6. Cleaning, Care and Maintenance
– Remove the filter, which protects the fan against dust and dirt, from time to
time and clean it.
– After several hours of operation, some droplets of condensation will have
formed at the nozzle. That is normal and not a malfunction.
Please note
: Remove fluid droplets at the nozzle only when the machine has
completely cooled off. During operation the nozzle gets very hot!
– Do not let the
Unique
2
run without any fluid as the pump will run dry.
– Check the state of the fluid filter [12] from time to time and clean or replace it
when necessary.
–
PLEASE NOTE
: The vaporizer of our machines does not have to be cleaned!
Cleaners, available on the market, can damage the vaporizer! We cannot grant
warranty in this case.
Trouble:
The pump runs, but little or no haze is produced.
Cause:
The pump sucks no or too little fluid.
· Check whether the canister is empty
· Check whether the brass collar is properly connected with the brass
coupling
· Check whether the fluid filter in the canister is clogged
· Check whether the fluid tube is twisted or defective
Trouble:
The yellow LED at the machine does not light up (when running
via DMX)
Cause:
Connection from the machine to the desk is faulty.
· Check whether the plug is plugged in correctly
· Check whether the cable is defective
· Check whether the DMX start address is adjusted correctly
Trouble:
During operation the
Unique
2
fails to work for a long time
Cause:
The overtemperature protection device is activated.
· Check whether the fan is clogged