25
GB
1
2
5
4
3
1
2
5
4
3
1
2
5
4
3
1
2
5
4
3
1
2
5
4
3
1
2
5
4
3
1
2
5
4
3
1
2
5
4
3
For the installation using 400V following operations:
1. Release both clips then open the terminal box lid. Remove the wire the cooker was supplied with.
2. Insert the links as shown,
400V 2N~50Hz
400V 2N~50Hz
400V 3N~50Hz
400V 3N~50Hz
Store the spare
link here
Store the spare
links here
3. Connect the wires as shown, ensure all screws are adequately tightened. Do not over tighten as you
may risk damaging the screw threads.
L3
L2
L1
N
4. Fix the supply cable in the cable clamp, tighten the cable clamp screw and close the cover.
• The power supply cable must have these minimum requirements:
– Type: H05VV-F (PVC insulated and sheathed flexible cable)
– 230V 1N~ 50Hz cores x 4 mm
2
minimum.
– 400V 2N~ 50Hz cores x 2.5 mm
2
minimum.
– 400V 3N~ 50Hz cores x 2.5 mm
2
minimum.
• This appliance must be earthed.
• The cooker must be connected to the mains supply with a switched (double pole) cooker outlet
providing full disconnection correctly fused with a capacity appropriate to that shown on the
cooker Rating Plate and incorporated in the fixed wiring in accordance with the latest wiring
regulations. All electrical wiring from the consumer unit to the cooker, via the switched double
pole cooker outlet, must be of the correct rating.
• The supply cable must be positioned away from any hot parts of the rear of the cooker.
If this cannot be done then another method of protecting the supply cable from the hot parts
must be used i.e. Heat resistant sleeving or high temperature cables.