13
5. Operating the Viper nt
E S C
F 1 2
.
Adjusting of the fog time
in seconds (1-99)
Escape to switch back to the
Standard-Menue with the Enter-button
5.5 Operating the internal timer
With the internal timer the „fog time” and ”wait time” as well as the output can be
adjusted.
To start the Timer-Mode, press and hold the Mode-button [14] for more than 2 seconds.
The red Timer-LED [19] shines as soon as the machine has switched to the Timer-Mode.
As long as the timer is in operation, the red Timer-LED blinks.
The adjusting of the output, fog time or wait time is the same as in the Standard-
Menu. That means you have to press the Mode-button until you reach the required
function.
With the Up/Down-buttons you can adjust the output (Pxx), fog time (F.xx) and wait
time (P.xx), then press the Enter-button to start the timer.
The timer cycle starts with the time last shown on the display (i. e. P.xx = Starts with
wait time, F.xx = Starts with fog time).
You can switch back to the Standard-Menu by pressing the Mode-button [14] for more
than 2 seconds or by switching to „ESC” (Escape) in the Timer-Mode and then press
the Enter-button.
5.5.1 Auto start
If the timer is in operation and you disconnect the machine from the mains cable, the
Viper nt
will re-start in the Timer-Mode as soon as it‘s reconnected to the mains. To
stop this press and hold the Mode-button [14] for more than 2 seconds or switch to
„ESC“ in the Timer-Mode and then press the Enter-button.