background image

Operator's Guide

5-2

Module 7005

INTRODUCTION TO 

SYSTEM CONTROL

Control of the LOMA Superscan Micro is easily achieved once the basic principles of operation are
understood. The following two pages show diagrams of the User Interface and of the Menu Map.
Certain keys on the User Interface control movement around the Menu Map such that any menu entry
can be reached quite simply from any other.

The Menu Map is organised into four logical groups: Setup, Change, Calibrate and Results. These
menus can all be accessed via the dedicated keys on the User Interface. To become completely
familiar with the operation of the LOMA Superscan Micro, it is necessary that the 

Operators Guide

Menu  Map is fully understood

. Spend some time now looking at the diagram of the Menu Map on

page 3 and observe some of the possible routes to perform frequent tasks.

Following a more complete description of the User Interface Menu Map is a Product Setup example
showing how to set the metal detector up for a new product. Use this example to gain familiarity with
the unit before attempting to operate the machine under production conditions.

Содержание Superscan Micro

Страница 1: ...Calibrate and Results These menus can all be accessed via the dedicated keys on the User Interface To become completely familiar with the operation of the LOMA Superscan Micro it is necessary that th...

Страница 2: ...Key Up Key Main Menu Keys Each of the four main menu keys has an LED which shows the main menu that is being accessed at any time Status LEDs The Run Detect LED indicates that the detector is searchin...

Страница 3: ...X PACK COUNT RESET BATCH STATUS REPORT RUN PV TEST T xxxxx S xxxxx LOCK KEYBOARD CHANGE SETUP CALIBRATE RESULTS SCROLL SELECTION KEYCODE 1234 CALENDAR SERVICE CHANGE 1234 PV TEST 1234 PRODUCT NO _ _ N...

Страница 4: ...note that an is shown on the display in which case go to step four If the display shows neither of these texts push the CANCEL key until it does and then go to step two or four depending upon the disp...

Страница 5: ...holds giving greater sensitivity and larger ones less sensitivity To adjust this threshold press the ENTER key The display will now show T 1000 SIG 255 Notice how the has moved to the left hand side o...

Страница 6: ...in access to the items within them The Disable Reject is in fact a command and as such is denoted with the character Within the Setup menu there are no items of data but if the Product Setup sub menu...

Страница 7: ...ing example Step One Suppose you with to alter the time of day say from 9 00am to 10 00am Use the keyboard as described above to move to the Hours parameter The display should show HOURS 9 Notice how...

Страница 8: ...f this is shown in the next section on how to set up a product for the first time where the Full Calibrate command is invoked To summarise Use the main menu keys to move into one of the four menus Use...

Страница 9: ...ou have calibrated the machine with a product which you believe has no product effect because it contains no moisture or conductive ingredients iron additives but the unit fails to achieve the desired...

Страница 10: ...Press the down key to move to the display PV TEST SETUP This menu only appears if the option is enabled via the OPTIONS menu PV TEST SETUP contain five system relative entries and four product relati...

Страница 11: ...icate that the product been changed and then return to the top of the menu map showing the product signal Refer to the Change menu in the A Z section for details of any warning messages given Recalibr...

Страница 12: ...the display indicates that the calibration cycle is complete Setting up a new product Press the SETUP key once Press the ENTER key twice Use the and keys to select the desired product number Press th...

Отзывы: