BATTERY POWERED LOCK WITH ACCESS CONTROL
INSTALLATION AND WIRING INSTRUCTIONS
Battery Operating Information
Low Battery Indication:
When a valid code or is entered the green LED will flash during the unlock
time. If the batteries are weak, the red LED will flash for several seconds before the
green LED flashes. This is the indication to change the batteries.
Checking the Batteries:
Set the voltmeter for DC voltage at a scale above 6 volts. Place the meter probes
onto the two outer connectors of the four pin battery harness.
V
OLTMETER
R
EADING
6.2 V
OLTS
4.5 V
OLTS OR
L
ESS
B
ATTERY
C
ONDITION
F
RESH
B
ATTERIES
-F
ULL
S
TRENGTH
R
EPLACE
B
ATTERIES
Replacing the Batteries:
1. Remove the four dead batteries and replace with four new batteries.
NOTES:
• Always replace batteries as a set.
• Use only quality alkaline batteries.
ERROR CODE CHART
An error has occurred when the red LED
stays on solid and the green led flashes
N times. Count the green flashes and
refer to the chart below.
N
ERROR DESCRIPTION
2
CODE TOO LONG
3
MEMORY FULL
4
CAN’T DELETE MASTER CODE
5
2nd MASTER ENTRY NOT
SAME AS 1st
6
INVALID COMMAND
7
NOT USED
8
CODE TOO SHORT
9
DUPLICATE CODE
12
LOCKOUT
RELOCK DELAY
1. Enter master code.
2. Enter 9 9 *.
3. Press * key for the desired relock time. The red LED will blink once for each second
.