Longrun LRF-3000S Скачать руководство пользователя страница 32

                                                                                                                           

LRF-3000S Ultrasonic Transit-time Flow meter 

- 31 - 

 

conditions  when  it  is  not  preferable  to  use  other 
methods.  Enter  the  value  manually  to  add  to  the 
measured  value  to  obtain  the  actual  value.  For 
example:   

Actual measured value 

240 m

3

/H 

Value Deviation 

10 m

3

/H   

Flow meter Display 

250 m

3

/H 

Normally, set the value as "0". 

Use “

” and “

” to switch. 

 

 

 

M23 

Totalizer   

Select the totalizer type   

0.

 

POS    Positive Totalizer 

1.

 

NEG    Negative Totalizer 

2.

 

NET 

Select energy type   

0.

 

Heat   

1.

 

Cool 

Select "ON"/"OFF" to switch the totalizer. 

 

Select the flow    totalizer value you want Reset   

0.

 

POS    Positive Totalizer 

1.

 

NEG 

2.

 

NET    Negative Totalizer 

3.

 

All 

Select the energy totalizer value you want Reset   

0.

 

Heat   

1.

 

Cool 

2.

 

All 

 

 

 

 

M24 

0.0

m

3

/h

M22

Zero Settings

*R

Cutoff

Reset

Offset

Value

 

 

 

 

 

 

 

 

Energy

0.Heat

0.ON

Switch

Reset

Flow

0.POS

0.ON

M23

Totalizer

*R

 

 

Energy

0.Heat

Switch

Reset

Flow

0.POS

M23

Totalizer

*R

 

 

 

 

Содержание LRF-3000S

Страница 1: ...LRF 3000S Ultrasonic Transit time Flow meter Revision 1 0 0 UpdateRecord October 2018...

Страница 2: ...avoiding the damage to the flow meter or improper use Warning May cause injury Attention May damage the flow meter Some of the instructions may be different to the flow meters you purchased depending...

Страница 3: ...9 3 2 Measurement Site Selection 10 4 Transducer Installation 13 4 1 Transducer Installation 13 4 1 1 Transducer Spacing 13 1 1 2 Transducer Mounting Methods 13 4 1 3 V Method 13 4 1 4 Z Method 14 4...

Страница 4: ...cations Protocol 46 8 1 Overview 46 8 2 Serial port definitions 46 8 3 Direct connection via RS232 to the host device 47 8 4 Communications protocol and the use 47 8 4 1 HL Protocol 47 8 4 2 MODBUS I...

Страница 5: ...ess output signals etc can be conveniently entered via the windows British and Metric measurement units are available 3 Daily monthly and yearly totalized flow Totalized flow for the last 64 days and...

Страница 6: ...stable Relay output max Frequency 1Hz 1A 125VAC or 2A 30VDC Communication Interface RS232 RS485 SD Card Option Max record 512 days Record time interval 1 3600 s Power Supply 10 36 VDC AC90 245V Keypad...

Страница 7: ...has been installed the flow meter wiring can be connected Open the case you will find the Power board wiring ports from left to right are as follows Connect to power supplier Relay Output OCT Output T...

Страница 8: ...meter is switched on the system will run automatically according to the last input parameters If the installation is accomplished when system is switched on gain adjustment can be monitored in Window...

Страница 9: ...code has a defined meaning For example Window M10 indicates the parameter input for pipe outside diameter while Window M14 indicates the mounting spacing between the transducers etc Refer Windows Disp...

Страница 10: ...ind M10 enter the pipe size the outer diameter of the pipe and the pipe thickness Press the Enter to confirm OD 200 0 mm M10 Pipe settings R Size M thk 4 0 mm Step2 Pipe Material Use to switch to sele...

Страница 11: ...selected mounting method M14 INSTL Spacing R Value 154 2 mm Step 7 Display Measurement Results Menu 01 will display flow rate Subject to the real measurement M01 Flow Rate R Flow Vel 100 2 m3 h 3 2 M...

Страница 12: ...s installation On the horizontal pipe the transducer should be mounted on the 9 and 3 of the pipe avoiding the position of 6 and 12 in case of the signal attenuation caused by pipe at the bottom sedim...

Страница 13: ...LRF 3000S Ultrasonic Transit time Flow meter 12...

Страница 14: ...he top portion of the pipe Refer to Transducer Mounting If the transducers cannot be mounted horizontally symmetrically due to limitation of the local installation conditions it may be necessary to mo...

Страница 15: ...s is because the Z method utilizes a directly transmitted rather than reflected signaling which transverses the liquid only once The Z method is able to measure on pipe diameters ranging from 100mm to...

Страница 16: ...sted and the pipe should be re inspected If necessary change the mounting method to be Z method 4 2 2 Signal Quality Q value Q value is short for Signal Quality displayed in Window M04 It indicates th...

Страница 17: ...ignal detected Thus it is necessary to check that the parameters including all the pipe parameters have been entered accurately Check to be sure the transducer mounting method has been selected proper...

Страница 18: ...Zero is too big that indicates the quality of the instrument is poor If the zero set point is not at true zero flow a measurement difference may occur The smaller the physical measurement capacity is...

Страница 19: ...perL When flow direction is an issue module 0 4 20mA is available When the flow direction displays as negative the current output is in range of 0 4mA whereas the 4 20mA is for the positive direction...

Страница 20: ...he flow ranges using the software alarm system There are two software alarms Alarm 1 and Alarm 2 Example 1 When flow rate exceeds 300 1000 m3 h in order to program the relay output alarm Complete the...

Страница 21: ...tive totalizer Data storage format a 2017 11 16 16 21 12 b 2 652471E 00 m3 h c 9 380460E 02 m s d 3 520580E 02 m3 e 3 520580E 02 m3 f 0 000000E 00 m3 g 0 000000E 00 GJ h h 0 000000E 00 GJ i 0 000000E...

Страница 22: ...to view in Window M50 ATTENTION Other Operating Refer to 6 2 Window Display Explanations Attention Do not remove the SD card from the reader while actively working with the data Data should be saved a...

Страница 23: ...M01 Flow Rate M02 Hot M03 Cool M04 Status M1X Installation Setting M10 Pipe Settings M11 Lining Settings M12 Liquid Settings M13 Transducer Settings M14 Installation Space M2X Calibration Setting M20...

Страница 24: ...on M4X Flow Unit Opinions M40 Toggle Units M41 Flow Units M42 Energy Units M43 Temperature Units M5X System Settings M50 Serial Number M51 Time and Date M52 Key Ton M53 Language M54 System Lock M55 Sy...

Страница 25: ...e totalizer Use and to switch M01 Flow Rate Display the Flow Rate and Flow Total Display the Velocity Flow Rate and the Flow Total switch every 6 seconds Use the ENTER to stop the switch M02 M00 Flow...

Страница 26: ...witch every 6 seconds Use the ENTER to stop the switch M03 Cool Rate Display the Cool Total Display the Cool Rate and the Inlet Water Temp and Outlet Water Temp NOTE Instrument needs energy capacity x...

Страница 27: ...should be 100 3 If the difference is too large the user should check that the parameters are entered correctly especially the sound velocity of the fluid and the installation of the transducers This...

Страница 28: ...Iron Pipe 5 Copper 6 Alu Aluminum pipe 7 ACP Asbestos Cement Pipe 8 FPG Fiberglass Pipe 9 Other It is possible to enter other materials which are not included in previous eight items Once item 9 is s...

Страница 29: ...l 6 PS Polystyrene 7 Polyester 8 PE Polyethylene 9 Ebonite 10 Teflon 11 Other Item 11 Other is available to enter other materials that are not included in previous ten items Once the Other is selected...

Страница 30: ...ct method 2 N M14 Installation space This value is calculated by the flow meter The operator must mount the transducer according to the transducer spacing displayed ensure that the transducer spacing...

Страница 31: ...ue is called Zero Point When Zero Point is not at zero in the flow meter the difference is going to be added into the actual flow values and measurement differences will occur in the flow meter Set ze...

Страница 32: ...ch M23 Totalizer Select the totalizer type 0 POS Positive Totalizer 1 NEG Negative Totalizer 2 NET Select energy type 0 Heat 1 Cool Select ON OFF to switch the totalizer Select the flow totalizer valu...

Страница 33: ...the function of power down automation correction switch the flow lost in an offline session can be estimated and automatically adjusted The estimate is based on the average value which is obtained fr...

Страница 34: ...Open the Sectional Correction Function OFF Close the Sectional Correction Function Delay correction Engineer menu suggest customer use the factory setting TPC Transducers power control Engineer menu...

Страница 35: ...9600 None 3 19200 None 4 38400 None 5 56000 None M31 AI Setting Display analog input AI1 analog value Display analog input AI2 analog value M28 SQA R Option 0 ON 1 OFF Set Value 4 500 Reset M28 SQA R...

Страница 36: ...0MA Set the CL output value according to the flow value at 20mA 4 20mA check opinions a Check 4mA b Check 8mA c Check 12mA d Check 20mA M33 OCT Setting LowerL 1 0 UpperL 1000 0 M31 AI Settings R AI1 A...

Страница 37: ...h Rationing i Uart CTRL Select the OCT Range value OCT check opinions a Check 500 b Check 1000 c Check 3000 d Check 5000 M34 Relay Setting The following signal options are available Option a Flow Rate...

Страница 38: ...than the low value will activate the alarm in the OCT hardware or relay output signal Enter the Upper alarm value any of the measured flow which is higher than the high value will activate the alarm...

Страница 39: ...ption M40 Toggle Unit Select the measurement unit as follows a Metric b British M41 Flow Unit The following flow rate units are available 0 Cubic Meters m3 1 Liters 1 2 USA Gallons GAL 3 Imperial Gall...

Страница 40: ...Energy Unit The following Energy units are available 0 Giga Joule GJ 1 Kilocalorie Kc 2 MBtu 3 KJ 4 Btu 5 KWh 6 MWh 7 TH a x 0 001 E 3 b x 0 01 E 2 c x 0 1 E 1 d x 1 E 0 e x 10 E 1 f x 100 E 2 g x 10...

Страница 41: ...uses it for files setup and for management by the user SVN is the software version M51 Time and Data Date and time modifications are made in this menu M52 Key Tone Use this menu to ON OFF the key ton...

Страница 42: ...System Reset Select 1 Reset to make the instrument back to factory M60 Date Totalizer The following options are available 0 Day 1 Month 2 Year In this window it is possible to review the historical f...

Страница 43: ...he pass word to adjust M64 RTD Adjust This menu is for the AI calibration enter the pass word to adjust Value 5 Day M61 Running Time R 4mA Enter to go 20mA Enter to go M62 CL Adjust R 0 C Enter to go...

Страница 44: ...LRF 3000S Ultrasonic Transit time Flow meter 43 AI1 AI2 M64 AI adjust R 20mA Enter to go 4mA Enter to go AI1 AI2 M64 AI adjust R 20mA Enter to go 4mA Enter to go...

Страница 45: ...entative for assistance 7 1 Table 1 Error Codes and Solutions during operation Codes The upper right corner of the screen Causes Solutions R System Normal System normal E Signal Not Detected Signal no...

Страница 46: ...ly Slowly and slightly move each transducer with respect to each other around the installation point until the maximum signal is detected Be careful that the new installation location is free of scale...

Страница 47: ...length 0 1000m can be directly used for data transmission links for a short distance Current loop can be used in medium or long distance transmission When the flow meter is used in a network environm...

Страница 48: ...baud rate of asynchronous communication Primary station computer system Secondary station ultrasonic flow meter is generally 9600BPS A single byte data format 10 bits one start bit one stop bit and 8...

Страница 49: ...Return Relay Status ON OFF cr RDT cr lf Current date and time yy mm dd hh mm ss cr RSN cr lf Return serial number dddddddt cr Note 4 SFQdddd d cr lf OCT setting dddd d cr Successful setting will back...

Страница 50: ...and P commands can be used in combination for example W123PRT which means that the instrument that reads the network address is the cumulative value of the instrument with 123 and its return data has...

Страница 51: ...s at the beginning while the high byte is at the end For example to read the address 1 0x01 in the RTU mode if the instantaneous flow rate uses hour as a unit m3 h namely reads 40005 and 40006 registe...

Страница 52: ...code is 0x01 0x83 0x02 0xC0 0xF1 Flow meter Address Error Code Error Extended Code CRC Verify Code 5 MODBUS Register Address List The flow meter MODBUS Register has a read register and a write single...

Страница 53: ...l hot exponent 16 bits int 1 0016 40023 Energy total cold high word 32 bits real 2 0017 40024 Energy total cold exponent 0018 40025 Energy total cold exponent 16 bits int 1 0019 40026 Up signal int lo...

Страница 54: ...l number char 7 8 0049 40074 Analog Input AI1 Value low word 32 bits real 2 Returned temperature value with RTD option 004a 40075 Analog Input AI1 Value high word 004b 40076 Analog Input AI2 Value low...

Страница 55: ...5 cf Cubic Feet 6 ba US Barrels 7 ib Imperial Barrels 8 ob Oil Barrels 2 The following energy units are available 0 GJ Giga Joule 1 Kc Kilocalorie 2 MB MBtu 3 KJ Kilojoule 4 Bt Btu 5 Ts US Tonnes 6 T...

Страница 56: ...d Pipe Material Sound Velocity m s Steel 3206 ABS 2286 Aluminum 3048 Brass 2270 Cast iron 2460 Bronze 2270 Fiber glass epoxy 3430 Glass 3276 Polyethylene 1950 PVC 2540 Liner Material Sound Velocity Te...

Страница 57: ...0 1554 4 13 1458 7 47 1538 9 81 1554 2 14 1462 3 48 1540 2 82 1553 9 15 1465 8 49 1541 3 83 1553 6 16 1469 3 50 1542 5 84 1553 2 17 1472 7 51 1543 5 85 1552 8 18 1476 0 52 1544 6 86 1552 4 19 1479 1 5...

Страница 58: ...sit time Flow meter 57 Longrun Industrial Instrument Co Ltd 24hours service 86 186 5435 6933 Tel 86 543 3382666 Fax 86 543 3615999 E mail info ultrasonicscn com Website www longrun flowmeter com This...

Отзывы: