Hazard definitions

The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels 
or to important information concerning the life of the product.

 

CAUTION

 CAUTION

 NOTICE

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious 
injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious 
injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate 
injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not 
avoided, may result in property damage.

NOTICE indicates special instructions on installation, operation, or maintenance that are important but not 
related to personal injury or property damage.

Contents

CONTENTS .......................................................................  2

HAZARD DEFINITIONS ...................................................  2
1.  GENERAL INFORMATION ........................................  3
     Tank construction ...................................................... 3-4 
2.  INSTALLATION ...........................................................  5
     Transporting and unpacking the unit ............................  5
     Examining the unit .......................................................  5
     Anchoring the unit .........................................................  5
     Recommended service clearances  .............................  5
     Connecting the hot water source ............................... 5-6
     Cold water supply .......................................................... 6
     Hot water outlet ............................................................  6
     Mixing valve ..................................................................  6
     Aquastat / bulbwell ........................................................ 7
     Piping the relief valve ...................................................  7 

     Drain .............................................................................  7
     Completing the installation ...........................................  7 
3.  OPERATION ................................................................  8
     Startup procedure .......................................................... 8 
     Shutdown procedure ...................................................... 8 
4.  INSPECTION ...............................................................  9
5.  MAINTENANCE .........................................................  10
     Flushing the tank ........................................................  10
     Cleaning the tank ................................................... 10-11
     Magnesium anode rod inspection ...............................  12
     Water piping and valve replacement ..................... 12-13
     Notes.......................................................................13-15
Revision Notes ..................................................  Back Cover

Hot Water Can Scald!

• 

Water heated to temperatures for clothes washing, dish washing, and other sanitizing needs can 

 

scald and cause permanent injury.

•  Children, elderly, and infirm or physically handicapped persons are more likely to be 
 

permanently injured by hot water.  Never leave them unattended in a bathtub or shower.  

 

Never allow small children to use a hot water tap or draw their own bath.

•  If anyone using hot water in the building fits the above description, or if state laws or 
 

local codes require certain water temperatures at hot water taps, you must take special 

 precautions:
 

 

• 

Use lowest possible temperature setting.

 

 

•  Install some type of tempering device, such as an automatic mixing 

 

 

 

valve, at hot water tap or water heater.  Automatic mixing valve must be selected and 

 

 

 

installed according to valve manufacturer’s recommendations and instructions.

• 

Water passing out of drain valves may be extremely hot.  To avoid injury:

 

• 

Make sure all connections are tight.

 

• 

Direct water flow away from any person.

Protection Must Be Taken Against Excessive Temperature and Pressure!
--Installation of a Temperature & Pressure (T&P) relief valve is required.

 

WARNING

 DANGER

Содержание Thermal-Stor 100 Series

Страница 1: ...he information contained in this manual is intended for use by qualified professional installers or service technicians Consult your local expert for proper installation or service procedures Save thi...

Страница 2: ...ain 7 Completing the installation 7 3 OPERATION 8 Startup procedure 8 Shutdown procedure 8 4 INSPECTION 9 5 MAINTENANCE 10 Flushing the tank 10 Cleaning the tank 10 11 Magnesium anode rod inspection 1...

Страница 3: ...HP750G and HP1000G Tank Orientation Lochinvar Heat Pump Storage Tanks are constructed in a vertical orientation Tank Lining Lochinvar Heat Pump Storage Tanks are constructed with glass lining ASME Al...

Страница 4: ...ttempting any procedures 5 Assure that all incoming and outgoing water lines have been shut off at the manual shutoff valves WARNING Heated water presents situations that can be very dangerous due to...

Страница 5: ...r heater Tapping locations on the water heater may vary by product or manufacturer Figure 2 1_Single Pass Piping Diagram One Heater One Tank MIXING VALVE CHECK VALVE EXPANSION TANK ISOLATION VALVE CIR...

Страница 6: ...cold water supply to the recirculation piping between the heater s and the tank s NOTICE If the cold water supply to the system is equipped with an in line check valve or backflow preventer a suitable...

Страница 7: ...y handle the capacity of the relief valve and discharge line Check local codes to assure compliance If a check valve has been installed on the inlet water line thermal expansion may take place causing...

Страница 8: ...nstallation operation and maintenance procedures to avoid possible injury or death Shutdown procedure 1 Turn off all power to the circulating pump and the hot water source controls 2 Close all valves...

Страница 9: ...nections RECOMMENDED INSPECTIONS To Be Inspected Time Interval Per Manufacturer Specs Weekly Monthly Quarterly Annually Circulating Pump Gauges Pressure Temperature Lines Inlet Outlet Return Pressure...

Страница 10: ...es supplied in glass lined storage tanks Hot water will be released under pressure Avoid contact with the hot discharge water to prevent the risk of severe scald injury Flushing the storage tank Since...

Страница 11: ...in the tank 7 Use hand tools to remove all sediment from the interior of the tank Use care not to damage the interior lining of the storage tank 8 Use a water hose to flush the remaining sediment from...

Страница 12: ...t seem feasible to replace inlet and outlet water lines and shutoff valves without shutting down the entire unit it is not advised Unless the unit is completely shut down and the water and the energy...

Страница 13: ...13 Storage Tank Installation and Operation Manual Notes...

Страница 14: ...Notes 14 Storage Tank Installation and Operation Manual...

Страница 15: ...15 Notes Storage Tank Installation and Operation Manual...

Страница 16: ...vision Notes Revision A PCP 3000042118 CN 500030128 initial release Revision B PCP 3000045095 CN 500032686 reflects the addition of Series 100 to the manual cover MM 100339374_DIR 2000596325_Rev B 04...