background image

Page  1

27

90

3.5

39

32

160

 Use for 90 ~180  open hollow metal or solid wooden doors.
 Built-in microcontroller. Automatic current output control

      according to the door leaf position. The current is being
      lowered to 210mA after 6 seconds of door leaf positioning
      in order to cut down power consumption and lower the
      temperature of the lock body.

 Special wearable design. Mechanic life of more than

      200,000 times. 

 Adjustable wiring methods according to the environment.
 Adjustable lock time( 0 sec. & 3 sec. ).
 1 set of push button control contact is available.

 Lock indicator is available for lock status.

 

Features

SL-166A(B) Dead Bolt Lock Installation Manual

Unit: mm

 Accessories

Lock body X 1  

5-PIN Connector

M5X25mm X 

2

Screws 

M4X15mm X 

4

Screws 

M5X8mm X 

4

Screws 

M4X8mm X 

8

Screws 

X2 Shims(small)
  For strike plate

X2 Shims(large)
  For lock body

Bolt

14mm (Throw) X 12.7mm (Diameter)

Safety Measures

(1)Fail-safe electric lock
(2)Built-in photo couplers door open

push button input contact.

Door will lock again automatically when

door is not open within 6 seconds.

 

Specifications

Door position reed contact (0.25A@30VDC)

Lock status sensor

Maximum 41

 (

)

Room temperature 30

Operation temperature

DC 12V 

10%  

Power supply

 Temperature 0-70

,Humidity85%Rh max 

Operation environment

0,3 sec.

( Adjustable)

 Delay Time

Mechanic life

More than 200,000 times

Operation current

Standby:210mA

10%;  

Operation:570mA

10%

 

Current and Temperature Chart

Current
  (MA)

Time (sec.)

Time (sec.)

Temperature

Start

Stand-by

Door Close
Door Lock 
Delay Timer

 If delay time of 3 seconds.

Door closed when power is on.

5

60

50

40

30

20

 Adjusting before installation

Unscrew the top cover, adjust delay time.

  Adjusting automatic lock time: 
 (Reset after adjusting)

0

SEC.

3

SEC.

1

(Default)

Wiring direction according to the
environment.

3

OR

2

The wires through the 
rubber hole

 

Connections

 

Attention: There are only 2 screws on the back of the panel.

Push button contact as dry contact. NO voltage input to prevent 
damage to the unit.

Current input

Screws 

Strike plate X1  

Push button input contact

COM.

N.O.

N.C.

Red:
Brown:
Green:
Blue:
Purple:
Yellow: 

Door position detection reed is only able to sustain load of  

     0.25A@30VDC. An external relay is suggested if higher current
     to control. 

SL-166A has NC and COM contacts

( Environment: Room  temperature 30

,

 Humidity 60% Rh, DC12V )

Lock Control - 

Kouterbaan 63

 - 1840 Malderen - Belgium - Tel.  +32 52 57 43 02 - [email protected] - www.lockcontrol.be