12
5.4.2 0 - 10 Volt (+) DC control
a) Put the cable from the desk or the cable remote into the XLR socket at the
back of the machine [3].
b) Put the pump up to 99% and adjust the required fan output at the machine
(see chapter 5.4.2.1).
c) With the rotary control on the cable remote or with the fader on the analog
desk the pump output can be regulated.
d) Pressing the On/Off switch at the cable remote starts the haze process. The
green Active-LED [18] will be lit.
Connect the
Unique
2
to an analog desk or the cable remote which you can get
as an option, using the XLR socket at the back of the machine [3].
Please note
: With analog control the pump can be adjusted from the desk and/
or the cable remote. The fan has to be adjusted at the machine.
5.4.2.1 Adjusting the pump and fan output
a) Press the Mode button [14] at the control panel until a P and two figures
appear on the LED display [17] (see Fig. 1). Put the pump up to 99%.
b) Press the Mode button [14] at the control panel until an F and two figures
appear on the LED display [17] (see Fig. 2).
c) Adjust the desired data (1 - 99%) by pressing the Up or Down button [15].
d) The data for the pump can be regulated/adjusted via the rotary control on the
cable remote and the fader on your analog desk.
5. Operating the Unique
2
5.4.1.2 Adjusting the pump and fan output
If you run the machine via a DMX desk you can adjust the pump and the fan
directly from the desk from 1 to 99%.
If you change the DMX start address, the newly selected channel controls the
pump and the next channel controls the fan.
b) Adjust the required start address by pressing the Up or Down button [15].
c) Save the start address by pressing the Enter button [16] once. The start address
will now also be saved when you disconnect the machine from the mains supply.