Installation instruction                            stove KOMEN                                         Creina d.d.

2. Mounting instructions

2.1.

Foreword

Please read these instructions carefully and 
pay attention to general safety instructions..

Before you start with the installation, of the 
stove, check:

o

If all parts are included (Notify supplier if 
any of the parts are missing) 

o

The stove for potential damages (pay 
special attention to glass, fire door and 
coating protection; Notify hauler, if 
damages are found) 

o

The functionality of all the movable parts

This manual is not a service handbook. Here
you won't find any instructions on how to 
repair the stove.

2.2.

Regulations

Following regulations and standards have to 
be followed:

o

EN 13240

o

State building regulations and provisions.

o

Fire-protection provisions.

o

All other European, national and local 

regulations and provisions that deal with 
installation of the stove.

3. Basic requirements

3.1.

Installation area

3.1.1.

Stove can be installed if: 

o

Installation area is big enough to 
ensure safe and normal use 
(operating, cleaning …) of the stove.

o

Within radiation area of the stove, 
there are no load-bearing construction 
elements (ex. pillars). 

o

Sufficient air supply is secured. 

o

There is at least one door or window 
that leads out of the room where the 
stove is installed. 

o

There is a direct or indirect air 
connection with another room. . 

3.1.2.

Stove must not be installed:

o

In rooms, where highly inflammable 
and explosive substances or their 
mixtures are being manufactured, 
processed or stored.  

o

In rooms that are ventilated and have 
safety devices that prevent negative 
pressure.

o

In rooms that have no adequate air 
supply for stove to work properly.

3.1.3.

Installation requirements

o

Stove has to be installed in a way, that
connection parts (chimney flue, air 
conduit), when needed of cleaning, 
are easily accessible.

o

Walls in installation area of the stove, 
must be free of electrical and gas 
installations..

3.1.4.

Air combustion conduit

o

Air connection for additional air supply 
to the room, where stove will be 
installed, has to have a cross-section 
of at least 100 cm

2

.

o

Fresh air conduit has to have an inbuilt
closing flap, where positions »open« - 
»close«, must be clearly visible.

o

When calculating the necessary air 
conduit cross-section, local (elbows, 
filters etc.) and line (conduit length) 
resistances have to be taken into 
consideration.

o

When air travels through operating 
combustion chamber, it heats up.

o

Air conduit's overflow resistance must 
not exceed 4 Pa.  

3.1.5.

Floor protection 

o

If floor, where stove will be located, is 
not fire resistant, it has to be protected
by a layer of fire-resistant material (ex.
6 mm thick glass plate).

o

Area where the stove will be installed, 
must withstand the weight of the stove
and chimney.

o

Incombustible floor area in front of the 
stove has to be at least 50 cm long, 
while on the sides the distance must 
not be less then 20 cm. (measured 
from stove walls).