of the glass contacts the face of the firebox and forms an air-tight seal.  If 
it does not, re-align or replace the gasket to insure an air-tight seal.   

6.  Inspect the area behind the access door.  Clean if necessary.  Check the gas control valve and the 

gas lines.  If damage is found, discontinue use and contact your dealer for service.  Clean the air 
channels, ducts, and blower (if applicable). 

7.  Start the main burner.  After 15 minutes the flames should be orange/yellow and not touch the top of 

the firebox.  If the pilot or main burners do not burn correctly, contact your dealer for service.  Monitor 
blower operation.   

8.  Remove any debris or vegetation near the vent termination.  Contact your dealer if any sooting or 

deterioration is found near the vent termination. 

Содержание NorthField GSR2 Deluxe

Страница 1: ...OT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at risk individuals Tested and Listed by ANSI Z21 88 2014 CSA 2 33 2014 Built In Direct Vent Stove Natural Gas or Propane Residential or...

Страница 2: ...Information No other Northfield Stove has the same serial number as yours The serial number is on the listing plate chained to the gas control valve This serial number will be needed in case you require service of any type Model Lopi Northfield GSR2 Serial Number Purchase Date Purchased From Mail your Warranty Card Today and Save Your Bill of Sale To receive full warranty coverage you will need to...

Страница 3: ...sonry Chimney Conversions top vent configuration only 25 Steps for Finalizing the Installation 26 Air Shutter Adjustment 27 Face and Glass Removal 28 Log Installation 30 Ember Placement 33 Rockwool Installation 33 Before You Begin 34 Remote Set Up 35 Verify the Switch is on REMOTE 35 Synchronize the Transmitter to the IFC 35 Clearing the System Memory 35 Location of Controls 36 Direct Operation 36...

Страница 4: ...d in Manufactured Housing only after the home is site located All exhaust gases must be vented outside the structure of the living area Combustion air is drawn from outside the living area structure The venting must not be connected to a chimney flue serving a separate solid fuel burning appliance Notify your insurance company before hooking up this fireplace The instructions in this manual must b...

Страница 5: ...s usually next to the gas meter or propane tank and requires a wrench to shut off A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at risk individuals If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance Clothing or othe...

Страница 6: ... square feet 500 to 850 Maximum Input in BTUs 22 000 Heating capacity will vary depending on the home s floor plan degree of insulation and the outside temperature Dimensions Weight Electrical Specifications Electrical Rating 120 Volts 1 5 Amps 60 Hz 180 watt Fuel This heater is shipped in natural gas NG configuration but may be converted to propane LP using the included LP conversion kit The stic...

Страница 7: ...m with In USA Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 In Canada CSA Z240 4 and Gas Equipped Recreational Vehicles and Mobile Housing This appliance may be installed in Manufactured Housing only after the home is site located This stove is designed to operate on natural gas or propane LP All exhaust gases must be vented outside the structure of the living area Comb...

Страница 8: ...over Intake Damper Plates 2 Exhaust Restrictor Extender Plate Additional Items Required Vent see Venting Requirements for details Gas Line Equipment shutoff valve pipe etc LP Units Require GSR Stepper Motor 4 pack 94400999 single 250 01463 Installation Overview See Vent Requirements See Floor Protection Requirements See Gas Line Installation See Clearances ...

Страница 9: ...l We recommend you open windows to vent the room Stove Clearances NOTE If using the rear vent configuration you will require approximately 8 1 2 to the rear of the stove for the vent adapter and thimble See page 17 for details Mobile Home Requirements When the stove is installed in a mobile home it must be bolted to the floor and the appliance grounded use the optional blower with a grounded circu...

Страница 10: ...netic tipped nutdriver on these screws take care to prevent the screws from falling into the intake channel Remove the diffuser Before Stock Position 1 After Position 2 DIFFUSER SIDE VIEW Bend the round portion of the diffuser so it is bent position 2 Replace the diffuser ADJUSTING THE DIFFUSER ON THE INNER FLUE ASSEMBLY Rear vent configurations with no rise require the diffuser to be bent to the ...

Страница 11: ...r plate Make sure the attached gaskets are in place and form an air tight seal NOTE Install the flue assembly with the diffuser to the bottom Install the outer flue assembly cover plate and gaskets Make sure the gaskets are correctly positioned and form an air tight seal The flue cover with a cutout may be discarded Use the flue cover designed for rear vent applications ...

Страница 12: ...d so the vents below or above the door along the sides of heater or along the back of the heater can become blocked This heater may be placed in a bedroom Please be aware of the large amount of heat this appliance produces when determining a location Floor Protection Requirements When the stove is installed directly on carpeting vinyl or other combustible material other than wood flooring or a hig...

Страница 13: ...s required for installation it must be located within 3 of the heater T Handle gas cocks are required in Massachusetts in compliance with code 248CMR This stove is shipped with a 16 long 3 8 diameter flex gas line attached to an elbow on the gas control valve see illustration below for location The flex accepts a 3 8 flare fitting Gas Inlet Pressure Gas Pressure Max Input Pressure Min Input Pressu...

Страница 14: ...roved for this stove Approved Vent Use Simpson Dura Vent Direct Vent Pro or GS Other vent may be approved with this stove Check with the vent manufacturer for details Vent Diameter is determined by vent configuration Rear vent configurations with no rise use 8 203mm diameter vent all other vent configurations use 6 5 8 168mm See Approved Vent Configurations on page 15 for details Installation inst...

Страница 15: ...alled Two intake damper plates are included in the owner s pack They are installed behind the burner in certain vent configurations See page 50 for details on removing the burner To Adjust the Restrictor 1 2 3 4 5 NOTE Position 1 is the fully open position Determine a restrictor position see the charts under Approved Vent Configurations Remove the screw Rotate the adjustment plate counter clockwis...

Страница 16: ...rictor to the correct restrictor position see the illustration below The screw location indicates restrictor position In this example the restrictor is set in position 3 Tighten the screws to secure the restrictor closed 5 4 3 2 open stock position 1 Back Wall of Firebox Firebox Roof Exhaust Restrictor Extender Plate found in the owner s pack Remove these two screws on the exhaust restrictor Back ...

Страница 17: ...lbow may be used between horizontal sections Diffuser must be set to closed 2 position Intake restrictor set to 1 stock Exhaust restrictor must be set to the 1 stock position except for LP extended vent configurations remove the exhaust restrictor and replace the screws Do not install the intake damper plate or exhaust restrictor extender plates Corner Installations 6 5 8 to 8 Adapter High Wind Ho...

Страница 18: ...htly especially when the termination is near a demarcation line Diffuser set to open stock position Do not install the intake damper plate or exhaust restrictor extender plates 5 feet 1 5m 10 feet 3m 0 feet 5 feet 1 5m 0 feet 0 feet 10 feet 3m 0 feet 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 24 max 7 3m Min 1 03m Vertical Section Required 12 feet max 3 6m Exhaust Restrictor Position 5 Intake ...

Страница 19: ... NOTE Restrictor positions are based upon lab tests The ideal restrictor position may vary slightly especially when the termination is near a demarcation line Diffuser set to open stock position Install the intake damper plate Install the exhaust restrictor extender plate 0 feet Exhaust Restrictor Position 5 Intake Restrictor Position 6 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 25 feet 7 5m 3...

Страница 20: ... to combustibles must be met and the flex vent must be vented through a non combustible stove chimney Use a high wind termination cap Vent height must be a minimum 10 and maximum 25 Diffuser must be set to closed 2 position Intake and exhaust restrictor must be set to the 1 stock position Do not install the intake damper plate or exhaust restrictor extender plates Liner Termination Kit Flashing an...

Страница 21: ...ion line Diffuser set to open stock position Install the intake damper plate Install the exhaust restrictor extender plate 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 25 feet 7 5m 30 feet 9m 40 max 12m 5 feet 1 5m 0 feet 0 feet 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 25 feet 7 5m 30 feet 9m 40 max 12m 10 feet 3m 15 feet 4 5m 20 feet 6m 24 max 7 3m 0 feet 5 feet 1 5m 10 feet 3m 15 feet 4 ...

Страница 22: ...ination is near a demarcation line Diffuser set to open stock position Do not install the intake damper plate or exhaust restrictor extender plates 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 5 feet 1 5m 0 feet 0 feet 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 10 feet 3m 15 feet 4 5m 20 feet 6m 24 max 7 3m 0 feet 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 24 max 7 3m 0 feet Exhaust Rest...

Страница 23: ...he requirements of the gas supplier G Minimum 48 1219mm clearance from any adjacent building H Minimum 84 2134mm clearance above any grade when adjacent to public walkways or driveways NOTE may not be used over a walkway or driveway shared by an adjacent building I Minimum 9 229mm clearance to any nonmechanical air supply inlet to the building or the combustion air inlet to any other appliance J M...

Страница 24: ...it A 931 Metalbestos 6 I D Security Chimneys 6 I D Jackes Evans 6 I D Hart Cooley 6 I D Pro Jet 6 I D Chimney Conversion Kit B 932 Simpson Dura Vent 6 I D Air Jet 6 I D Metal Fab 6 and 7 I D Amer Metals 6 7 I D Metalbestos 7 and 8 I D Jackes Evans 7 and 8 I D Hart Cooley 7 and 8 I D Pro Jet 7 and 8 I D Security Chimneys 8 I D Chimney Conversion Kit C 933 Simpson Dura Vent 7 and 8 I D American Meta...

Страница 25: ...pect the chimney 711 Flex Liner 4 dia or other UL 1777 Gas Liner Co Axial Straight Lengths 991 High Wind Termination 990 90 Elbow Flashing included in 934 Masonry Conversion Kit Make sure the coaxial pipe maintains a 1 clearance to any combustible The vent must be sealed air tight High Temp Silicone Connector with Cover included in 934 Masonry Conversion Kit Interior Masonry Chimney Standard Mason...

Страница 26: ...s does not build up 3 Install the four AA batteries into the battery holder see illustration below The AA batteries act as a power backup in case the household AC power goes out and are required for operation Install three AAA batteries into the remote see illustration below Synchronize the transmitter to the IFC 4 Make sure the accent light bulb is in place and works correctly NOTE Take care to n...

Страница 27: ...lames should not contact the top of the firebox Check the flame on low position The flames should burn off of each burner hole If the heater does not work correctly contact your Travis dealer for a remedy 11 Give this manual to the home owner for future reference and fully explain operation of this heater Correct Flames should be blue at the base yellow orange on the top If the flames are too tall...

Страница 28: ...ve top off the stove and place it aside a Re Attaching the Glass Frame a Slide the two brackets on the bottom of the glass frame into the glass frame guides hold the glass frame at a slight angle b Swing the glass frame into place you may have to lift it slightly to allow it to fit over the top of the firebox c Attach the upper latches follow the instructions above in reverse d Replace the stove f...

Страница 29: ...d 1 4 turn when it is disengaged Follow the directions below to re install the latch if it becomes loose Top of Firebox Hold the latch at an angle and insert it into the slot on the glass frame anchor NOTE this slot may be at a different angle than illustrated Note how the washer on the latch fits behind the flange on the glass frame anchor Glass Frame Anchor Once fully inserted turn the latch unt...

Страница 30: ...or failure to use only parts specifically approved with this appliance may result in property damage or personal injury If using propane LP convert the appliance before installing the logs see page 50 The burner must be correctly positioned before installing the logs Make sure the burner is fully seated and the pilot is properly aligned See page 50 for details on burner removal Rear Log Placement ...

Страница 31: ...e hole and one elevated pad on the bottom Place the log so the pin on the burner inserts into the holes on the log and the pad inserts over the screw on the burner see photos below Right Log Placement The right log has two holes on the bottom Place the log so the two pins on the burner insert into the holes on the log see photos below ...

Страница 32: ...o below The bottom of the twig has two holes Place the twig so the pins on the rear and left log insert into the holes on the twig Right Twig Placement The right twig has two holes in the bottom that fit over the pin on the back and right log see photos below The lower side of the twig rests on the right log Place the twig as shown below Left Twig Right Twig ...

Страница 33: ... is placed on top of the burner to enhance the glow from the burner The rock wool works best when it is applied in a very thin porous layer The best method for applying the rock wool is to brush it on to the burner Compress a clump of rockwool between your thumb and forefinger Use a stiff brush to apply a thin layer of rockwool fibers onto the burner Do not use the entire bag of rockwool Use only ...

Страница 34: ...ame height blower light comfort control Standing Pilot or auxiliary power input This allows you to tailor the remote to the appliance We do not recommend disabling the standing pilot option for our gas appliances This feature may be recommended for cold regions or installations with sub optimal venting How to Disable Enable the Thermostat The remote is shipped with the thermostat enabled 1 Remove ...

Страница 35: ...ill beep 3 times Press the ON button on the transmitter IFC will beep 3 times NOTE If power is cut off to the IFC for an extended period of time you may need to re synchronize the remote Clearing the System Memory This appliance uses an Integrated Fireplace Control IFC to store the unique code for the remote control If you wish to clear the system memory MAKE SURE GAS IS TURNED OFF TO THE APPLIANC...

Страница 36: ...TE When the battery holder switch is turned to ON or OFF the mode settings Flame Height Comfort Control will remain in the same state as before the switch was moved i e the IFC remembers the last setting If you wish to adjust the mode settings use the transmitter mode button to adjust the settings see Mode Controls on page 40 The thermostat and burner on off operating functions will not work on th...

Страница 37: ...e burner If this is situation we recommend you switch to continuous pilot This will create a slight draft in the vent allowing for the burner to light quickly and draft correctly Excessive Condensation on Glass After Startup certain installations may encounter excessive fogging on the window after startup not just the first time the heater was started This is an aesthetic condition that may be rem...

Страница 38: ...illustration below Listen for the Beep Each time you press a button on the transmitter that controls the fireplace a beep will come from the IFC When you change thermostat target settings the IFC will not beep NOTE When the batteries start to get low the IFC will beep twice whenever a button is pressed When the batteries are nearly depleted the IFC will no longer beep See IFC Batteries on page 42 ...

Страница 39: ...eved STANDARD THERMOSTAT While in standard thermostat setting the transmitter will turn the burner on and off to achieve the target temperature see illustration below To adjust the target temperature press the up and down buttons until a suitable temperature is achieved NOTE If the transmitter batteries go dead while in thermostat setting standard or smart the appliance will shut off after approxi...

Страница 40: ...r display will display the 7 settings from OFF to HI for full on MANUAL MODE BLOWER OPERATION When in Manual Mode the blower will remain on even if the burner is turned off and the heater cools Either manually turn the blower off or turn off the heater by pressing the On Off button F Flame Height OFF Look here for mode controls Press the mode button to cycle through the mode settings Optional Blow...

Страница 41: ...be turned on and off using the up and down buttons when in Comfort Control Mode see illustration below The center display will display either ON or OFF Display Fahrenheit or Celsius With the system in the OFF position press both the MODE and THERMOSTAT buttons simultaneously to toggle between Fahrenheit F and Celsius C F OFF MAX When in accent light mode this icon will appear darkened This is the ...

Страница 42: ... In applications where the appliance is required to provide heat we recommend replacing the batteries before each heating season Battery Replacement Battery Installation Install four AA batteries into the battery holder see illustration below These batteries act as a power backup in case the household AC current goes out Transmitter Battery Installation Install the three included AAA batteries int...

Страница 43: ...ring start up You may notice the smell is more acute if the appliance was left idle for a long period MAX F OFF Child Proof Indicator Gas Control Valve As the gas control valve is turned on and off you will hear a dull clicking sound This is the valve opening up and shutting down The appliance may creak with change of temperature THIS IS NORMAL Pilot Flame The pilot flame will make a clicking soun...

Страница 44: ... directions below 1 Let the stove cool Clean the area thoroughly 2 Shake the Travis Enamel Touch Up thoroughly Apply to the damaged area Patina Surfaces The patina finish is a living color and will age and antique over time Some portions of the finish may become slightly dull in appearance especially over the top where it becomes hot This is normal The only cleaning we recommend is a light dusting...

Страница 45: ...ce Check the logs for sooting A small amount of soot along the bottom of the logs is normal If excessive sooting is found the stove will require adjustment Contact your dealer 4 Inspect the burner and remove any debris Make sure the burner is not warped cracked or damaged Check the firebox and area around the pilot to make sure there is no warping or damage If any problem is found discontinue use ...

Страница 46: ... the fuse See fuse location below Stove Will Not Distribute Heat The stove is not getting electricity The stove is not up to temperature Check the breaker switch Let the stove burn for at least 15 minutes Flames Are Too Blue The stove has just been started Improper air shutter adjustment This is normal see Starting the Stove for the First Time Adjust Air Shutter contact your dealer Flames Are Too ...

Страница 47: ... Purple Grey Pilot Sensor Spark Rod Comfort Control Valve Battery Box Manual On Off Accent Light s 3 Amp Fuse Optional Blower s 3 Amp Fuse Appliance Ground Accessory Power Appliance Ground Green Orange Yellow Green White Blue IPI CPI JUMPER WIRE Blue Pink Power In TOP 4 AA Batteries Black Red Yellow Orange Yellow Flame Detect Black Red Purple Grey Black White Green Integrated Fireplace Control IFC...

Страница 48: ...ent system to vent this appliance to the exterior See owner s manual for approved brands of venting If the vent air intake system is disconnected for servicing or any other reason it must be resealed and or reinstalled WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance F...

Страница 49: ...he manufacturer s settings of components lack of proper and regular maintenance damage incurred while the appliance is in transit alteration or act of God 8 This 7 Year warranty excludes damage caused by normal wear and tear such as paint discoloration or chipping worn or torn gasketing corroded or cracked logs embers etc Also excluded is damage to the unit caused by abuse improper installation mo...

Страница 50: ...ng jurisdiction If the information in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specified in ...

Страница 51: ...so the orifice protrudes 15 16 24mm indicating full insertion c Look here for the orifice identification Apply thread sealant to the LP orifices prior to installation Use the chart below to identify the correct orifices Front Rear NG 54 52 LP 64 58 b 1 2 Wrench Use a 1 2 open end wrench to unscrew the two orifices Front Burner Orifice a Rear Burner Orifice 15 16 24mm ...

Страница 52: ...move the control panel to access the gas control valve The stepper motor adjustable regulator has an installation sheet included with it make sure to follow all of the directions Place the stepper motor on the gas control valve see pictures below MAKE SURE IT IS CORRECTLY ORIENTED Secure using the screws included with the motor tighten to 25 Lb inches Leak test this area after installation to veri...

Страница 53: ...Optional Equipment for qualified installers only 53 Travis Industries 4160713 100 01442 ...

Страница 54: ...n of Controls 36 Log Installation 30 Low Battery Indicator 42 LP Conversion Instructions 50 Maintaining Your Stove s Appearance 44 Mobile Home Requirements 9 Normal Operating Odors 43 Normal Operating Sounds 43 Packing List 8 Power Outages 42 Rear Vent Configuration Vented into Stove with Co Linear Adapter 20 Rear Vent Configurations with Horizontal Termination and 1 Min Rise 18 Rear Vent Configur...

Отзывы: