![Loctite CARTESIAN 200 series Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/loctite/cartesian-200-series/cartesian-200-series_operation-manual_1933806025.webp)
Execute Condition
Categor
y
Command Parameters
Content
ld Boolean
Variable
or
Expression
ON input
ldi Boolean
Variable
or
Expression
OFF input
and Boolean
Variable
or
Expression
Serial ON input
ani Boolean
Variable
or
Expression
Serial OFF input
or Boolean
Variable
or
Expression
Parallel ON input
ori Boolean
Variable
or
Expression
Parallel OFF input
anb -
Blocks serial connection
Cond
itio
n
orb -
Blocks parallel connection
Sequencer
Categor
y
Command Parameters
Content
ld
Boolean Variable or
Expression
ON input
ldi
Boolean Variable or
Expression
OFF input
and
Boolean Variable or
Expression
Serial ON input
ani
Boolean Variable or
Expression
Serial OFF input
or
Boolean Variable or
Expression
Parallel ON input
Cond
itio
n
ori
Boolean Variable or
Expression
Parallel OFF input
out Output
Destination
Coil drive
set Output
Destination
Movement Holding Set
reset Output
Destination
Movement Holding Reset
pls Output
Destination
Output of the Leading Edge of Pulse
Coil
plf Output
Destination
Output of the Trailing Edge of Pulse
anb
Parallel Connection of Serial Circuit Blocks
orb
Serial Connection of Parallel Circuit Blocks
mps
Stores data in process of calculation
mrd
Reads out data in process of calculation
Cnne
ction
mpp
Reads out and resetting data in process of calculation
Oth
er
nop
No process
Features II CARTESIAN Benchtop Robot