SECTION 2 — PREPARATION FOR USE

2-1 Initial Inspection

Check the shipping carton carefully for external

damage. If the carton shows evidence of abuse, ask
the carrier’s agent to be present when the unit is un-
packed. Carefully unpack the unit to avoid damaging
the equipment through the use of careless proce-
dures. Inspect all equipment for damages immediate-
ly after unpacking. Bent and broken parts, dents and
scratches should be noted. If damage is found, refer
to paragraph 2-2 for recommended claim proce-
dures. Keep all packing material for possible future
use.

2-2 Claims

If the unit has been damaged, notify the carrier im-

mediately. File a claim with the carrier and advise Lo-
gitek of such action to arrange for repair or
replacement without waiting for a claim to be settled
with the carrier.

2-3 Repacking for Shipment

If the unit must be returned to Logitek, attach a let-

ter to it showing the owner’s name and address. A de-
scription of necessary service should be included in
the letter. The original shipping carton and packaging
materials should be used for reshipment if possible.
Use FRAGILE labels on each surface. Return the unit
freight prepaid. Be sure to insure the unit for its full
value. The unit will be repaired promptly and returned
freight prepaid.

2-4 Installation

Rackmount Enclosure

The Ultra-VU rackmount models are designed to

be mounted in a standard 19" equipment rack by us-
ing the four mounting holes in the corners of the front
panel. Plastic washers should be used to keep the
mounting screw for marring the front panel finish.

Desktop Enclosure

The Ultra-VU desktop enclosure is designed to sit

on any flat surface. The front of the meter may be an-
gled up for easier viewing by raising the bale located
on the bottom of the box.

While flow through ventilation is not necessary,

the units should not be mounted directly above
equipment which produces significant heat, such as
equipment using vacuum tubes. The unit should
never be operated if the ambient temperature is
above 55 degrees C (131 degrees F).

2-5 Connecting Mains Power

Connect the meter to the power mains with the en-

closed power cord. The unit is factory set for 115VAC

operation unless specifically labeled otherwise, but
230VAC operation can be selected via a slide switch
located next to the power transformer inside the unit.
To gain access to the voltage select switch, remove
the enclosure top cover. The switch is located adja-
cent to the large power transformer.

2-6 Input Selection on Dual Input Models

If the digital receiver can lock onto an input signal

then the meter will display that signal whether it con-
tains errors or not. If no signal is connected to the
digital input or the data rate is out of the receiver’s
capture range, then the meter will display the analog
signal. This happens even if nothing is connected to
the analog inputs. The Ultra-VU can be forced to dis-
play only one input by connecting a remote switch to
the unit. Consult the factory for details.

2-7 Connecting Digital Input Models

The Ultra-VU accepts AES/EBU or S/PDIF serial

data at sample rates of 30,000 to 50,000 samples per
second via a female XLR connector on the rear panel.
The input is also wired directly to the male XLR con-
nector on the back panel for use in loop-through
mode. The loop-through connector provides a con-
venient way to daisy-chain several pieces of equip-
ment off of one digital output. Loop-through works
well with AES/EBU signals but should be limited to 10
feet with S/PDIF signals and cables.

S/PDIF signals using RCA type plugs may be con-

nected to the input using an RCA to XLR adapter.
Coax cables using BNC connectors can be con-
nected to the input using a BNC to XLR adapter. Both
adapters are available from Logitek.

AES/EBU Connection

Pin 1

Shield

Pin 2

Pin 3

Signal -

It is also important to set the two input load

switches located between the two XLR connectors.

Input Load Switch Settings

Sw1 Sw2 Ohms Use
Up

Up

2200

Loop-through mode

Up

Dn

110

balanced twisted pair (XLR)

Dn

Up

75

unbalanced coax (RCA & BNC)

Dn

Dn

44

do NOT use this combination

Page 5

** Ultra-VU Operation & Service Manual **

Содержание ULTRA-VU

Страница 1: ...ULTRA VU LED BARGRAPH AUDIO METER Operation Service Manual Logitek...

Страница 2: ...ngineer decompile disassemble or cre ate derivative works from the software You may not create copies of the software This statement will be governed by the laws of the State of Texas U S A Logitek re...

Страница 3: ...Resolution Mode 7 3 8 Auxiliary Data Display 7 3 9 Changing Display Brightness 7 3 10 CLIP indicator set point 7 3 11 Resetting the Program 7 SECTION 4 MAINTENANCE 4 1 General Information 8 4 2 Fuse 8...

Страница 4: ...o the ballistic standards described in IEEE document G 2 1 2 13 IEC document 268 and EBU document 3205 E This ensures that the bargraph motion will closely track other standard mechanical and elec tro...

Страница 5: ...er be operated if the ambient temperature is above 55 degrees C 131 degrees F 2 5 Connecting Mains Power Connect the meter to the power mains with the en closed power cord The unit is factory set for...

Страница 6: ...tches 6 7 and 8 as shown Zero Reference Setting Sw6 Sw7 Sw8 dBs below full scale Up Up Up 10 dB Up Up Dn 12 dB Up Dn Up 14 dB Up Dn Dn 16 dB Dn Up Up 18 dB Dn Up Dn 20 dB Dn Dn Up 20 dB Dn Dn Dn 20 dB...

Страница 7: ...single red segment that maintains the highest PPM reading for a user se lectable amount of time If the holding period expires before the PPM dot equals or exceeds the peak hold dot then the peak hold...

Страница 8: ...e meter in one second inter vals This function is active even when the received data is invalid Sample Rate Data Display Label Meaning 32 0 32 000 Hz 1 44 0 44 056 Hz 1 44 1 44 100 Hz 1 47 9 47 952 Hz...

Страница 9: ...may damage these devices 4 4 Access to Circuit Cards Access to the circuitry of the rackmount and half rack meters is accomplished by removing the six screws that attach the top cover The inside of t...

Страница 10: ...irst powered up it may generate noise up to 70 dBFS until it undergoes a calibration cycle 4 7 Digital Dual Input Control Card LG 265 Power from input connector P4 is connected to voltage regulators I...

Страница 11: ...ad pulse IC1 and IC2 drive the upper bargraph left chan nel IC3 and IC4 drive the lower bargraph right channel IC5 drives the scale indicator LEDs along the bottom edge of the display Avoid removing a...

Страница 12: ...500 Connectors P1 3 pin large header locking PN MLSS156 3A J1 3 pin large socket PN CE156F20 3A J2 Power entry module fuse holder SR 6200 4115 Switches S1 Slide DPDT CK L202 121MS02QE Transformers T1...

Страница 13: ...s J1 2 Female XLR NT NC3FK H J3 3 pin socket PN CE100F28 3A J4 3 pin large socket PN CE156F20 3A J6 7 10 pin dual row socket PN 050 010 455 P3 3 pin header PN MFSS100 3A P4 3 pin large header PN MFSS1...

Страница 14: ...crystal CT MP122 Resistors R1 2200 R2 110 R3 75 R4 1000 R5 6 100K R7 8 100K 2 5 position bussed CT 770 61 R104 R9 10 20K 8 position isolated SMD CT 767163203G R11 12 10K Switches S 1 8 Dip switch blo...

Страница 15: ...NMC1206Z5U104M50T C19 01uf AV 12065E103MATMA C20 21 1uf 35V tantalum AV TAP105K035HSB C22 01uf AV 12065E103MATMA C23 1 uf 50V ceramic SMD NC NMC1206Z5U104M50T C24 25 470pf 100V ceramic SMD AV 12061A47...

Страница 16: ...Microchip Technology Inc Chandler AZ MM Maxim Sunnyvale CA MO Motorola Semiconductor Products Phoenix AZ MP Mepcopal San Diego CA MU Murata Electronics Smyrna GA NC NIC Components Corp North Amityvil...

Страница 17: ...SECTION 7 Diagrams Page 17 Ultra VU Operation Service Manual...

Страница 18: ...Ultra VU Operation Service Manual Page 18...

Страница 19: ...Page 19 Ultra VU Operation Service Manual...

Страница 20: ...Pin5 5VDC The Mode button momentarily connects Pins 1 2 The Peak Hold button momentarily connects pins 3 2 Connect pins 4 5 to display the analog input when a valid digital input is present automatic...

Страница 21: ...Page 21 Ultra VU Operation Service Manual...

Страница 22: ...Ultra VU Operation Service Manual Page 22 1 2 3 4 5 6 Connector P3 Pin2 Pin5 5VDC The Mode button momentarily connects Pins 1 2 The Peak Hold button momentarily connects pins 3 2...

Страница 23: ...Page 23 Ultra VU Operation Service Manual...

Страница 24: ...Ultra VU Operation Service Manual Page 24...

Страница 25: ...Page 25 Ultra VU Operation Service Manual...

Страница 26: ...Ultra VU Operation Service Manual Page 26...

Страница 27: ...Page 27 Ultra VU Operation Service Manual...

Страница 28: ...Ultra VU Operation Service Manual Page 28...

Страница 29: ...Seller s obligation under this warranty shall be limited to such adjustment as Seller may ob tain from the original manufacturer This limited warranty is void if equipment is modi fied or repaired wit...

Отзывы: