![Longrun LRF-3000S Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/longrun/lrf-3000s/lrf-3000s_user-manual_1938702010.webp)
LRF-3000S Ultrasonic Transit-time Flow meter
- 9 -
3.
Quick start
3.1.
Basic settings
For example, let us you have a pipe of 200mm outer diameter
、
4mm pipe thickness, measuring medium is water,
Pipe Material is PVC with no Liner, These parameters should be operated as follows:
Step1. Pipe Size Settings
Find M10; enter the pipe size, the outer diameter of
the pipe and the pipe thickness.
Press the “ Enter” to confirm.
OD
200.0
mm
M10
Pipe settings
*R
Size
M.
thk
4.0
mm
Step2. Pipe Material
Use “
” to switch to select the material of the
pipe.
Press the “ Enter” to confirm.
Size
M.
M10
Pipe settings
*R
Other
3200
m/s
M.
0.PVC
Step 3. Water Temperature
Find M12, select the temperature of the water,
temperature should be 0-80 deg. C.
Press the “ Enter” to confirm.
Note: Room temperature is 25 deg.C
WTMP
20
(
。
C)
M12
Medium
*R