background image

68 ohms

1/4 watt

Detector

Blue

wire

Black

wire

Emitter

Black

wire

White

wire

 

 

Figure 11 – IR component wiring  

(W1 input shown; replicate for E2, W2 and E1 inputs respectively) 

 

 

Using an external detector 

Use this sensor mode if you’d prefer to use a different type of detector such as an NCE BD20 current sensing detector. Any 
brand of detector should work provided that its output is an open collector, “active low” polarity, which means that when a 
train is detected the output is pulled to ground. When no train is sensed the detector output is an open circuit or “floating.”   
You will need 3 detection blocks or zones. Figure 12 shows how they would be partitioned. 

Signal

EB

Signal

WB

W          E

West approach block

East approach block

Center block

 

 

Figure 12 – External detector block/zone partitioning 

 

 

Figure 13 shows how simple it is to connect the BD20 block detectors to the 

Block Animator

/2.  

 

West 

approach

detector

GND

OUT

Center 

block

detector

GND

OUT

East 

approach

detector

GND

OUT

NCE BD20

GND

2
1

OUT

 

 

Figure 13 – External detector wiring (NCE BD20 shown) 

 

Содержание Block Animator/2

Страница 1: ...s on the circuit board These not only help you when first setting up the board but are also active when in operating mode The Flashing Yellow aspect has been added When enabled the signal will transit...

Страница 2: ...ows Signal EB will be illuminated whenever an eastbound train activates sensor W1 or sensor W2 Note that if the eastbound train activates and then clears sensor W1 but after 35 seconds hasn t activate...

Страница 3: ...ngement and the Atlas 3 light circular head not searchlight signals We offer the Block Animator 2 version BA2 CC or BA2 CC IR for that type of signal wiring You MUST use resistors with LED based signa...

Страница 4: ...ator 2 will think the train has actually backed up and exited the block W2 W1 E2 E1 Figure 7 Photocell wiring Photocells require a light source above them to function properly On most layouts the room...

Страница 5: ...detector in some plastic or metal tubing You can also recess the IR detector slightly below the ties and roadbed Figure 9a Figure 9b Using Across the rails Infrared With this sensor mode and physical...

Страница 6: ...ich means that when a train is detected the output is pulled to ground When no train is sensed the detector output is an open circuit or floating You will need 3 detection blocks or zones Figure 12 sh...

Страница 7: ...IG WB switches which simply indicate the physical wiring of the signal It is up to you to determine if you want this visual enabled or disabled Flashing Yellow adds another indication Approach Medium...

Страница 8: ...either of its detector input terminals and the GND terminal AND change the sensor mode to External Detector see Table 1 on page 3 The signal should immediately change to red If not then the Block Ani...

Отзывы: