29
lococookers.com
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Burner will not light
using ignitor.
LP tank valve is closed.
Make sure the regulator is properly
attached to the LP tank. Turn LP tank
valve counterclockwise to open.
Bad connection between the
regulator and LP tank.
Make sure the regulator coupling nut is
fully tightened on the LP tank valve.
The LP tank is empty.
Re
fi
ll LP tank at an authorized dealer,
exchange or purchase new
fi
lled LP
tank.
Battery not installed correctly.
Make sure the
+
and
–
ends of the
battery are oriented properly. The
+
end
should be toward the ignitor button.
Weak or dead battery.
Replace with new alkaline AA battery.
Ignitor button not installed
correctly.
Unscrew ignitor button and reinstall.
Make sure threads are aligned and
engaged fully.
Wires or electrode covered in
cooking residue.
Clean wire and/or electrode with rubbing
alcohol.
Electrode and burners are wet.
Wipe dry with clean cloth.
Electrode cracked or broken -
sparks at crack.
Contact customer service for
replacement parts.
Ignitor malfunctioning.
Contact customer service for
replacement parts.
Burner will not light with
a match.
LP tank valve is closed.
Make sure the regulator is properly
attached to the LP tank. Turn LP tank
valve counterclockwise to open.
Bad connection between the
regulator and LP tank.
Make sure the regulator coupling nut is
fully tightened on the LP tank valve.
The LP tank is empty.
Re
fi
ll LP tank at an authorized dealer,
exchange or purchase new
fi
lled LP
tank.
Obstruction of gas
fl
ow.
Clean burner tubes and check for bent
or kinked gas hose.
Disengagement of burner to
valve.
Re-engage burner and valve.
Burner ports clogged or
blocked.
Clean burner ports.
Irregular
fl
ame pattern.
Flame does not run the
full length of the burner.
Burner ports are clogged or
blocked.
Clean burner ports.