background image

13

4  

Hydronic piping 

(continued)

Anti-scald mixing valves

Anti-scald valves used with water heaters are also called 
tempering valves or mixing valves. An anti-scald valve mixes 
cold water with the outgoing hot water to assure that hot 
water reaching a building fixture is at the correct temperature. 
A mixing valve is required when the Thermal-Stor is used to 
generate domestic hot water.

The temperature of water going to the fixtures may be more 
carefully controlled through the use of a thermostatic mixing 
valve.  This device blends a controlled amount of cold water 
with the hot water leaving the tank so that water at a more 
constant temperature exits the mixing valve. Always consult 
the mixing valve manufacturer’s instructions and guidelines for 
correct piping and usage. 

 WARNING

An anti-scald mixing valve does not 
eliminate the risk of scalding.

• 

Feel water before bathing or showering.

• 

If anti-scald or anti-chill protection is 

  required, use devices specifically 
 

designed for such service. Install 

 

these devices in accordance with their 

 manufacturer’s 

instructions.

ASSE1017 and ASSE1070 certified mixing 
valves are required.

 NOTICE

 WARNING

Hot water can scald! To avoid scalding 
potential, mixing valves must be selected and 
installed according to valve manufacturer’s 
instructions and recommendations. Mixing 
valves should be installed by a licensed 
contractor.

       

Installation & Operation Manual

Содержание TSU150

Страница 1: ...ller service technician Read all instructions before installing Perform steps in the order given Failure to comply could result in severe personal injury death or substantial property damage WARNING S...

Страница 2: ...ty damage NOTICE indicates special instructions on installation operation or maintenance that are important but not related to personal injury or property damage HAZARD DEFINITIONS 2 PLEASE READ BEFOR...

Страница 3: ...plate Consider piping and installation when determining appliance location Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee...

Страница 4: ...nger equipment life for the solar thermal system and heat source If piped correctly the buffer tank can also function as a hydraulic separator effectively separating the flow in the boiler loop from t...

Страница 5: ...TSU257 30 34 2 2 240 2875 TSU350 36 40 2 2 340 3775 TSU423 36 40 2 2 420 4650 TSU504 42 46 2 2 495 5475 TSU650 48 52 2 2 645 7050 TSU752 48 52 2 2 745 8100 TSU940 48 52 2 2 920 10000 AUXILIARY HEAT OU...

Страница 6: ...g Measurements From Floor Model A in B in C in D in E in F in G in H in I in O in P in TSU150 2 1 4 10 3 4 21 1 4 28 3 4 33 50 1 4 55 1 4 71 75 3 4 3 1 2 3 1 2 TSU200 2 1 4 11 1 4 22 3 4 33 38 1 2 55...

Страница 7: ...exchanger w tank Table 1E Tank with Spherical Measurements Model Spherical Model A in B in TSU150 SHX40000 44 1 2 28 TSU200 SHX40000 48 1 4 32 TSU257 SHX40001 50 1 4 34 TSU350 SHX40001 56 1 4 40 TSU4...

Страница 8: ...sen for the tank is capable of supporting the weight This tank must be placed where leakage from the relief valve leakage from the related piping or leakage from the tank or connections will not resul...

Страница 9: ...tor Take appropriate safety measures when carrying out any installation work on the roof and observe all relevant accident prevention regulations It is the installer s responsibility to comply with th...

Страница 10: ...AR PUMP STATION CONTROLLER TEMPERATURE GAUGE TYPICAL SPHERICAL HEAT EXCHANGER SOLAR SENSOR FILL AND FLUSH VALVE PRESSURE RELIEF VALVE IMG00095 TEMPERATURE GAUGE EXPANSION TANK Figure 3 2 Solar System...

Страница 11: ...the Thermal Stor buffer tank can be used to heat domestic water The hottest water is taken from the auxiliary heat supply and piped to the indirect heater where it is used to heat domestic potable wat...

Страница 12: ...in Section VIII Division 1 paragraph UG 125 a All pressure vessels within the scope of this division irrespective of size or pressure shall be provided with pressure relief devices in accordance with...

Страница 13: ...e tank so that water at a more constant temperature exits the mixing valve Always consult the mixing valve manufacturer s instructions and guidelines for correct piping and usage WARNING An anti scald...

Страница 14: ...y local codes NOTICE BACKFLOW PREVENTER PRESSURE REDUCING VALVE PRESSURE GAUGE AIR SEPARATOR LOW TEMP ZONE ZONE 1 ZONE 2 HIGH LOW RETURN TEMPERATURE GAUGE EXPANSION TANK PRESSURE RELIEF VALVE IMG00123...

Страница 15: ...RE GAUGE EXPANSION TANK MIXING VALVE PRESSURE RELIEF VALVE IMG00125 ZONE CIRCULATORS TYPICAL UNION Y STRAINER TYPICAL BOILER CIRCULATOR T P GAUGE DRAIN PRESSURE RELIEF VALVE CHECK VALVE SHOCK ARRESTOR...

Страница 16: ...IN PRESSURE RELIEF VALVE SHOCK ARRESTOR CHECK VALVE DOMESTIC HOT WATER DOMESTIC COLD WATER MAKE UP WATER SPACE HEAT SUPPLY AUXILIARY HEAT SUPPLY Y STRAINER TYPICAL BRAISED PLATE HEAT EXCHANGER Please...

Страница 17: ...meant to show system piping concept only the installer is responsible for all equipment and detailing required by local codes NOTICE Figure 4 5 DHW Priority Piping Multiple Temperature Space Heating...

Страница 18: ...ion make sure that this system is properly maintained Annual service by a qualified service technician should include the following Any procedure required by local codes Verify system pressure Air ven...

Страница 19: ...section If antifreeze is used in the heat source water check the concentration Heat source water including additives must be non toxic having a toxicity rating or class of 1 as listed in the Clinical...

Страница 20: ...Revision Notes Revision A ECO C08886 initial release TSU I O Rev A 11 11 Printed in U S A...

Отзывы: