3.3.3 TIG Welding Fundamentals 

Stricking the arc for  TIG  Operation:  when tungsten electrode touches the workpiece, the short-
circuit current is only  28A . After generating arc,  current can rise to the setting welding current.  If 
the tungesten electrode touches the workpiece when welding, the current will drop to 5A 

 

  within 2s, 

which can reduce tungsten waste, prolong the using life of the tungsten

 

electrode, and prevent 

tungsten clipping. 

 

Scraping arc 

 

Tungsten Electrode Current Ranges 

Electrode Diameter 

DC Current 

1.0mm 

25 - 85 

1.6mm 

50 - 160 

2.4mm 

160 - 250 

3.2mm 

250 - 400 

4.0mm 

400 - 500 

 

Shielding Gas Selection 

Alloy 

Shielding Gas 

Carbon Steel 

Welding Argon 

Stainless Steel 

Welding Argon 

Nickel Alloy 

Welding Argon 

Copper 

Welding Argon 

Titanium 

Welding Argon 

 

Tungsten Electrode Types 

Electrode Type        

(Ground Finish) 

Welding Application 

Features 

Colour Code 

Thoriated 2% 

DC welding of mild steel, 

stainless steel and copper. 

Excellent arc starting, long life, 

high current carrying capacity. 

Red 

Ceriated 2% 

AC & DC welding of mild 

steel, stainless steel, copper 

aluminium magnesium and 

their alloys. 

Longer life, more stable arc, 

easier starting, wilder current 

range, narrower more concen-

trated arc. 

Grey 

 

Содержание GRAND ARC 400 CEL

Страница 1: ...nes IMPORTANT Read this OPERATOR MANUAL together with PRESCRIPTION AND COMPLIANCE MANUAL before to use this equipment In case of loss one of two parts contact immediately your dealer Allow the operato...

Страница 2: ...allation for MMA Welding 3 2 2 Operation for MMA Welding 3 2 3 MMA Welding 3 2 4 MMA Welding Fundamentals 3 2 5 MMA Welding trouble shooting 3 3 Installation Operation for TIG Welding 3 3 1 Set up ins...

Страница 3: ...nd receivers c computer and other control equipment d safety critical equipment for example guarding of industrial equipment e the health of the people around for example the use of pacemakers and hea...

Страница 4: ...tric shock by touching these metallic objects and the electrode at the same time The operator should be insulated from all such bonded metallic objects Earthing of the workpiece Where the workpiece is...

Страница 5: ...e applications Designed to work with diesel generators and to avoid failures due to its voltage spikes Power source wind tunnel cooling construction for protection against environmental contamination...

Страница 6: ...lly to protect the electro de While TIG operation the minimum current will be outputted firstly until the arc is ignited by lifting method the output current will rise to the preset value which can pr...

Страница 7: ...hile the welding current parameters can be adjusted continuously and steplessly to meet with the requirements of welding craft 2 6 Volt Ampere Characteristic MMA series of welding machines has excelle...

Страница 8: ...mode indicator 11 MMA VRD mode indicator 12 Lift TIG mode indicator 13 Arc Force control knob 14 Hot Start control knob Denotes more detailed explanation of function to follow Further Controls Explai...

Страница 9: ...ave a negative effect on the weld quality due to tungsten contamination Lift arc starting works by gently touching the tungsten on the work piece andthen lifting it off The contro l circuit will sense...

Страница 10: ...power switch so that the power switch is ON position then the power indicator light the fan comes on the device work properly 2 Select the MMA MMAVRDfunction with the LIFT TIG MMA MMA VRD selector sw...

Страница 11: ...ctrode rod or stick The electrode rod is made of a material that is compatible with the base material being welded and is covered with a flux tha t gives off gaseous vapours that serve as a shielding...

Страница 12: ...filler metal to the molten pool These additional functions are provided mainly by the covering on the electrode 3 2 4 MMA WeldingFundamentals Electrode Selection As a general rule the selection of an...

Страница 13: ...is to have an arc length no greater than the diameter of the core wire Electrode Size mm Current Range Amps 2 5 mm 60 95 3 2 mm 100 130 4 0 mm 130 165 5 0 mm 165 260 Electrode Angle The angle that th...

Страница 14: ...nt grease oil and dirt including mill scale from base metal Poor welding technique Use the correct welding technique or seek assistance for the correct technique 5 Lack of penetration Insufficient hea...

Страница 15: ...he fluctuation range 10 The power ground is well grounded NOTE When TIG operation the shielded gas is inputted to welding gun directly Secure the gas cylinder in an upright position by chaining them t...

Страница 16: ...Diameter DC Current 1 0mm 25 85 1 6mm 50 160 2 4mm 160 250 3 2mm 250 400 4 0mm 400 500 Shielding Gas Selection Alloy Shielding Gas Carbon Steel Welding Argon Stainless Steel Welding Argon Nickel Allo...

Страница 17: ...ct the torch to the DC output terminal Incorrect tungsten being used Check and change the tungsten type if necessary Tungsten being oxidised after weld is finished Keep shielding gas flowing 10 15 sec...

Страница 18: ...Tungsten incorrect or in poor condition Check that correct type of tungsten is being used Remove 10mm from the weld end of the tungsten and re sharpen the tungsten Poorly prepared tungsten Grind marks...

Страница 19: ...arc in unprotected eyes Ensure good ventilation of the machine to improve Duty Cycle Turn off the engine when the operation finished for energy consumption efficiency When power switch shuts off pro t...

Страница 20: ...e or overheated If the arc welding machine has the above problems it should be fastened or changed Observe whether the current output cable is damaged If it is damaged it should be insulated or change...

Страница 21: ...to cause sticking The plug loosen or connect not well Check and tighten the plug Oil or dust covered the workpiece Check and clear out Wrong mode selected Check the MMA selector switch is selected 7...

Страница 22: ...on E13 Under voltage Yellow lamp thermal protection always on E14 Over voltage Yellow lamp thermal protection always on E15 Over current Yellow lamp thermal protection always on E16 Wire feeder over l...

Страница 23: ...AC AC Vcc 0 Vcc Vc Vc PR2 iventer board PR1 control board Vc Vc FA MMA 250 T1 rectifier bridge K C1 condenser FA fan OT protection J4 T2 T3 T4 T5 IGBT moduler T6 T7 fast recovery diode B1 main transf...

Страница 24: ...LOKERMANN Srl Via Produzione 16 18 37044 Cologna Veneta VR Italy Tel 39 0442 1722469 lokermann lokermann eu www lokermann eu...

Отзывы: