background image

Logika Technologies 

HMD-FOC Operation Manual            Rev 1.02   

  July 2016 

Web: www.logikatech.com    Phone: 905-597-7272    Fax: 905-597-7278    Email: [email protected] 

P a g e

 

9

 

 

NC (Normally Closed) pin (Pink) – Common (White) connected 

 

Connect Self test Pin (Purple) to 0VDC Pin (Yellow), Red LED will be ON.    Use multi-meter 

to measure the voltages on PNP output Pin (Blue) and NPN output pin (Black), referring to 

0VDC pin (Yellow):   
1.

 

For PNP output: 24VDC 

2.

 

For NPN output: 0VDC 

Measure the connection of Relay: 

NO (Normally Open) pin (Gray) – (White) connected 
NC (Normally Closed) pin (Pink) – Common (White) disconnected 

5.4  Troubleshooting 

 

Missed Target-

 If the LED does not turn red when hot metal is in its detection field: 

1.    The threshold potentiometer is set too low.    Go to Threshold Sensitivity Adjustment, 

Section 5.2, and recalibrate the sensitivity adjustment. 

2.    Check HMD’s location and make sure the detection field covers hot metal.   

 

Detector sends false target detect output   

1. The sensitivity is set too high.    Refer to Section 5.2, adjust sensitivity. 

2. If step 1 does not correct detector sending false output, check for background sources of 

radiation such as reflected sunlight or hot objects close to the detector.    Adjust the 

Lens direction to make sure the disturbance as little as possible, or blocking the 

interfering radiation source. 

 

 

Additional notes   

1.

 

No Power- Check that the wiring connections are correct, that the connections are 
secure and tight and that the power supply is proper and normal. 

6. Maintenance   

 

6.1  Regular Maintenance 

 

Diagnostics-

 the HMD-ST-FOC does not require maintenance at a fixed period other than 

periodic attention to the following to ensure consistent operation: 

 

Lens Cleaning-

 Routinely check the lens glass for dust or oil residue. Clean as required 

with soft lint free cloth and lens cleaner.   

 

Adjustments- 

The level of sensitivity (see Section 5.2) 

Содержание HMD-FOC

Страница 1: ...Logika Technologies Inc 1250B Reid Street Unit 12 Richmond Hill ON Canada L4B 1G3 HMD FOC Hot Metal Detector Static Mode Fiber Optical Cable Operator s Manual Revision 1 02...

Страница 2: ...ecifications 3 2 3 Operating Principle 3 2 4 Sensitivity Adjustment 3 3 OPTICAL LENS AND CABLE 4 3 1 A1 Lens 4 3 2 B1 Lens 5 3 3 Fiber Optical Cable 5 3 4 HMD Enclosure 6 4 WIRING CONNECTIONS 6 4 1 El...

Страница 3: ...includes a rugged IP66 enclosure protecting state of the art electronics and will withstand the harsh ambient conditions present in heavy industrial environments The HMD ST FOC is used primarily for...

Страница 4: ...teel braided Sensor detect Infrared range HT Model 500 C 1400 C 700nm 1200nm LT model 360 C 1400 C 900nm 1700nm Self testing TEST PIN Protection DC polarity output overload short circuit protection We...

Страница 5: ...com P a g e 4 3 Optical Lens and cable 3 1 A1 Lens Lens housing Cylindrical Stainless Steel with air purge Ambient Temperature 25 C 300 C 13 F 572 F Field of View Target temperature at 700 C No Ring...

Страница 6: ...ng Fiber Optical Cable Lens housing Cylindrical Stainless Steel with air purge Ambient temperature 25 C 300 C 13 F 572 F Field of View 4 5 other views can be special ordered Installation angle 45 Air...

Страница 7: ...ia a 12 pin connector with ground The HMD is supplied with a mating connector at the back of its enclosure and a standard 2 meter cable with a quick connect assembly This cable is also wired with ferr...

Страница 8: ...be used to protect the lens from dust and vapor Purge air cleans the lens reduces maintenance time and prolongs HMD ST FOC s life in dusty or corrosive environments Compressed Air Requirements Must b...

Страница 9: ...returns to its initial setting Sensitivity Adjust the Threshold Level Potentiometer upon installation to determine the base detector signal according to the application requirements As the potentiome...

Страница 10: ...Check HMD s location and make sure the detection field covers hot metal Detector sends false target detect output 1 The sensitivity is set too high Refer to Section 5 2 adjust sensitivity 2 If step 1...

Страница 11: ...echnologies at 1 888 856 4452 1 888 8LOGIKA with the Serial Number of your HMD before you return our product If we are unable to solve the problem by phone or email Logika will provide you with a retu...

Отзывы: