17
Natural Gas
•
In the United Kingdom flexible connections must not be used for built in product, rigid or semi-rigid pipework
must be used.
LP Gas
•
In the United Kingdom flexible type hoses must not be used for built in products, rigid or semi-rigid pipework
must be used. Ensure it is suitable for use on LP Gas up to 50mbar pressure rise.
•
In all other countries this appliance must be installed in accordance with local regulations and standards.
Method
1. Ensure that the gas taps are in the “
●
” position
2. Isolate the hob from the electrical supply
3. Remove all pan supports, burner caps, rings, crowns and
controls.
4. With the aid of a 7mm box spanner the burner injectors can
then be unscrewed and replaced by the appropriate injectors.
See the Burner configuration Table for details.
Note the size of the injector being removed to ensure the
corresponding size of the new injector is used, NG vs LPG.
To Adjust the Gas Rate
With the aid of a thin bladed screwdriver completely tighten down the bypass adjustment screw, which is located
down the centre of the gas tap control shaft or on the gas tap body. See further adjustments in the
next section.
Upon completion stick the replacement rating plate sticker on the under side of the hob.
Conversion from NG to LPG or from LPG to NG
The replacement / conversion of the gas hob should only be undertaken by Gas Safe Registered
Engineer. The hob is supplied for use with Natural Gas only and cannot be used on any other gas
without modification. It can be converted from NG to LPG or LPG to NG providing the correct
injectors are fitted and the gas rate is adjusted to suit.
LGHOBX10_Vestel_IB_110419_flo.indd 17