6
Troubleshooting
6.1
Motor does not start after turning on.
1.
Battery out of power?
Charge and try again.
2.
Loose power cables?
Disconnect battery, open the base, and firmly con-
nect any wires.
3.
Hot weather?
The motor may have overheated, activating the protective
breaker. Try again in cooler weather.
4.
Broken power switch?
Replace.
6.2
Motor starts, but sounds abnormal.
1.
Look for loose pump screws.
Tighten.
6.3
No spray.
1.
Check nozzle for clog.
2.
Check hose for leaks.
There may be air in the hose.
3.
Check pump for clog.
Remove any debris.
6.4
Sprays, but low flow rate or pressure.
1.
Check intake filter for clog.
2.
Not enough power?
Charge the battery.
6.5
There is a leak.
1. Check for damaged or missing O-rings.
2. Tighten connections.
3. If the hose is leaking due to damage, replace the hose.
6.6
Motor continues to run after trigger released.
1.
Check for pump cover leak.
Tighten the pump cover.
2.
Check for other leaks.
6.7
Leak at base of unit.
1. Open the base of the unit and tighten the inlet/outlet tube connections.
6
Содержание MistGen MG-SB16
Страница 9: ...7 Schematic and replacement parts 8...
Страница 10: ...9...