background image

6

4. Installation (continued)

Note:

This installation uses luer lock adapters shipped with the valve. Any approved material line

with 1/8" N.P.T. connections will work.

Refer to Figure 4.
1. If desired, mount the valve to the bracket (1) option.

2.  Connect syringe to product inlet port (2) or connect material feedline to inlet port (2).

3. Connect valve actuating airline to air inlet port (3) and to an approved valve controller.

4.  Pressurize material reservoir (Material pressure not to exceed 100 psi).

5.  Activate the valve until all air has been purged from material line. It may be helpful to turn 

the valve upside down to purge air. Attach desired dispense tip (4) to the outlet 
luer lock adapter.

6. Secure the dispense tip with the valve needle retaining cap (5).

4.2 Adjusting Dispense Quantity

Shot size is dependent on the following factors:

1. Flow control adjustment - Turn end cap counterclockwise to increase material flow rate.

2. Length of actuation, set at controller (valve open time).

3.  Material supply pressure at reservoir.

4. Material viscosity.

5. Dispense tip size.

4.3 Shutdown

The valve does not need any special care for shut down periods of up to two weeks. If the valve is
not going to be used for more than two weeks, cleaning the system out with Loctite

®

Equipment

Flushing Solvent P/N 12121 is recommened.

5.  Maintenance and Cleaning 

The Micro Needle Valve is designed to dispense UV curing adhesives. Precautions have been
made to protect the adhesive within the valve from exposure to UV light. Over time, curing may
occur within the dispense tip and around the needle and luer assembly. Removing the luer
adapter will force most of the cured adhesive off the needle. 

5.1 Procedure for Replacing Luer Adapter

Warning! 
Disconnect all material and air pressure lines before performing any maintenance on 
this valve.

Disassembly

, Refer to Figure 5.

1. Relieve reservoir product pressure 
2. Remove needle retaining cap (2)
3. Remove dispense tip 
4. Use a 7/16" wrench to remove luer adapter (3) and o-ring (5). 
5. Examine valve needle rod (4) and clean off all cured material with Loctite

®

Equipment Flushing

Solvent P/N 12121. 

6.  Replace luer adapter (3) and o-ring (5) or clean luer adapter with Loctite

®

Equipment 

Flushing Solvent P/N 12121. 

7. Clean valve body (1) with Loctite

®

Equipment Flushing Solvent P/N 12121.

Содержание 98084

Страница 1: ...EQUIPMENT Operation Manual Loctite Micro Needle Valve Part Number 98084 ...

Страница 2: ...Sectional Views 4 3 Technical Data 4 4 Installation 5 6 4 1 Typical Pressure Time Set Up 5 4 1 1 Connecting the Airline and Product Feed Line 5 4 2 Adjusting Dispense Quantity 6 4 3 Shutdown 6 5 Maintenance and Cleaning 6 8 5 1 Procedure for Replacing Luer Adapter 6 5 2 Procedure for Replacing Needle Valve Assembly 7 5 2 1 Valve Components 8 6 Troubleshooting 8 7 Spare Parts Micro Dispense Valve 9...

Страница 3: ...under warranty the unit may be repaired only by an authorized Henkel Loctite service representative 1 3 Unpacking and Inspection Carefully unpack the valve and examine the items contained in the carton Inspect the valve for any damage that might have occurred in transit If such damage has occurred notify the carrier immediately Claims for damage must be made by the consignee to the carrier and sho...

Страница 4: ...ity and easy integration into automated applications The Micro Needle Valve is easily adapted to a variety of reservoirs It is capable of connecting to syringe barrels as small as 5ml to 30 ml Change the luer fitting to a tube fitting and any size pressure reservoir can be used The Micro Needle Valve provides productive solutions to many types of applications 2 Description 2 1 Operating Elements a...

Страница 5: ...spring 6 to return the needle rod back to its position to close the material path The Micro Needle Valve is capable of interfacing with pressure reservoirs or syringe barrels When using a pressure reservoir the adhesive is placed into a reservoir and a feed tube passes through the lid of the reservoir into the adhesive bottle The other end of the feed tube is connected to the material inlet port o...

Страница 6: ...nches 28 5 mm Weight 8 oz 227 g Port Size Fluid Inlet 1 8 N P T Air Inlets 10 32 UNF 2B Fluid Outlet Male Luer Lock Max Fluid Pressure 100 psi 7 bar Pneumatic Supply min 60 psi 4 8 Bar max 100 psi 7 Bar Air Quality Filtered 10 micron oil free non condensing Wetted Parts 303 Series Stainless Steel Teflon Figure 2 2 2 1 Valve Sectional Views ...

Страница 7: ...T x 1 4 Tube Included To Controller Single Function P N 98023 Shot Miser P N 98079 To Precision Regulator Gauge Valve P N 98099 Typical Set Up Integrated Semi Automatic Controller Reservoir P N 97007 97010 97017 97020 985281 Mounting Bracket Not Included 30 cc Syringe Airline Adapter Not Included PN 98084 SN XXXX Figure 3 Air Inlet Fluid Inlet 2 3 1 4 5 Figure 4 ...

Страница 8: ...nse tip size 4 3 Shutdown The valve does not need any special care for shut down periods of up to two weeks If the valve is not going to be used for more than two weeks cleaning the system out with Loctite Equipment Flushing Solvent P N 12121 is recommened 5 Maintenance and Cleaning The Micro Needle Valve is designed to dispense UV curing adhesives Precautions have been made to protect the adhesiv...

Страница 9: ...housing 1 7 Clean and inspect the needle rod 4 and luer adapter assembly 3 for wear and damage Replace parts as necessary 8 Replace O ring 8 if necessary Make sure to lubricate new O ring with silicone grease 997569 9 Remove the end cap 15 by turning counterclockwise 10 Carefully remove the spring 14 and the two nylon washers 16 11 Remove the retaining ring 13 12 Pull the needle rod and piston ass...

Страница 10: ...ully closed Turn end cap counterclockwise The valve needle retaining cap Tighten the retaining cap may not have been tightened enough to unseat the valve needle rod from the secondary Teflon seal Inconsistent material flow Inconsistent valve air pressure Insure that air supply is set at 60 psi Length of actuation too short Adjust time Check for curing in dispense needle Replace valve needle rod St...

Страница 11: ...dle Rod O ring Item 9 Flat Washer Nylon needle retain washer Item 8 Retaining Ring Item 6 Valve Body Assembly 98097 Body and Seal Sub assembly Item 1 Luer Assembly Item 3 O ring Item 5 Needle Retaining Cap Item 2 Socket Head Screws Item 16 Needle Retaining Cap 5 pack Item 2 98098 7 1 Accessories Bracket Flat Head Screw 985281 Precision Air Regulator Gauge Valve 0 30 psi with Syringe Airline Adapte...

Страница 12: ... BY ACCIDENT OR IF THE SYSTEM USED TO DISPENSE ANY LIQUID MATERIAL OTHER THAN LOCTITE PRODUCTS EXCEPT FOR THE EXPRESS WARRANTY CONTAINED IN THIS SECTION LOCTITE MAKES NO WARRANTY OF ANY KIND WHATSOEVER EXPRESS OR IMPLIED WITH RESPECT TO THE PRODUCTS ALL WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND OTHER WARRANTIES OF WHATEVER KIND INCLUDING AGAINST PATENT OR TRADEMARK INFRING...

Отзывы: