26
2.1
Displays, Operating Elements and Connections
☞
●
See the illustration on page 3.
1
Cover
2
Cover screw fasteners
3
Product connection 1/4“ (for 1/4“ product hose)
The 3/8“ product connection together with a 3/8“ product hose is included with the dispensing valve.
4
LED indicators, analog (automatic reservoir only)
2 green LED’s
= As long as one of these LED’s lights, adequate product is available in the bottle.
7 yellow LED’s = Refill.
If one of these LED’s lights, the next bottle of adhesive should be prepared for use.
The farther down the lit LED is, the less product is available.
1 red LED
= Empty.
The automatic reservoir is automatically depressurized by the controller 97102 or
97103 and can be automatically repressurized only after the replacement of the
empty product bottle with a full one (see Section 5.3).
5
Depressurizing valve
Valve position
– The reservoir is depressurized.
Valve position
– The reservoir can be pressurized.
6
Socket XS2/OUT (automatic reservoir only)
With the connection of two automatic reservoirs on a controller 97103, the automatic reservoir B is
connected here.
7
Equipment connector XS2/IN (automatic reservoir only)
The controller 97102 or 97103 is connected here.
8
Pneumatic connection P in
Connection for the external pneumatic supply.
Description
2
Содержание 97105
Страница 1: ...R R 97105 97106 97107 97108 ...
Страница 2: ......
Страница 5: ...5 Deutsch 6 22 English 23 39 ...