background image

 

3

Important Safety Instructions 

 

WARNING – To reduce the risk of injury or death: 

1) READ AND FOLLOW ALL INSTRUCTIONS. 
2) Never let children operate or play with gate controls. Keep the remote control away from children. 
3) Always keep people and objects away from the gate. NO PERSON SHOULD CROSS THE PATH OF 
THE MOVING GATE. 
4) Test the gate opener monthly. The gate MUST reverse on contact with a rigid object or stop when an 
object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate opener. 
Failure to adjust and retest the gate opener properly can increase the risk of injury or death. 
5) Use the emergency release only when the gate is not moving. 
6) KEEP GATES PROPERLY MAINTAINED. Read the owner’s manual. Have a qualified service person 
make repairs to gate hardware. 
7) The entrance is for vehicles only. Pedestrians must use separate entrance. 
8) SAVE THESE INSTRUCTIONS. 

Safety Instructions for Installation 

A. Install the gate opener only when: 
1) The opener is appropriate for the construction of the gate and the usage Class of the gate, 
2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum 
of 4 feet (1.22 m) above the ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through 
the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open 
position, 
3) All exposed pinch points are eliminated or guarded. 
4) Guarding is supplied for exposed rollers. 
B. The opener is intended for installation only on gates used for vehicles. Pedestrians must be supplied with 
a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. 
Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of 
travel of the vehicular gate. 
C. The gate must be installed in a location so that enough clearance is supplied between the gate and 
adjacent structures when opening and closing to reduce the risk of entrapment.   
D. The gate must be properly installed and work freely in both directions prior to the installation of the gate 
opener. Do not over-tighten the opener clutch or pressure relief valve to compensate for a damaged gate. 
E. For gate openers utilizing Type D protection: 
1) The gate opener controls must be placed so that the user has full view of the gate area when the gate is 
moving. 
2) The placard provided marked in letters at least 1/4-in (6.4-mm) high with the word 

WARNING

 and the 

following statement or the equivalent: “ Moving Gate Has the Potential of Inflicting Injury or Death – Do Not 
Start Gate Unless Path is Clear” shall be placed adjacent to the controls, 
3) An automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed. 
4) No other activation device shall be connected. 
F. Controls intended for user activation must be located at least ten feet (10’) away from any moving part of 
the gate and where the user is prevented from reaching over, under, around or through the gate to operate 
the controls. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. 

Содержание SFG 18H

Страница 1: ...www WholesaleGateOpener com Rev 11a...

Страница 2: ...7 Installation Overview 8 Installation of the Opener 8 Manual Operation 9 Fit The Rack 9 Installation of the Limit Switch 11 Connecting of the Control Board 11 Setting of the Control Board 13 Test the...

Страница 3: ...rrying out any work on the installation Also disconnect any buffer batteries if fitted Fit an omnipolar or magnetothermal switch on the mains power supply having a contact opening distance equal to or...

Страница 4: ...lied for exposed rollers B The opener is intended for installation only on gates used for vehicles Pedestrians must be supplied with a separate access opening The pedestrian access opening shall be de...

Страница 5: ...nside and outside of a vehicular horizontal slide gate 2 One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate 3 One or more contact sensors shall be locate...

Страница 6: ...othly along its entire run and there is no excessive side slipping The opening and closing gate stops are positioned WARNING Remember that control devices are intended to facilitate gate operation but...

Страница 7: ...6 It is suggestion that there is a 4 10cm distance at least between the gate edge and the gate wall when the gate is fully open Parts List...

Страница 8: ...4 Dimensions 38 28 36 CM Class of gate opener I II Features Easy to install and low maintain Midway mode Quick selection for gate open close direction Reliable rolling code technology Emergency releas...

Страница 9: ...pener You will need screwdrivers an electric drill wire cutters and a wire stripper a socket set and possibly access to a welder When install the opener you should build a concrete pad to support the...

Страница 10: ...he lock cover Now the key slot appears 2 Insert the T handle Key provided to the key slot and turn it in counter clockwise 135 to disengage the clutch between the gear shaft and power output Now the o...

Страница 11: ...from dealer if necessary 2 Put one end of rack section on the gear of opener as a temporary support Make rack level and mark the rack s mounting holes three holes on the gate 3 Weld the rack nut on t...

Страница 12: ...nstall the magnet bracket so that the opener will stop at the desired open position when the open limit switch approaches it The higher magnet bracket must be installed at left side and lower magnet b...

Страница 13: ...12 4 Alarm Lamp Optional One wire of the alarm lamp should be connected into the 4 terminal another should be connected into the 5 terminal...

Страница 14: ...should be connected into the 12 terminal 9 Wired Keypad 12VDC Optional The RED wire of the wired keypad should be connected into the 12 terminal The BLACK wire of the wired keypad should be connected...

Страница 15: ...to adjust the CLOSE stall force of the gate operator Turn the potentiometer clockwise to increase the stall force Turn the potentiometer counter clockwise to decrease the stall force Test the reversi...

Страница 16: ...en erased How to use the remote to control the operator Key A is used to operate the operator to work alternately open stop close stop open When the Midway Mode function is enabled Key B is used to ac...

Страница 17: ...ckets position b Please try to exchange the limit switch wires CL close and OP open There are two reed switches inside the magnetic limit switch one is upper and another is lower Maybe the magnet posi...

Страница 18: ...www WholesaleGateOpener com 7106 S 220th St Kent WA 98032 USA sales WholesaleGateOpener com 2010 2012 LockMaster All Rights Reserved...