background image

Thermal-Stor™ HEAT PUMP 

STORAGE TANK

INSTALLATION and OPERATION 

MANUAL

Series:  100

The information contained in 
this manual is intended for use by 
qualified professional installers, or 
service technicians.  Consult your 
local expert for proper installation 
or service procedures.

Save this manual for future reference.

100339374_2000596325_Rev B

LOW LEAD CONTENT

WARNING

Содержание Thermal-Stor 100 Series

Страница 1: ...he information contained in this manual is intended for use by qualified professional installers or service technicians Consult your local expert for proper installation or service procedures Save thi...

Страница 2: ...ain 7 Completing the installation 7 3 OPERATION 8 Startup procedure 8 Shutdown procedure 8 4 INSPECTION 9 5 MAINTENANCE 10 Flushing the tank 10 Cleaning the tank 10 11 Magnesium anode rod inspection 1...

Страница 3: ...HP750G and HP1000G Tank Orientation Lochinvar Heat Pump Storage Tanks are constructed in a vertical orientation Tank Lining Lochinvar Heat Pump Storage Tanks are constructed with glass lining ASME Al...

Страница 4: ...ttempting any procedures 5 Assure that all incoming and outgoing water lines have been shut off at the manual shutoff valves WARNING Heated water presents situations that can be very dangerous due to...

Страница 5: ...r heater Tapping locations on the water heater may vary by product or manufacturer Figure 2 1_Single Pass Piping Diagram One Heater One Tank MIXING VALVE CHECK VALVE EXPANSION TANK ISOLATION VALVE CIR...

Страница 6: ...cold water supply to the recirculation piping between the heater s and the tank s NOTICE If the cold water supply to the system is equipped with an in line check valve or backflow preventer a suitable...

Страница 7: ...y handle the capacity of the relief valve and discharge line Check local codes to assure compliance If a check valve has been installed on the inlet water line thermal expansion may take place causing...

Страница 8: ...nstallation operation and maintenance procedures to avoid possible injury or death Shutdown procedure 1 Turn off all power to the circulating pump and the hot water source controls 2 Close all valves...

Страница 9: ...nections RECOMMENDED INSPECTIONS To Be Inspected Time Interval Per Manufacturer Specs Weekly Monthly Quarterly Annually Circulating Pump Gauges Pressure Temperature Lines Inlet Outlet Return Pressure...

Страница 10: ...es supplied in glass lined storage tanks Hot water will be released under pressure Avoid contact with the hot discharge water to prevent the risk of severe scald injury Flushing the storage tank Since...

Страница 11: ...in the tank 7 Use hand tools to remove all sediment from the interior of the tank Use care not to damage the interior lining of the storage tank 8 Use a water hose to flush the remaining sediment from...

Страница 12: ...t seem feasible to replace inlet and outlet water lines and shutoff valves without shutting down the entire unit it is not advised Unless the unit is completely shut down and the water and the energy...

Страница 13: ...13 Storage Tank Installation and Operation Manual Notes...

Страница 14: ...Notes 14 Storage Tank Installation and Operation Manual...

Страница 15: ...15 Notes Storage Tank Installation and Operation Manual...

Страница 16: ...vision Notes Revision A PCP 3000042118 CN 500030128 initial release Revision B PCP 3000045095 CN 500032686 reflects the addition of Series 100 to the manual cover MM 100339374_DIR 2000596325_Rev B 04...