13
1. The wire which is coloured green and yellow must
be connected to the terminal marked E ( ) Earth.
2. The wire which is coloured blue must be connected
to the terminal marked N (Neutral).
3. The wire which is coloured brown must be
connected to the terminal marked L (Live).
4. Ensure all screws are adequately tightened. Do not
over tighten as you may risk damaging the screw
threads.
The plug and socket must be accessible after installation,
or an all-pole disconnection switch provided in the fixed
wiring in accordance with the local wiring regulations.
Installation
•
Prior to installation, ensure that the local distribution conditions (nature of gas and pressure) and the
adjustment of the product are compatible. The adjustment conditions for this product are stated on the data
plate.
•
Ensure that there is a mains socket within reach of the hob cable (1600 mm from the rear right of the product).
This must be accessible after installation or an all-pole disconnection switch must be provided in the fixed
wiring in accordance with the local wiring regulations. The mains cable must not touch any metal parts.
•
Ensure that your kitchen worktop is designed for use in a kitchen.
•
This appliance is not connected to a combustion products evacuation device. It shall be installed and
connected in accordance with current installation regulations. Particular attention shall be given to the
relevant requirements regarding ventilation.
Wiring
Should the mains lead of the appliance ever require replacing, we recommend that this be carried out by a
qualified electrician who will replace it with a lead of the same size and temperature rating.
The hob must be installed by a Gas Safe Registered engineer in accordance with the Gas Safety
(Installation and Use) Regulations and to the relevant standards. Please, ensure that, once the hob is
installed, it is easily accessible for the engineer in the event of a breakdown.
Green & Yellow = Earth
Blue = Neutral
Brown = Live
This appliance must be earthed.
L
L
N
N
L
N
The flexible mains lead is supplied connected to a BS1363 fused plug, having a fuse of 13Amp capacity. If this
plug does not fit the socket in your home, it should be replaced with a suitable plug as outlined below.
The wires in the mains lead are coloured in accordance
with the following code:
LGHOBX10_Vestel_IB_110419_flo.indd 13
20/04/2011 4:02 PM