background image

HERITAGE  DVL 

Direct Vent Large Gas Stove

TM

Your 
Authorized 
Dealer Is:

©Copyright 2002 T. I.       Printed In U.S.A.         Lopi reserves the right to alter or improve its products at any time without notification.

NOTE: Improper installation of your gas appliance or failure to operate it according to 
the guidelines detailed in the Owner's Manual, may negate your warranty and endanger 
your home and family.  Contact local building or fire officials about restrictions and 
installation requirements in your area.

SAFETY TESTING:

DIRECT VENT tested by OMNI-Test Laboritories, Inc., to ANSI 

Z21.88/CSA 2.33-1998, and applicable sections of UL 307b and CAN/CGA 2.17-M91 and 
other requirements listed in the Owner’s Manual.

Visit our WEB site at: www.lopistoves.com

HEATING CAPACITY: May vary depending on the degree of home insulation, floor plan and the ambient temperature zone of the area in which you live.

Available with black door and black grill 
and can be upgraded with the optional 
24 karat plated gold door and gold 
convection grill. 

Large design - Ideal for home or multiple 
room heating.

Approved for residential, mobile home 
and bedroom applications.

Award winning Ember-Fyre Burner, 
(patent pending) the most realistic fire.

Heater Rated.

Millivolt system allows the stove to operate 
even during power outages.

30 second pilot drop-out switch for safety.

Heat output can be adjusted down 
without the loss  of the beautiful flame 
and glowing embers.

Ships with NG burner installed, and includes 
an easy-to-convert LP conversion kit.  

Delicate cast molding detail on stove top 
& pedestal base.

Standard 130 CFM convection blower.

Optional two-tone brick pattern fireback.

Optional wall switch, wall thermostat 
and remote control thermostat.

Optional modulating remote control 
thermostat that allows you to 
simultaneously adjust the flame height 
and convection blower speed.

Fuel

Steady State

Efficiency (NG)

Natural Gas (NG)

or

Propane (LP)

Heating

Capacity

Up to 

2,000 sq. Ft.

Direct Vent

6 5/8" 

DuraVent

Direct Vent

Standing Pilot

Generates Electricity to 

Allow Operation Even 

During Power Outages

(NG) 29,600 to 43,000 Btu's/Hr.

(LP) 26,000 to 43,000 Btu's/Hr.

Input

Adjustable

AFUE

71% (NG)

73.7% (LP)

83% NG - 86% LP

78% NG - 81% LP

Ember-Fyre 

Burner

The breakthrough Ember-Fyre™ burner 
(patent pending) features a level of 
realism and efficiency so remarkable 
that it is difficult to tell apart from 
our real wood-fired stoves.

#1

 Gas reaches the appliance, 

through a high quality European 
SIT gas valve.

#2

 The SIT valve has a variable 

turn down rate from a high of 
43,000 BTU’s to a low of 23,000 BTU’s. 
The valve steps down and lowers 
pressure gas as it flows into the burner 
orifice.

#3

 The orifice is a small opening 

specifically designed and machined to 
allow a precise gas flow into the burner.

#4

 Unique to the Ember Fyre burner, 

the combustion air is drawn from 
outside the house via the direct 
vent flue. This air is preheated 
and drawn into the lower 
portion of the sealed firebox.

#5

 A portion of this air is drawn directly into the mixing tube.

#6

 The mixing tube combines the gas from the orifice with combustion air and 

directs this mixture to the burner. 

#7

 The fuel/air mixture is fine tuned to your installation with a one time adjustment 

using the air shutter control. This control allows the installer to compensate for 
variations in altitude, fuel type and line pressure. 

#8

 This gas/air mixture flows toward the lower burn chamber. 

#9

 The burn chamber is a hollow area formed between a metal pan and the Ember-

Fyre™ burner (patent pending). 

#10

 From the sealed chamber the gas/air mixture flows through a unique array of 

precise burner ports. There are no visible burner tubes or steel grill components 
that one normally sees in a typical gas appliance.

#11

As this mixture ignites and burns, the Ember-Fyre burner heats to a deep red 1200˚ 

F, realistically mimicking the look of burning wood embers. The hand-carved ceramic 
logs have the appearance of partially burned wood. Dancing yellow flames further 
enhance the look and feel of a real wood fire.

#12

 The optional Modulating Remote Control is also available that allows you to 

remotely adjust both the flame height and the speed of the variable speed blower. The 
optional blower is required to utilize this feature.

12

2

1

3

4

5

6

7

8

9

11

10

Use these 
dimensions when 
determining
clearances to 
combustibles.

Stove 
Dimensions

27 3/8"

33 3/8"

20 3/8"

27 3/8"

13 5/16"

8 1/4"

When the stove is installed directly on carpeting, vinyl or combustible floor other than wood flooring, 
the stove must be installed on a metal or wood protection panel, extending the full width and depth 
of the stove. (Minimum 27 3/8” wide x 20 3/8” Deep).

10"
4"
4"

20 3/4"
7"
11 3/4"

Clearances To Unprotected Combustible Walls

Stove clearances measured from stove top.  Connector clearances measured from flue pipe.

Straight Installation

Corner Installation

Alcove Installation

Floor Protection

J = Minimum Width    47 3/8"
K = Maximum Depth   48"
L = Minimum Height   60"

A = Stove Top to Sidewall
B = Stove Top to Backwall
C = Stove Top to Corner Wall

D = Connector to Sidewall
E = Connector to Backwall
F = Connector to Corner Wall

BACKWALL

SIDEW

ALL

CORNER WALL

CORNER W

ALL

J

K

L

D

A

E B

C

F

Shown with standard Black Door & optional Gold Grill.

Отзывы: