![Loctite CARTESIAN 200 series Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/loctite/cartesian-200-series/cartesian-200-series_operation-manual_1933806060.webp)
anb: Block series connection
waitCond
Waits in place until the following conditions are met.
ld count>=10
or flag
count is 10 or greater
or flag is ON
Condition 1
ldi #genIn1
ani #genIn2
#genIn1 is OFF
and #genIn2 is OFF
Condition 2
anb
Condition 1 is true and condition 2 is also true
endWait
End of condition line
orb: Block parallel connection
waitCond
Waits in place until the following conditions are met.
ld count>=10
or flag
Count is 10 or greater
or flag is ON
Condition 1
ldi #genIn1
ani #genIn2
#genIn2 is OFF
and #genIn2 is also OFF
Condition 2
orb
Condition 1 or condition 2 is true.
endWait
End of condition line
When there is “anb” and “orb” but no corresponding “Id” or “Idi”, “Error on point job” is displayed
and an error is recognized.
Features II CARTESIAN Benchtop Robot