Содержание SP-18L

Страница 1: ...MICROPROCESSOR TEMPERATURE CONTROLLER SERVICE MANUAL 1 8 l ...

Страница 2: ...on hold ENTER button for 2 sec 2 LCD display 3 Indicator lights 4 Device control buttons 5 Airflow start up indicator 6 Central heating pump start up indicator 7 Hot service water pump start up indicator 8 Loader start up indicator 9 7A fuse 2 SP 18L Manual 4 3 5 6 7 8 9 1 2 ...

Страница 3: ...s The device has four keys intended for its operation The key ENTER switching on the device entering the menu saving a parameter The key EXIT monitoring the boiler exit without saving changes The key scrolling through the menu changing parameters adjusting the temperature of the central heating switching on off the summer mode The key scrolling through the menu changing parameters adjusting the te...

Страница 4: ...ng and domestic hot water temperature is screened on the LCD display the device starts to operate CHANGE OF MONITORING THE BOILER Change of reading after pressing the key ENTER Monitoring the central heating and domestic hot water temperature Current power in the boiler monitoring the valve operation CHANGE OF THE CENTRAL HEATING TEMPERATURE Press the key the central heating temperature is flashin...

Страница 5: ...mperature is flashing on the display Select the appropriate temperature confirm by pressing the key ENTER SUMMER MODE Press the key the central heating temperature is flashing on the display Press and hold the key release it when two horizontal lines appear on the display instead of the temperature Confirm by pressing the key ENTER SWITCHING ON THE DOMESTIC HOT WATER PUMP Press the key the domesti...

Страница 6: ...g domestic hot water DOMESTIC HOT WATER HYSTERESIS enables to adjust a delay of starting up the domestic hot water pump by a set number of degrees e g while 2ºC hysteresis and 50ºC set temperature the pump starts up when the domestic water temperature drops to 48ºC CENTRAL HEATING DOMESTIC HOT WATER PRIORITY the device controls two pumps central heating domestic hot water The function lets determi...

Страница 7: ... heating priority there is no possibility to adjust a domestic hot water temperature higher than the central heating temperature The central heating priority function is equipped with the following safety function lack of starting up the domestic hot water pump when the temperature of hot water storage container is higher than the temperature of the water jacket in the boiler FUEL TYPE switching t...

Страница 8: ...etermined in minutes and the operation is determined as a time of ope ration of the feeder and fan It is determined in seconds These two para meters should be set so that the boiler does not go dead while on support FAN START UP the device automatically adjusts an adequate rotational speed of the fan the function of airflow start up is responsible for a start of the fan alone it is based on adjust...

Страница 9: ...s on or switches off the pump depending on the temperature When the thermostat is connected to the adjuster yes should be pressed in the function An arrow will appear in the upper right corner on the display CAUTION the function should not be enabled when no indoor thermo stat connected WORM TEMPERATURE the function together with the sensor placed on the pipe of the feeder allows to protect the bo...

Страница 10: ...timal way The fuel amount should be determined on the basis of an observation if the fuel runs through as not fully burnt its amount is decreased but when the fuel runs out and the flame moves back to the feeder s pipe the amount is increased Changes should be made every hour since the last modi fication Every time it is determined if the fuel amount is adequate After finding a correct setting the...

Страница 11: ...hamber If the result of this modi fication is satisfying the test is finished by confirming with the key ENTER Caution While modifying the amount of the fuel transported changes should not be confirmed with the key Enter The amount of the transport ed fuel is modified when the parameter is modified on the display While testing there is also the parameter of the boiler temperature on the display ex...

Страница 12: ...elative air humidity 95 7 I insulation class 8 7 A fuse 9 Controller has got function preventing from premature freezing of o installation in case oftemperature decrease below 6 C circulation pump starts up automatically 10 Controller is equipped with secondary protection emergenc MAX POWER TEST 0 40 C 35 85 Central heating temperature Break time s Feeding time s 8 Use 1 Connect feeder of CH and H...

Страница 13: ...40 C 3 Perform installation in accordance with par 5 Use 4 Device should be installed and operated in accordance with rules of operating electrical devices Controller must not be exposed to water or to conditions causing steam condensation i e rapid changes of ambient temperature 5 In cases of controller misoperation first check a the fuse b connections stability and technical condition of coopera...

Страница 14: ...14 12 Electric parameters 1 Supply voltage 230 V 50 Hz 2 Power consumption no ratings 2 W 3 Output ratings blower 100 W loader 100 W pumps CH 100 W HSW 100 W SP 18L Manual ...