background image

Logenex 

                                                                                                                                       

SCDM-SD Series Manual 1.0

 

 

8

 

 

1 Video Input 

– Use the Scroll Up/Down button to select 1 Video Input. 

Press  the  OK  button  to  enter  the  1  Video  Input  menu.  Use  the  Scroll 
Up/Down  button  to  select  the  Video  Input  option:  NTSC,  PAL,  ASI.  The 
factory default is NTSC. Press the OK button to set.   If the modulator has 
more  than  one  video  input  scroll  through  the  Advanced  Menu  for  the 
additional video input menus. 

 

1  Program  Num

 

–  Use  the  Scroll  Up/Down  button  to  select  1  Program 

Num.  Press  the  OK  button  to  enter  the  1  Program  Num  menu.  Use  the 
Scroll  Up/Down  button  to  select  the  desired  1  Program  Num  option 
ranging from 0 to 65535 then press the OK button to set. Factory default 
is 1001. If the modulator has more than one video input scroll through the 
Advanced Menu for the additional Program Num menus. 

 

1  Channel  Name

 

–  Use  the  Scroll  Up/Down button to select  1  Channel 

Name. Press the OK button to enter the 1 Channel Name menu. Use the 
Scroll Up/Down menu to select the first character of the desired Channel 
Name  then  press  the  OK  button  to  set.  Repeat  the  process  until  the 
Channel  Name  is  completed.  If  the  modulator  has  more  than  one  video 
input  scroll  through  the  Advanced  Menu  for  additional  channel  name 
menus. 

 

1  Aspect  Ratio

 

–  Use  the  Scroll  Up/Down  button  to  select  1  Aspect 

Ratio.  Press  the  OK  button  to  enter  the  1  Aspect  Ratio  menu.  Use  the 
Scroll Up/Down button to select the desired Aspect Ratio option of 4:3 or 
16:9  then  press  the  OK  button  to  set.  Factory  default  is  4:3.  If  the 
modulator  has  more  than  one  video  input  scroll  through  the  Advanced 
Menu for additional Aspect Ratio menus. 

  To 

exit the  Advanced  Menu

 use the Scroll Up/Down button to select  Exit then 

press  the  OK  button.  Exit  Exit  Menu  will  appear  on  the  LCD  screen.  Press  the 
OK button twice to exit. 

  Once the settings are made and the modulator is programmed (a) remove power 

from the unit by disconnecting the power supply cable from the DC 12V jack, (b) 
wait 5 seconds and (c) reconnect the power cable to the unit’s DC 12V jack. This 
will allow the modulator to capture the new settings.

 

 

 

 

 

 

 

 

 

Содержание SCDM-SD1

Страница 1: ...ON CONFIGURATION MANUAL SCDM SD1 SCDM SD2 SCDM SD4 Single Dual Quad Input QAM Modulators Logenex Innovations Inc 6A 7500 Martin Grove Rd Woodbridge Ontario L4L8S9 Tel 905 790 8823 Fax 289 371 3117 www logenex com ...

Страница 2: ...AFETY PRECAUTIONS 3 PACKAGE CONTENTS 3 SPECIFICATIONS 4 INSTALLATION 5 HARDWARE INSTALLANTION and CONNECTIONS 5 MODULATOR SETUP AND CONFIGURATION 5 INITIAL SETUP TO FACTORY DEFAULT 5 MODULATOR CONFIGURATION 6 CABLE PROVIDER SETUP 9 SCDM SD MODULATOR NOTES 9 ...

Страница 3: ...device if the power cord is damaged DO NOT cut the power cord DO NOT plug the power supply into an AC outlet until all cables and connections to the device have been properly connected The device should be installed in an environment consistent with its operating temperature specifications Placement next to heating devices and ducts is to be avoided as doing so may cause damage The device should n...

Страница 4: ...dB typical Connector Type F female F female F female MODULATION Video Resolution NTSC 720x480 30fps NTSC 720x480 30fps NTSC 720x480 30fps Video Compression MPEG2 MP ML MPEG2 MP ML MPEG2 MP ML Audio Compression MPEG1 Layer II MPEG1 Layer II MPEG1 Layer II Constellations 64 QAM 256 QAM 64 QAM 256 QAM 64 QAM 256 QAM Symbol Rate 5 056941 Msps 64QAM 5 360537 Msps 256QAM 5 056941 Msps 64QAM 5 360537 Msp...

Страница 5: ...h the unit s inputs IN1 IN4 depending on the SCDM SD model It is highly recommended that quality cables and connectors be used for all audio source connections 4 Use a quality 75Ω coaxial cable with F connectors from the unit s RF OUT jack to the distribution system combiner or reverse splitter or directly to a television 5 Connect the included 12VDC 3A power supply to the unit s DC 12V POWER jack...

Страница 6: ...set Constellation Use the Scroll Up Down button to select Constellation Press the OK button to enter the Constellation menu The modulator allows for either QAM256 or QAM64 Select the desired Constellation then press the OK button to set Interleaver Use the Scroll Up Down button to select Interleaver Press the OK button to enter the Interleaver menu Use the Scroll Up Down button to select the desir...

Страница 7: ...ream ID ranging from 0 to 65535 then press the OK button to set Factory default is 1000 Network ID Use the Scroll Up Down button to select Network ID Press the OK button to enter the Network ID menu Use the Scroll Up Down button to select the desired Network ID ranging from 0 to 65535 then press the OK button to set Factory default is 100 ORG Network ID Use the Scroll Up Down button to select ORG ...

Страница 8: ...e the Scroll Up Down menu to select the first character of the desired Channel Name then press the OK button to set Repeat the process until the Channel Name is completed If the modulator has more than one video input scroll through the Advanced Menu for additional channel name menus 1 Aspect Ratio Use the Scroll Up Down button to select 1 Aspect Ratio Press the OK button to enter the 1 Aspect Rat...

Страница 9: ...ut Channel 99 MHz Channel 96 Program Number 1 Program 1 988 Program 2 989 Program 3 990 Program 4 991 Cogeco 398 Output Channel 759 MHz Channel 118 Program Number 398 Shaw 716 Output Channel 855 MHz Channel 134 Constellation QAM64 Program Number 1 SCDM SD MODULATOR NOTES PRODUCT NOTES ITEM VALUE PASSWORD SERIAL NUMBER INSTALLATION DATE PURCHASE DATE VIDEO 1 INPUT VIDEO 2 INPUT VIDEO 3 INPUT VIDEO ...

Отзывы: