background image

 

Berkshire MV 

Owner’s Manual

 

 

 

 WARNING: FIRE OR EXPLOSION HAZARD 

Failure to follow safety warnings exactly could result in serious injury, death, or property damage. 

 

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any 
other appliance. 

WHAT TO DO IF YOU SMELL GAS

 

• Do not try to light any appliance. 
• Do not touch any electrical switch; do not use any phone in your building. 
• Leave the building immediately 
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's 

instructions. 

• If you cannot reach your gas supplier, call the fire department. 

-  Installation and service must be performed by a qualified installer, service agency or the gas supplier.

 

 

 

HOT GLASS 

WILL CAUSE 

BURNS

 

DO NOT TOUCH 

GLASS 

UNTIL COOLED

 

NEVER 

ALLOW CHILDREN 

TO TOUCH GLASS

 

A barrier designed to reduce the risk of burns from 
the hot viewing glass is provided with this appliance 
and shall be installed for the protection of children 
and other at-risk individuals. 

Tested and Listed by 

 

Report # 0028GF031S

 

Omni-Test Laboratories, Inc. 

Portland, Oregon 

ANSI Z21.88-2016 

CSA 2.33-2016 

CGA 2.17-M91 (R2014) 

 

Built-in Direct Vent Stove 

 

Natural Gas or Propane 

 

Residential or Mobile Home 

 

This appliance may be installed in an aftermarket, permanently located, manufactured home 
(USA only) or mobile home, where not prohibited by local codes. 
This appliance is only for use with the type of gas indicated on the rating plate.  A conversion 
kit is supplied with the appliance. 

 

INSTALLER: Leave this manual with the appliance.  
CONSUMER: Retain this manual for future reference.

 

French language manuals at travisindustries.com 

Manuels de langue Française à travisindustries.com

 

 

Travis Industries, Inc. 

12521 Harbour Reach Dr., Mukilteo, WA  98275 

www.travisproducts.com

 

 Copyright 2016, T.I.  

$10.00        10/2/17 

100-01454 

  

Содержание Berkshire MV

Страница 1: ...A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at risk individuals Tested and...

Страница 2: ...Insert has the same serial number as yours The serial number is attached to the appliance near the gas control valve This serial number will be needed in case you require service of any type Model Ber...

Страница 3: ...mination with Two Elbows one 90 vertical and one 90 or 45 horizontal elbow 16 Horizontal Termination with Three 90 Elbows all vertical 17 Vertical Terminations with Two 90 Elbows 18 Vertical Terminati...

Страница 4: ...talled in Manufactured Housing only after the home is site located All exhaust gases must be vented outside the structure of the living area Combustion air is drawn from outside the living area struct...

Страница 5: ...as main shutoff valve is usually next to the gas meter or propane tank and requires a wrench to shut off A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this...

Страница 6: ...ome s floor plan degree of insulation and the outside temperature Dimensions Electrical Specifications for optional blower Electrical Rating 115 Volts 1 5 Amps 60 Hz 180 watt Fuel This heater is shipp...

Страница 7: ...ble the Standard for Manufactured Home Installations ANSI NCSBCS A225 1 This appliance may be installed in Manufactured Housing only after the home is site located The heater is designed to operate on...

Страница 8: ...rom the paint curing and oil burning off the steel may occur the first time you start this heater This is normal We recommend you open windows to vent the room Stove Clearances Mobile Home Requirement...

Страница 9: ...e placed so the vents below or above the door along the sides of heater or along the back of the heater can become blocked This heater may be placed in a bedroom Please be aware of the large amount of...

Страница 10: ...sure all wiring is secure and does not contact hot or moving components The wall switch or thermostat may bypass the fireplace on off switch or be installed in parallel or series configuration see bel...

Страница 11: ...ation of the gas inlet is shown below A manual shutoff valve is required for installation it must be located within 3 915mm of the heater T Handle gas cocks are required in Massachusetts in compliance...

Страница 12: ...tly with just an air shutter adjustment Approved Vent Use 6 5 8 168mm diameter Simpson Dura Vent Direct Vent Pro or GS Other vent may be approved with this stove Check with the vent manufacturer for d...

Страница 13: ...e it aside To Access the Restrictor To Adjust the Restrictor NOTE The restrictor is shipped in position 1 Remove the screw a Slide the restrictor adjustment rod out b Replace the screw through the cor...

Страница 14: ...position 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 25 feet 7 5m 30 feet 9m 0 feet 40 max 12m 5 feet 1 5m 0 feet 0 feet 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 25 feet 7 5m 30 feet 9m 40 ma...

Страница 15: ...5 feet 1 5m 10 feet 3m 15 feet 4 5m 19 max 5 8m 0 feet 5 feet 1 5m 0 feet 0 feet 5 feet 1 5m 10 feet 3m 15 feet 4 5m Restrictor Position 5 NOTE Restrictor positions are based upon lab tests The ideal...

Страница 16: ...ted restrictor position 5 feet 1 5m 10 feet 3m 15 feet 4 5m 19 max 5 8m 0 feet 5 feet 1 5m 0 feet 0 feet 5 feet 1 5m 10 feet 3m 15 feet 4 5m Restrictor Position 5 NOTE Restrictor positions are based u...

Страница 17: ...on 5 feet 1 5m 10 min 3m 15 feet 4 5m 21 max 6 4m 0 feet 5 feet 1 5m 0 feet 0 feet 5 feet 1 5m 10 min 3m 15 feet 4 5m Restrictor Position 5 NOTE Restrictor positions are based upon lab tests The ideal...

Страница 18: ...4 5m 20 feet 6m 25 feet 7 5m 30 feet 9m 40 max 12m Restrictor Position 5 NOTE Restrictor positions are based upon lab tests The ideal restrictor position may vary slightly especially when the terminat...

Страница 19: ...eet 9m 0 feet 40 max 12m 5 feet 1 5m 0 feet 0 feet 5 feet 1 5m 10 feet 3m 15 feet 4 5m 20 feet 6m 25 feet 7 5m 30 feet 9m 40 max 12m Restrictor Position 5 NOTE Restrictor positions are based upon lab...

Страница 20: ...d the requirements of the gas supplier G Minimum 48 1219mm clearance from any adjacent building H Minimum 84 2134mm clearance above any grade when adjacent to public walkways or driveways NOTE may not...

Страница 21: ...talbestos 6 I D Security Chimneys 6 I D Jackes Evans 6 I D Hart Cooley 6 I D Pro Jet 6 I D Chimney Conversion Kit B 932 Simpson Dura Vent 6 I D Air Jet 6 I D Metal Fab 6 and 7 I D Amer Metals 6 7 I D...

Страница 22: ...d use the equipment listed in the illustration below to install this appliance into an interior masonry chimney Maximum vertical rise is 40 12M Minimum vertical rise is 10 3M See the chart on page 18...

Страница 23: ...njury If using propane LP convert the appliance before installing the media see page 40 The burner must be correctly positioned before installing the media Make sure the burner is fully seated and the...

Страница 24: ...Berkshire MV 3 The left log has two holes on the bottom Place the log so the holes fit over the two mounting studs on the left log stand 4 The right log has two holes on the bottom Place the log so th...

Страница 25: ...Place the log so the hole fits over the left pin on the rear log The front of the log rests on the left log see picture for orientation 6 The right cross log has one hole on the bottom Place the log s...

Страница 26: ...est method for applying the rock wool is to brush it on to the burner Compress a clump of rockwool between your thumb and forefinger Use a stiff brush to apply a thin layer of rockwool fibers onto the...

Страница 27: ...alve Turn the gas control knob to OFF to shut off the appliance 5 Install firebacks if applicable Install the log set page 23 6 Start the pilot see instructions on page 32 Check the pilot flame follow...

Страница 28: ...t contact the top of the firebox Check the flame on low position The flames should burn off of each burner hole If the heater does not work correctly contact your Travis dealer for a remedy 12 Give th...

Страница 29: ...OTE The metal tabs on the stove front slide over the tabs on the side castings Lift the stove top off the stove and place it aside a Re Attaching the Glass Frame a Slide the two brackets on the bottom...

Страница 30: ...disengaged Follow the directions below to re install the latch if it becomes loose Top of Firebox Hold the latch at an angle and insert it into the slot on the glass frame anchor NOTE this slot may b...

Страница 31: ...qualified service person Location of Controls See explanation below Optional Blower Control This knob controls the speed of the optional internal convection blower that pushes heated air into the room...

Страница 32: ...inutes to let any gas that may have accumulated inside the firebox escape If you smell leaking gas follow the directions on the cover IF YOU SMELL GAS c Turn the gas control knob to the PILOT position...

Страница 33: ...combustible items on top of or directly in front of the heater even temporarily The optional thermostat may start the heater causing a combustible item to ignite If the heater turns on and off frequen...

Страница 34: ...will work if household current AC power is disconnected OFF Turn the dial all the way counter clockwise until it clicks off HIGH The high position is all the way counter clockwise without clicking of...

Страница 35: ...me It should touch approximately 3 8 of the top of the flame sensor If it does not contact your dealer for service 2 Shut off gas to the heater and let it cool for 15 minutes Remove the glass see page...

Страница 36: ...er The remote control receiver is turned Off Remote or receiver batteries are dead See Starting the Pilot Light See Starting the Pilot Light Turn the ON OFF switch to ON Use the remote closer to the h...

Страница 37: ...SCREEN BARRIER SIDE x1 250 03420 PIEZO IGNITER w RETAINING NUT 250 00390 THERMO COUPLE 250 04383 THERMOPILE 250 04380 VALVE NG w MAN SIT 820 644 250 04377 Contact your local Travis Industries Dealer t...

Страница 38: ...8 Safety Label Travis Industries 10 2 17 1454 Berkshire MV Safety Label The safety listing label is attached to the operating tag chained to the heater near the gas control valve A copy is shown below...

Страница 39: ...gs of components lack of proper and regular maintenance damage incurred while the appliance is in transit alteration or act of God 8 This 7 Year warranty excludes damage caused by normal wear and tear...

Страница 40: ...ausing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operati...

Страница 41: ...Install the LP propane orifice a b Natural Gas Orifice 020N LP Propane Orifce 014LP 020N or 018N 014LP 7 16 Wrench 1 2 Wrench Use a 9 16 wrench to secure the manifold while removing the orifice with a...

Страница 42: ...ying correct operation remove glass bleed gas line leak test gas connections start the heater inspect pilot flame adjust air shutter and inspect burner performance Verify gas output pressure manifold...

Страница 43: ...only 43 Travis Industries 10 2 17 1454 Berkshire MV Optional Blower Installation WARNING Do not plug the blower in until it is fully installed and grounded Do not connect 110 120 VAC to the gas contr...

Страница 44: ...Options 6 Installation Overview 7 Installation Warnings 7 Interior Masonry Chimney Conversions 22 Location of Controls 31 Log Installation 23 LP Conversion Instructions 41 Maintaining Your Heater s Ap...

Отзывы: