TROUBLE
PROBABLE CAUSE
CHECK AND REMEDY
1. Hook does not respond
to the control station
A.) No voltage at hoist-main line or
branch circuit switch open; branch
line fuse blown or circuit breaker
tripped.
A.) Close switch, replace fuse or reset
breaker.
B.) Phase failure (single phasing, three
phase unit only)-open circuit, grounded
or faulty connection in one line of supply
system, hoist wiring, reversing contactor,
motor leads or windings.
B.) Check for electical continuity and repair or
replace defective part.
C.) Upper or lower limit switch has opened
the motor circuit.
C.) Press the “other” control and the hook
should respond. Adjust limit switches as
described on pages 17-18.
D.) Open control circuit-open or shorted
winding in transformer, reversing contactor
coil or speed selecting relay coil; loose
connection or broken wire in circuit;
mechanical binding in contactor or relay;
control station contacts not closing or
opening.
D.) Check electrical continuity and repair or
replace defective part.
E.) Wrong voltage or frequency..
E.) Use the voltage and frequency indicated on
hoist identification plate.
For three phase dual voltage unit, make
sure the connections at the voltage conver-
sion board are the proper voltage as
described on page 8.
F.) Low Voltage.
F.) Correct low voltage condition as described
on page 9.
G.) Brake not releasing-open or shorted coil
winding; armature binding.
G.) Check electrical continutiy and connections.
Check that correct coil has been installed.
The coil for three phase dual voltage unit
operates at 230 volts when the hoist is
connected for either 230 volt or 460 volt
operation. Check brake adjustment as
described on page 16.
H.) Excessive load.
H.) Reduce loading to the capacity limit of hoist
as indicated on the identifcation plate.
2.) Hook moves in the wrong
direction.
A.) Wiring connections reversed at either the
control station or terminal board (single
phase unit only).
A.) Check connections with the wiring diagram.
B.) Failure of the motor reversing switch to
effect dynamic braking at time of reversal
(single phase unit only).
B.) Check connections to switch. Replace a
damaged switch or a faulty capacitor.
C.) Phase reversal (three phase unit only).
C.) Refer to installation instruction on page 8.
3.) Hook lowers but will not
raise.
A.) Excessive load.
A.) See item 1H.
B.) Open hoisting circuit-open or shorted
winding in reversing contactor coil or
speed selecting relay coil; loose connection
or broken wire in circuit; control station
contacts not making; upper limit switch
contacts open.
B.) Check electrical continuity and repair or
replace defective part. Check operation of
limit switch as described on page 10.
C.) Phase failure (three phase unit only).
C.) See item 1B.
Содержание CM Hoist
Страница 28: ...24 WIRING DIAGRAMS MODELS A AA B C E F H 110 115 1 50 60 VOLT...
Страница 29: ...25 WIRING DIAGRAMS MODELS A AA B C E F H 220 230 1 50 60 VOLT...
Страница 30: ...26 WIRING DIAGRAMS MODELS A AA B C E F H 220 230 3 50 60 OR 380 415 460 3 50 60 VOLT...
Страница 31: ...27 WIRING DIAGRAMS MODELS A AA B C E F H 220 230 3 50 60 OR 380 415 460 3 50 60 VOLT CSA UNITS...
Страница 32: ...28 WIRING DIAGRAMS MODELS A 2 AA 2 B 2 C 2 E 2 F 2 H 2 220 230 3 50 60 VOLT...
Страница 33: ...29 WIRING DIAGRAMS MODELS A 2 AA 2 B 2 C 2 E 2 F 2 H 2 220 230 3 50 60 VOLT CSA UNITS...
Страница 34: ...30 WIRING DIAGRAMS MODELS A 2 AA 2 B 2 C 2 E 2 F 2 H 2 380 415 460 3 50 60 VOLT...
Страница 35: ...31 WIRING DIAGRAMS MODELS A 2 AA 2 B 2 C 2 E 2 F 2 H 2 380 415 460 3 50 60 VOLT CSA UNITS...
Страница 36: ...32 WIRING DIAGRAMS MODELS A AA B C E F H 550 575 3 50 60 VOLT...
Страница 37: ...33 WIRING DIAGRAMS MODELS A AA B C E F H 550 575 3 50 60 VOLT CSA UNITS...
Страница 38: ...34 WIRING DIAGRAMS MODELS A 2 AA 2 B 2 C 2 E 2 F 2 H 2 550 575 3 50 60 VOLT...
Страница 39: ...35 WIRING DIAGRAMS MODELS A 2 AA 2 B 2 C 2 E 2 F 2 H 2 550 575 3 50 60 VOLT CSA UNITS...
Страница 40: ...36 WIRING DIAGRAMS MODELS J L R RT 110 115 1 50 60 VOLT...
Страница 41: ...37 WIRING DIAGRAMS MODELS J L R RT 220 230 1 50 60 VOLT...
Страница 42: ...38 WIRING DIAGRAMS MODELS J JJ L LL R RR RT RRT 220 230 3 50 OR 380 415 460 3 50 60 VOLT...
Страница 43: ...39 WIRING DIAGRAMS MODELS J JJ L LL R RR RT RRT 220 230 3 50 60 OR 380 415 460 3 50 60 VOLT CSA UNITS...
Страница 44: ...40 WIRING DIAGRAMS MODELS J 2 JJ 2 L 2 LL 2 R 2 RR 2 RT 2 RRT 2 220 230 3 50 60 VOLT...
Страница 45: ...41 WIRING DIAGRAMS MODELS J 2 JJ 2 L 2 LL 2 R 2 RR 2 RT 2 RRT 2 220 230 3 50 50 VOLT CSA UNITS...
Страница 46: ...42 WIRING DIAGRAMS MODELS J 2 JJ 2 L 2 LL 2 R 2 RR 2 RT 2 RRT 2 380 415 460 3 50 60 VOLT...
Страница 47: ...43 WIRING DIAGRAMS MODELS J 2 JJ 2 L 2 LL 2 R 2 RR 2 RT 2 RRT 2 380 415 460 3 50 60 VOLT CSA UNITS...
Страница 48: ...44 WIRING DIAGRAMS MODELS J JJ L LL R RR RT RRT 550 575 3 50 60 VOLT...
Страница 49: ...45 WIRING DIAGRAMS MODELS J JJ L LL R RR RT RRT 550 575 3 50 60 VOLT CSA UNITS...
Страница 50: ...46 WIRING DIAGRAMS MODELS J 2 JJ 2 L 2 LL 2 R 2 RR 2 RT 2 RRT 2 550 575 3 50 60 VOLT...
Страница 51: ...47 WIRING DIAGRAMS MODELS J 2 JJ 2 L 2 LL 2 R 2 RR 2 RT 2 RRT 2 550 575 3 50 60 VOLT CSA UNITS...
Страница 57: ...53 Notes...
Страница 62: ...58 LODESTAR LOWER HOOK BLOCK ASSEMBLY...
Страница 89: ...85 NOTES...
Страница 93: ...89 NOTES...