Страница 2: ...ngineer decompile disassemble or cre ate derivative works from the software You may not create copies of the software This statement will be governed by the laws of the State of Texas U S A Logitek re...

Страница 3: ...Resolution Mode 7 3 8 Auxiliary Data Display 7 3 9 Changing Display Brightness 7 3 10 CLIP indicator set point 7 3 11 Resetting the Program 7 SECTION 4 MAINTENANCE 4 1 General Information 8 4 2 Fuse 8...

Страница 4: ...o the ballistic standards described in IEEE document G 2 1 2 13 IEC document 268 and EBU document 3205 E This ensures that the bargraph motion will closely track other standard mechanical and elec tro...

Страница 5: ...er be operated if the ambient temperature is above 55 degrees C 131 degrees F 2 5 Connecting Mains Power Connect the meter to the power mains with the en closed power cord The unit is factory set for...

Страница 6: ...tches 6 7 and 8 as shown Zero Reference Setting Sw6 Sw7 Sw8 dBs below full scale Up Up Up 10 dB Up Up Dn 12 dB Up Dn Up 14 dB Up Dn Dn 16 dB Dn Up Up 18 dB Dn Up Dn 20 dB Dn Dn Up 20 dB Dn Dn Dn 20 dB...

Страница 7: ...single red segment that maintains the highest PPM reading for a user se lectable amount of time If the holding period expires before the PPM dot equals or exceeds the peak hold dot then the peak hold...

Страница 8: ...e meter in one second inter vals This function is active even when the received data is invalid Sample Rate Data Display Label Meaning 32 0 32 000 Hz 1 44 0 44 056 Hz 1 44 1 44 100 Hz 1 47 9 47 952 Hz...

Страница 9: ...may damage these devices 4 4 Access to Circuit Cards Access to the circuitry of the rackmount and half rack meters is accomplished by removing the six screws that attach the top cover The inside of t...

Страница 10: ...irst powered up it may generate noise up to 70 dBFS until it undergoes a calibration cycle 4 7 Digital Dual Input Control Card LG 265 Power from input connector P4 is connected to voltage regulators I...

Страница 11: ...ad pulse IC1 and IC2 drive the upper bargraph left chan nel IC3 and IC4 drive the lower bargraph right channel IC5 drives the scale indicator LEDs along the bottom edge of the display Avoid removing a...

Страница 12: ...500 Connectors P1 3 pin large header locking PN MLSS156 3A J1 3 pin large socket PN CE156F20 3A J2 Power entry module fuse holder SR 6200 4115 Switches S1 Slide DPDT CK L202 121MS02QE Transformers T1...

Страница 13: ...s J1 2 Female XLR NT NC3FK H J3 3 pin socket PN CE100F28 3A J4 3 pin large socket PN CE156F20 3A J6 7 10 pin dual row socket PN 050 010 455 P3 3 pin header PN MFSS100 3A P4 3 pin large header PN MFSS1...

Страница 14: ...crystal CT MP122 Resistors R1 2200 R2 110 R3 75 R4 1000 R5 6 100K R7 8 100K 2 5 position bussed CT 770 61 R104 R9 10 20K 8 position isolated SMD CT 767163203G R11 12 10K Switches S 1 8 Dip switch blo...

Страница 15: ...NMC1206Z5U104M50T C19 01uf AV 12065E103MATMA C20 21 1uf 35V tantalum AV TAP105K035HSB C22 01uf AV 12065E103MATMA C23 1 uf 50V ceramic SMD NC NMC1206Z5U104M50T C24 25 470pf 100V ceramic SMD AV 12061A47...

Страница 16: ...Microchip Technology Inc Chandler AZ MM Maxim Sunnyvale CA MO Motorola Semiconductor Products Phoenix AZ MP Mepcopal San Diego CA MU Murata Electronics Smyrna GA NC NIC Components Corp North Amityvil...

Страница 17: ...SECTION 7 Diagrams Page 17 Ultra VU Operation Service Manual...

Страница 18: ...Ultra VU Operation Service Manual Page 18...

Страница 19: ...Page 19 Ultra VU Operation Service Manual...

Страница 20: ...Pin5 5VDC The Mode button momentarily connects Pins 1 2 The Peak Hold button momentarily connects pins 3 2 Connect pins 4 5 to display the analog input when a valid digital input is present automatic...

Страница 21: ...Page 21 Ultra VU Operation Service Manual...

Страница 22: ...Ultra VU Operation Service Manual Page 22 1 2 3 4 5 6 Connector P3 Pin2 Pin5 5VDC The Mode button momentarily connects Pins 1 2 The Peak Hold button momentarily connects pins 3 2...

Страница 23: ...Page 23 Ultra VU Operation Service Manual...

Страница 24: ...Ultra VU Operation Service Manual Page 24...

Страница 25: ...Page 25 Ultra VU Operation Service Manual...

Страница 26: ...Ultra VU Operation Service Manual Page 26...

Страница 27: ...Page 27 Ultra VU Operation Service Manual...

Страница 28: ...Ultra VU Operation Service Manual Page 28...

Страница 29: ...Seller s obligation under this warranty shall be limited to such adjustment as Seller may ob tain from the original manufacturer This limited warranty is void if equipment is modi fied or repaired wit...

Отзывы: