Karbon 300 Rugged Computer
64
Field Name
Generic Device 2
Default Value
[Enabled]
Possible Value
Disabled / Enabled
Help
Enable/Disable Thermistor 2 device.
Field Name
Active Thermal Trip Point
Default Value
60
Possible Value
0~127
Help
This value controls the temperature of the ACPI Active Thermal Trip Point. NOTE: a value
of zero will cause the DPTF driver to disable the trip point.
Field Name
Passive Thermal Trip Point
Default Value
65
Possible Value
0~127
Help
This value controls the temperature of the ACPI Passive Thermal Trip Point. NOTE: a
value of zero will cause the DPTF driver to disable the trip point.
Field Name
S3/CS Thermal Trip Point
Default Value
70
Possible Value
0~127
Help
This value controls the temperature of the ACPI Critical Thermal Trip Point for entering
S3 or CS. NOTE: a value of zero will cause the DPTF driver to disable the trip point.
Field Name
Hot Thermal Trip Point
Default Value
75
Possible Value
0~127
Help
This value controls the temperature of the ACPI Hot Thermal Trip Point. NOTE: a value
of zero will cause the DPTF driver to disable the trip point.
Field Name
Critical Thermal Trip Point
Default Value
80
Possible Value
0~127
Help
This value controls the temperature of the ACPI Critical Thermal Trip Point. NOTE: a
value of zero will cause the DPTF driver to disable the trip point.
Field Name
Thermal Sampling Period
Default Value
50
Possible Value
0~100
Help
The polling interval in 10ths of seconds. A value of 0 tells the driver to use interrupts.
NOTE: The granularity of the sampling period is 0.1 seconds. For example, if the sam-
pling period is 30 seconds, then _TSP needs to report 300; if the sampling period is 0.5
seconds, then choose 5.