The Lohberger Pellet module was successfully tested by the Technical University 
of Vienna according to the current European Standards.
 

Test report number:

 TGM-VA HL 7813

The appliance is in conformance with the emission values according to art.15a 
B-VG (Austrian law) for protective measures and energy saving. Furthermore, 
amongst others the following exhaust gas limits according to the following 
German standards are complied with: Regensburger Norm, Stuttgarter Norm 
and Münchner Verordnung.

Table 4

AC 105

F3+B3

Fuel fi lling door opening

Width x height

mm

185 x 245

Fuel fi lling space  

Width x depth

mm

233 x 405

Fuel fi lling height

grate top /bottom position

mm

100 / 250

Oven

Width x height x depth

mm

420 x 290 x 410

Cooking surface 

Width x depth

mm

1008 x 507

Area

m

2

0,51

Ash drawer

Stove

litre

4,5

Fuel storage container 

Stove

litre

34,5

Fuel consumption

Heat output min./ max.

kg / h

2,3 / 3,8

Central heating insert

Water content

litre

25

Operating pressure 

Max.

bar

3

Operating temperature 

Max.

°C

95

Baking tray 

Width x depth

mm

400 x 400

Baking tray / Grid  

Width x depth

mm

400 x 400

Weight

packaging included

kg

 345

Packaging

kg

ca. 30 – 40

Output data:

Data for chimney calculation 

Rated heat output / Full fi ring

wood / lignite

kW

14 / 13,5

    Water heating capacity

wood / lignite

kW

10,5 / 9,5

    Room heating capacity

wood / lignite

kW

3,5 / 4

Rated heat output / Shallow fi ring

wood  

kW

8,8

    Water heating capacity

wood

kW

7,5

    Room heating capacity

wood

kW

1,3

Flue gas temperature 

wood / lignite

°C

182 / 160

Flue gas mass fl ow rate

wood / lignite

g/s

11,3 / 11,9

Required draught pressure

wood / lignite at rated heat output

mbar

0,20 / 0,21

Содержание VARIOLINE AC 105

Страница 1: ...Issued 06 2016 OPERATING MANUAL with INSTALLATION INSTRUCTIONS GB VARIO LINE AQUA THERM COMBI AC 105...

Страница 2: ...Outdoor air supply for combustion optional equipment 11 Examples of possible connections 11 9 Connection of the heating system 12 Heat output to water 12 Return flow temperature boost 12 Temperature...

Страница 3: ...preparation DIN 4751 Part 2 Safety devices for heating systems with flow temperatures of up to 110 C 120 C in preparation open and closed water heating systems up to 349 kW 300000 kcal h with thermost...

Страница 4: ...instructions regarding maintenance and cleaning in this operating manual Your chimney sweep will also be happy to clean the fireplace Only clean and properly adjusted appliances work efficiently 2 2...

Страница 5: ...trolley Transport by means of carrying straps included in the delivery Remove the fuel drawer hotplate and transport securing devices hook the four carrying straps into the stove base Figure 4 Insert...

Страница 6: ...12815 the Austrian standard NORM M 7550 the German industrial standards DIN 18882 DIN Plus BIMSCH as well as the special regulations concerning efficiency and pollutant emission applicable in Regensb...

Страница 7: ...n Remove cooking plate s and slacken stove frame mounting screws 12 pi eces Figure 6 Correctly position stove frame retighten stove frame mounting screws 12 pieces Replace cooking plate s Base recess...

Страница 8: ...nless steel 5 Sidewall 6 Control knob heating cooking operation 7 Thermometer 8 Fire door panel 9 Fire door handle stainless steel 10 Fire door viewing window extra charge 11 Control knob for primary...

Страница 9: ...ing minimum distances from combustible building materials clearance to wall 20 cm clearance to ceiling 40 cm Figure 10 Figure 11 Figure 12 With fire protection unit retrofitted Gap in kitchen plinth t...

Страница 10: ...pre fabricated components are preferable Assessment of the entire flue gas system according to DIN 4705 Parts 1 and 2 with shared flue systems according to Part 3 Connection stove chimney The flue pi...

Страница 11: ...requirements for the operation Even with an outdoor air supply for combustion the requirements for the operation of an appliance independent of indoor air room sealed appliance are not fulfilled of an...

Страница 12: ...ation and the calculation of the dimensions of the expansion tank must comply with DIN EN12828 and DIN EN13831 The expansion tank must be installed in rooms that are protected from frost For further d...

Страница 13: ...of symbols 1 Installation package 1 Installation package 1 Installation package Integrated return flow temperature boost Integrated return flow temperature boost Integrated return flow temperature bo...

Страница 14: ...his determines the rate of burning and therefore the heat output of the stove In position 0 the controller is closed no combustion air is supplied In posi tion 1 minimum air supply is provided select...

Страница 15: ...be heat exchanger and the radiated losses to the room where the stove is installed via the cooking surface or the oven and consequently the heat output to the room are reduced COOKING OPERATION Figure...

Страница 16: ...lames All three stages can occur at the same time from the inside to the outside of a piece of wood Clean combustion The first prerequisite for keeping pollutant emissions as low as possible is that o...

Страница 17: ...ir to position 6 and fully open the slider for the secondary air Open the firebox door Turn the operation mode control to Cooking operation Put 2 small pieces of firewood onto the grate Place a piece...

Страница 18: ...vered by warranty In any case this will lead to incomplete and inefficient combustion and subsequently to low efficiency with all appliances Cooking For cooking change the operating mode to cooking Co...

Страница 19: ...iance components flue gas pipe cooking plate grate cleaning cover ash pan ensure they are correctly positioned and function as required and or that there are no leaks When positioning the cooking plat...

Страница 20: ...ven If the appliance is overheated or if a gasket is damaged the inside of the glass viewing window of the oven may become fogged To clean it please proceed as follows Remove oven door as described an...

Страница 21: ...velopment of unsightly spots on the cooking plate and the stove will keep its good appearance Take care that the expansion gaps of the steel cooking plate are always kept free of deposit build ups so...

Страница 22: ...ave an abrasive effect on the shed around or have an abrasive effect on the shed around or have an abrasive effect on the glass ceramic surface This applies particularly to glass ceramic surface This...

Страница 23: ...draught Have the stove plate aligned or replaced Seek the advice of your chimney sweep if necessary install a dam per Stove frame or stainless steel components discoloured Clean surfaces seek the advi...

Страница 24: ...heat up Start up flap is open Close start up flap Incorrect chimney draught Contact your chimney sweep Output controller faulty Replace output controller Oven viewing glass becomes cloudy Stove overhe...

Страница 25: ...0 3 cm Example Stove frame overhang front 0 cm flue pipe connection at the side 18 cm clearance installation wall to rear wall stove 6 cm 105 60 18 15 3 0 6 3 68 14 5 6 5 85 13 5 18 19 5 14 5 1 25 64...

Страница 26: ...m position mm 100 250 Oven Width x height x depth mm 420 x 290 x 410 Cooking surface Width x depth mm 1008 x 507 Area m2 0 51 Ash drawer Stove litre 4 5 Fuel storage container Stove litre 34 5 Fuel co...

Страница 27: ...ns REPAIRS We will carefully check your appliance and establish whether the warranty claim is justified If yes we will decide in which way the defect should be corrected In the event of a repair we wi...

Страница 28: ...GMBH Landstra e 19 5231 Schalchen Austria Telephone 43 0 7742 5211 0 Telefax 43 0 7742 5211 109 of ce lohberger com www lohberger com Slight variations in colour due to printing process Subject to te...

Отзывы: