background image

Signal color change delay 

The signal color change delay be adjusted between approximately 1 and 127 seconds. 
This delay time affects the transition from yellow to green. If flashing yellow is enabled 
then the yellow to flashing yellow and flashing yellow to green transitions will have the 
same delay. The delay time is adjusted using a flat blade screwdriver inserted into the 
“pot” labeled “DELAY” on the circuit board. If you rotate it fully to the left you’ll get 
the minimum time delay. Rotating it fully to the right will give you the maximum time 
delay.  Set  the  delay  based  on  your  own  personal  preference.  On  smaller  layouts  you 
may  wish  to  have  a  shorter  delay  so  that  a  looping  train  does  not  run  into  a  red  or 
yellow  signal  it  just  caused  itself!  You  can  change  the  delay  time  as  you  wish  even 
when the power to the 

Block Animator

/2 is on. 

 

 

 

Figure 14 – time delay 

 
 
 

Visual Effects (True Lens2, Flashing Yellow, Signal Fade) 

The 

Block Animator

/2 not only retains the True Lens2 feature from the previous generation 

product but also introduces Flashing Yellow and Signal Fade effects.  

True Lens2

 reproduces the “bounce” of the prototype searchlight signal mechanism which 

briefly flashes red when transitioning from the aspect from yellow to green. True Lens2 is 
enabled by having switch #2 in the ON/CLOSED position as shown in Figure 8. NOTE: this 
feature is enabled independently of the SIG EB and SIG WB switches which simply indicate 
the physical wiring of the signal. It is up to you to determine if you want this visual enabled 
or disabled. 

 

 

 
 

Flashing  Yellow

  adds  another 

indication, Approach Medium, to the 
signal  sequencing.  When  enabled 
(switch  #9  in  the  ON/CLOSED 
position)  the  signals  will  sequence 
from red 

 yellow 

flashing yellow 

 green.  

 

 

 

Signal Fade 

reproduces the behavior 

of older prototype signals which used 
bulbs. As the indications change the 
aspects (colors) will fade off and on. 
To enable this feature switch #10 must 
be in the ON/CLOSED position. 

        

 

 
 

Power 

The 

Block Animator/2

 accepts AC or DC power (7 - 16V). Power consumption, including the signals, ranges from ~60 mA 

(photocell version) to ~225 mA (infrared version). If you are only using a single board then you can use the AC terminals to 
provide power as shown in Figure 15a. You can use the accessory terminals on your throttle/power pack. If you are using 
more than one 

Block Animator/2

 (for example, if you’re interlocking with turnout positions) then you should consider 

powering them all from a single 

DC

 source as shown in Figure 15b. Watch the polarity and make sure you know what is 

positive! Contact us if you are uncertain! 

When power is first applied the signal outputs will turn on briefly in sequence (Red 

 Yellow 

 Green). 

 

AC or DC

Power 

Source

7-16V

          

DC

Power 

Source

7-16V

-

+

 

 

           Figure 15a – AC power                                                                 Figure 15b – DC power 

 
 
 

Other Applications 

We have an instruction supplement and application notes on our website which cover topics such as interlocking a signal (i.e. 
force it to red) with the position of a turnout or controlling multi-headed signals. 

Содержание Block Animator/2

Страница 1: ...s on the circuit board These not only help you when first setting up the board but are also active when in operating mode The Flashing Yellow aspect has been added When enabled the signal will transit...

Страница 2: ...ows Signal EB will be illuminated whenever an eastbound train activates sensor W1 or sensor W2 Note that if the eastbound train activates and then clears sensor W1 but after 35 seconds hasn t activate...

Страница 3: ...ngement and the Atlas 3 light circular head not searchlight signals We offer the Block Animator 2 version BA2 CC or BA2 CC IR for that type of signal wiring You MUST use resistors with LED based signa...

Страница 4: ...ator 2 will think the train has actually backed up and exited the block W2 W1 E2 E1 Figure 7 Photocell wiring Photocells require a light source above them to function properly On most layouts the room...

Страница 5: ...detector in some plastic or metal tubing You can also recess the IR detector slightly below the ties and roadbed Figure 9a Figure 9b Using Across the rails Infrared With this sensor mode and physical...

Страница 6: ...ich means that when a train is detected the output is pulled to ground When no train is sensed the detector output is an open circuit or floating You will need 3 detection blocks or zones Figure 12 sh...

Страница 7: ...IG WB switches which simply indicate the physical wiring of the signal It is up to you to determine if you want this visual enabled or disabled Flashing Yellow adds another indication Approach Medium...

Страница 8: ...either of its detector input terminals and the GND terminal AND change the sensor mode to External Detector see Table 1 on page 3 The signal should immediately change to red If not then the Block Ani...

Отзывы: