INSTALLATION: 
1. Determine the install location of the Lomanco Model BRV34 roof 

jack. Comply with all local codes and standards. 

2. Cut a 5” diameter hole in the roof to adequately accommodate 

the ductwork diameter.

3. Connect the 4” duct connector. 

Insert the V cut on the duct 

connector into and under the 

notch in the bottom of the roof 

jack. Rotate the duct connector 

one full revolution until it is 

completely engaged. (Figure 2)

4. Insert duct connector/roof jack 

assembly into the hole, position 

and center the roof jack within 

the hole  and mark the outline 

of the flange. (Figure 3)

5. Cut shingles as shown 

allowing the shingles to 

fit around the housing 

of the roof jack when 

installed. Apply roofing 

cement to seal around 

the ductwork as shown. 

(Figure 4)

6. Connect one end of 

the flexible duct  over 

the duct connector and 

secure with the supplied 

hose tie.

7. Carefully slide the base of the roof jack under the shingles with 

the screened opening pointing down towards the roof eave. Note 

that some nails may have to be raised or removed to allow the 

adapter to slide into place. Fasten the base to the roof decking 

with roofing nails located as shown. (Figure 5)

8. Finish by sealing all seams and nails with roofing cement. Also 

use roofing cement to fasten down loose edges of shingles. Make 

certain the pest screen is in place.

Note: For best exhaust performance use the shortest run of flexible 

duct as possible. If the 8-foot length is more than required, cut duct 

to desired length.
9. Connect free end of flexible duct  to the fan output collar and 

secure with the supplied hose tie.

Note: If discharge  collar on fan is 3” diameter, use the neoprene 

strip to increase the diameter to 4”. 

To install the neoprene strip: 

center it on top of 

the output collar. 

Remove the paper 

backing. 

Smoothly wrap 

it around the 

output collar so the 

adhesive holds it in 

place.

BATH PRO

TM

 KIT 

Installation Instructions

IMPORTANT! 

• 

Installation of Lomanco Vents should comply with all local codes and standards. 

• 

Do not install roof jack on a flat roof.

• 

Do not use roof jack on a dryer exhaust vent.

• 

WARNING! Sharp edges are exposed during installation. Use gloves and other 

appropriate safety equipment to avoid injury. 

LOMANCO 

BATH PRO

TM  

KIT

KIT INCLUDES:

4” DUCT CONNECTOR

8’ OF 4” FLEXIBLE DUCT

BRV34 ROOF JACK

NEOPRENE STRIP

2 - HOSE TIES

MODEL BRV34KIT

Color Note: The black painted finish 

of the BRV34 can be used as-is or as a 

primer coat for a color finish of your 

choice. Clean the surface of all dirt, 

grease and oil before applying a color 

finish. Use a high quality finish to best 

serve the conditions of your application.

lmc_ch_0319

Figure 3 / Figura 3

23/4”

13/4”

13/4”

ROOFING 

CEMENT

Figure 4 / Figura 4

Roof Jack 

OUTLINE

CONTORNO de la 

cubierta para el techo

CONTOUR de la buse de toit

CUT AREA

ÁREA DE CORTE
ZONE DE COUPE

CEMENTO PARA TECHO

BITUME DE COLLAGE

7cm (2,75 po)

4.45cm (1,75 po)

4.45cm (1,75 po)

Figure 5 / Figura 5

BITUME DE COLLAGE

CEMENTO PARA TECHO

Roof Cement

NAILS

CLAVOS

CLOUS

Figure 2 / Figura 2

NOTCH

V-CUT

MUESCA

ENCOCHE

CORTE EN V

COUPE EN V

NEOPRENE 

STRIP

3” FAN 

EXHAUST

9”

TIRA DE NEOPRENO

BANDE DE NÉOPRÈNE

EXTRACTOR VENTILADOR DE 3”

VENTILATEUR D’EXTRACTION DE 7,5 CM (3 PO)

Figure 1 / Figura 1

FAN

HOSE TIE

CONNECTOR

ROOF JACK

FELXIBLE 

DUCT

3” TO 4” ADAPTER

VENTILADOR

VENTILATEUR

CONECTOR

RACCORD

AMARRE DE MANGUERA

ATTACHE DE TUYAU

ADAPTADOR DE 3” A 4”

ADAPTATEUR DE 7,5 À 10 CM (3 À 4 PO)

DUCTO FLEXIBLE

CONDUIT FLEXIBLE

RECEPTÁCULO DE TECHO

BUSE DE TOIT

Отзывы: