![LONCIN G120F Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/loncin/g120f/g120f_shop-manual_1938401057.webp)
G120F/G160F/G200F Part IV Disassembly and maintenance
- 56 -
d) If the clearance exceeds the service limit, replace
the connecting rod and recheck the clearance. if the
clearance after installing the new connecting still
exceeds the service limit, ap the neck journal
and use a connecting rod lower than the standard
value.
Inspection of camshaft
As the main driving part of the gasoline engine
’
s valve
actuating mechanism, the camshaft controls the intake
and exhaust valves
’
opening and closing following a
certain principle. Visually check the cam surface and
cam height for any damage, and check whether bearings
and camshaft are loose or worn, if so, replace them all.
1) Cam height
Standard
Service limit
IN
27.7mm
27.45 mm
EX
27.75mm
27.50 mm
2) Camshaft O.D.
Standard
Service limit
13.984mm
13.916mm
Plastic gauge