Installation instruction                            stove KOMEN                                         Creina d.d.

3.1.6.

Fire-protection distances

Minimum distance between charging door 
and combustible objects must be at least 
80 cm, while for sideplates; the distance 
must be greater then 20 cm.  

3.1.7.

Chimney

Effective height of the chimney should be 
at least 4 meters (measured from the 
hearth of the stove). For detailed 
calculations, please refer to standard EN 
13384-2.

4. Transport

Transport should be handled by experts with 
appropriate equipment. 

4.1.

Packaging 

o

Stove it tightly fixed onto a palette.

o

Please check the stove for possible 
damages and that is contains all 
ordered parts. 

o

If you do find any damages, please 
report them to your stove supplier 
immediately.

4.2.

Handling of stove

 

o

Stoves should be moved with a palette, 
standing upside-down. Move it carefully 
so it does not tip over!

o

Avoid shocks and vibrations.

o

Once in place, dismount it and proceed 
with the installation.

o

When transporting, do not physically 
overload the top cover of the stove.

5.

General instructions (Air inlet is 
optional)

o

Please do not overload the stove. 

o

All the packing material should be removed
from hearth and ash pan. 

o

Check out functionality of movable parts 
(front door etc.)  

o

Build outer air flaps into facade  

o

Mount smoke flap onto chimney funnel 

o

Connect chimney funnel. Chimney 
thickness and insulation must be in 
accordance with country's and EU 
construction regulations. 

o

Chimney must not apply additional 
pressure on the stove.  

o

Minimum diameter of the chimney should 
be taken into consideration. 

o

Measured values, gathered in this 
document, corresponds to the calculations 
of chimney with the following dimensions - 
4 m height; diameter 150mm. 

5.1. Air supply connection

o

For stove to work properly, continuous 
air supply is required. 

o

If upper requirement is not met, 
additional air supply can be provided 
through air tube connection (Ø100mm)
(accessory), which is inserted at the 
back of the stove's pedestals onto the 
stove. 

o

Airflow is being regulated with air taps, 
which are built-in, into air supply 
conduit. These parts are not supplied 
with the stove, nor they are part of the 
stove.

o

Please note that during winter times, 
cold air surges can generate condense
on stove parts and thus compromise its
functionality. Don't expose stove to 
water.

6. Repair advice

o

Glass frame and most of the movable parts
can be removed once the stove is installed.

o

Repairs can only be performed by a 
professional in agreement with the 
supplier/manufacturer  

o

Repair instructions are not part of this 
document 

o

If necessary, refer to your local dealer of 
service agent. 

7. General warranty

For details on warranty, please look at the user 
manual.