LRF-3300S Ultrasonic Transit-time Flow meter
- 28 -
that are not included in previous ten items. Once the
"Other" is selected, the relevant liner sound velocity
must be entered.
Use
and
to switch.
M13
Transducer
Select transducer type
The following options are available:
0.
Clamp-On
1.
Clamp-On S
2.
Clamp-On X
3.
Plus-In
4.
Plus-In X
Select transducer Mounting Methods
Three mounting methods are available:
0. V Reflect method
1. Z Direct method
2. N
M14
Installation space
This value is calculated by the flow meter
The operator must mount the transducer
according to the transducer spacing displayed
(ensure that the transducer spacing is measured
precisely during installation). The system will
display the data automatically after the pipe
parameter had been entered.
M20
Damping
The damping factor ranges from 1 ~ 999 seconds.1
indicates no damping; 999 indicates the maximum
damping.
The damping function will stabilize the flow display.
Usually a damping factor of 3 to 10 is recommended
in applications.
M21
Option
0.Clamp-On
M13
Transducer
*R
Type
Method
Option
M13
Transducer
*R
0.V
Type
Method
M14
INSTL Spacing
*R
Value
20.0
mm
Value
6
M20
Damping
*R