FOR YOUR INFORMATION

START UP CONDITIONS

CONDENSATE

Whenever the water heater is fi lled with cold water, some condensate 
will form while the burner is on. A water heater may appear to be leaking 
when in fact the water is condensate. This usually happens when:

a.  A new water heater is fi lled with cold water for the fi rst time.
b.  Burning gas produces water vapor in water heaters, particularly 

high effi ciency models where fl ue temperatures are lower.

c.  Large amounts of hot water are used in a short time and the refi ll 

water in the tank is very cold.

Moisture from the products of combustion condense on the cooler 
tank surfaces and form drops of water which may fall onto the burner 
or other hot surfaces to produce a “sizzling” or “frying” noise.

Because of the suddenness and amount of water, condensate water 
may be diagnosed as a “tank leak”. After the water in the tank warms 
up (about 1-2 hours), the condition should disappear.

Do not assume the water heater is leaking until there has been enough 
time for the water in the tank to warm up.

An undersized water heater will cause more condensation. The water 
heater must be sized properly to meet the family’s demands for hot 
water including dishwashers, washing machines and shower heads.

Excessive condensate may be noticed during the winter and early 
spring months when incoming water temperatures are at their 
lowest.

Good venting is essential for a gas fi red water heater to operate 
properly as well as to carry away products of combustion and water 
vapor.

SMOKE/ODOR

It is not uncommon to experience a small amount of smoke and odor 
during the initial start-up. This is due to burning off of oil from metal 
parts, and will disappear in a short while.

THERMAL EXPANSION

CLOSED WATER SYSTEMS

Water supply systems may, because of code requirements or such 
conditions as high line pressure, among others, have installed devices 
such as pressure reducing valves, check valves, and back fl ow preventers. 
Devices such as these cause the water system to be a closed system.

THERMAL EXPANSION

As water is heated, it expands (thermal expansion). In a closed system 
the volume of water will grow. As the volume of water grows there will be 
a corresponding increase in water pressure due to thermal expansion. 
Thermal expansion can cause premature tank failure (leakage). This type 
of failure is not covered under the limited warranty. Thermal expansion 
can also cause intermittent temperature-pressure relief valve operation: 
water discharged from the valve due to excessive pressure build up. The 
temperature-pressure relief valve is not intended for the constant relief 
of thermal expansion. This condition is not covered under the limited 
warranty.

A properly sized thermal expansion tank should be installed on all 
closed systems to control the harmful effects of thermal expansion. 
Contact a local plumbing service agency to have a thermal expansion 
tank installed.

STRANGE SOUNDS

Possible noises due to expansion and contraction of some metal parts 
during periods of heat-up and cool-down do not necessarily represent 
harmful or dangerous conditions.

Condensation causes sizzling and popping within the burner area 
during heating and cooling periods and should be considered normal. 
See “Condensate” in this section.

OPERATIONAL CONDITIONS

SMELLY WATER

In each water heater there is installed at least one anode rod (see parts 
section) for corrosion protection of the tank. Certain water conditions 
will cause a reaction between this rod and the water. The most common 
complaint associated with the anode rod is one of a “rotten egg smell” 
in the hot water. The smell is a result of four factors which must all be 
present for the odor to develop:

a.  A concentration of sulfate in the supply water.
b.  Little or no dissolved oxygen in the water.
c.  A sulfate reducing bacteria which has accumulated within the water 

heater (this harmless bacteria is nontoxic to humans).

d.  An excess of active hydrogen in the tank. This is caused by the 

corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater 
models by replacing the anode(s) with one of less active material, 
and then chlorinating the water heater tank and all water lines. 
Contact the local water heater supplier or service agency for further 
information concerning an Anode Replacement Kit and this chlorination 
treatment.

If the smelly water persists after the anode replacement and chlorination 
treatment, we can only suggest that chlorination or aeration of the 
water supply be considered to eliminate the water problem.

Do not remove the anode leaving the tank unprotected. By doing 
so, all warranty on the water heater tank is voided.

“AIR” IN HOT WATER FAUCETS

HYDROGEN GAS: Hydrogen gas can be produced in a hot water 
system that has not been used for a long period of time (generally 
two weeks or more). Hydrogen gas is extremely fl ammable  and 
explosive. To prevent the possibility of injury under these conditions, we 
recommend the hot water faucet, located farthest away, be opened for 
several minutes before any electrical appliances which are connected 
to the hot water system are used (such as a dishwasher or washing 
machine). If hydrogen gas is present, there will probably be an unusual 
sound similar to air escaping through the pipe as the hot water faucet 
is opened. There must be no smoking or open fl ame near the faucet 
at the time it is open.

HIGH WATER TEMPERATURE SHUT OFF SYSTEM

This water heater is equipped with an automatic gas shut-off system. 
This system works when high water temperatures are present. Turn 
“OFF” the entire gas supply to the water heater. The high temperature 
shut-off is built into the gas control valve. It is non-resettable. If the 
high temperature shut-off activates, the gas control valve must be 
replaced. Contact your gas supplier or service agency.

Содержание RESIDENTIAL GAS WATER HEATERS

Страница 1: ...HEATER WAS PURCHASED IF YOU ARE UNSUCCESSFUL CONTACT RESIDENTIAL TECHNICAL ASSISTANCE AT 1 615 889 8900 OR VIA E MAIL AT 2TECH LOCHINVAR COM RESIDENTIAL GAS WATER HEATERS For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER GAMA certification applies to all residential gas water heaters with capacities of 20 to 100 gallons with input rating of 75 000 BTU Hr or less 300 Maddox S...

Страница 2: ...defects or other reproductive harm and requires businesses to warn of potential exposure to such substances WARNING This product contains a chemical known to the State of California to cause cancer birth defects or other reproductive harm This appliance can cause low level exposure to some of the substances included in the Act IMPORTANT DEFINITIONS Qualified Installer A qualified installer must ha...

Страница 3: ...3 GENERAL SAFETY ...

Страница 4: ...les the water heater will not operate properly It could cause DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE This manual contains instructions for the installation operation and maintenance of the gas fired water heater It also contains warnings throughout the manual that you must read and be aware of All warnings and all instructions are essential to the proper operation of the water heater a...

Страница 5: ...ntally vented gas fueled heating appli ance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors and si...

Страница 6: ... X Gas Control Valve Thermostat Y Metal Drain Pan Z Air Intake Screen Base Pan AA Inner Door B B Outer Door CC HSI Burner Assembly D D Air Intake Screen Blower Assembly E E FV Sensor Bracket Assembly 40K 50K Models Only F F FV Sensor Bracket Assembly 55K 62 5K Models Only NATURAL HOT SURFACE IGNITER MAIN BURNER HOT SURFACE IGNITOR SENSOR PROPANE HOT SURFACE IGNITER MAIN BURNER HOT SURFACE IGNITOR ...

Страница 7: ...njured by hot water than others These include the elderly children the infirm or physically mentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies you...

Страница 8: ... drain pan that trigger an alarm or turn off the incoming water to the water heater when leakage is detected Sensors mounted in the metal drain pan that turn off the water supply to the entire home when water is detected in the metal drain pan Water supply shut off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heate...

Страница 9: ...exceeds the National Appliance Energy Conversation Act standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary Should you choose to apply an insulation blanket to this heater you should follow these instructions For identification of components mentioned below see Figure 1 Failure to follow these instructions can restrict the air flow required fo...

Страница 10: ...oors through vertical ducts each opening shall have a minimum free area of 1 square inch per 4 000 Btu per hour 5 5 cm2 kW of total input rating of all equipment in the enclosure see Figure 8 3 When communicating with the outdoors through horizontal ducts each opening shall have a minimum free area of 1 square inch per 2 000 Btu per hour 11 cm2 kW of total input rating of all equipment in the encl...

Страница 11: ...igher than required for domestic water purposes a mixing valve must be installed Please refer to Figure 2 for suggested piping arrangement CLOSED WATER SYSTEMS Water supply systems may because of code requirements or such conditions as high line pressure among others have installed devices such as pressure reducing valves check valves and back flow preventers Devices such as these cause the water ...

Страница 12: ... Relief Valves for Hot Water Supply Systems ANSI Z21 22 CSA 4 4 and the code requirements of ASME If replaced the valve must meet the requirements of local codes but not less than a combination temperature and pressure relief valve certified as indicated in the above paragraph The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water he...

Страница 13: ...pply line serving the water heater and A drip leg sediment trap ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas control valve A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit Be sure to check all the gas piping for leaks before lighting the water heater Use a soapy water sol...

Страница 14: ...ust flow from the hot water faucet before turning ON gas to the water heater To fill the water heater with water 1 Close the water heater drain valve by turning the handle to the right clockwise The drain valve is on the lower front of the water heater 2 Open the cold water supply valve to the water heater NOTE The cold water supply valve must be left open when the water heater is in use 3 To insu...

Страница 15: ... This powered vent heater operates on 110 120 Vac therefore a grounded outlet must be within reach of the six 6 foot 1 8 m flexible power cord supplied with the unit see Figure 1 The power cord supplied may be used only where local codes permit If local codes do not permit the use of a flexible power supply cord a Make sure the unit is unplugged from wall outlet Remove screws and open panel on fro...

Страница 16: ...ions in this manual before completing the installation and putting the water heater into service Except where instructed in this manual the mixing of 2 3 and 4 vent pipe is NOT ALLOWED If 2 pipe is to be used then a 2 to 3 bell reducer is recommended Figure 15 shows the recommended location for the bell reducer If the bell reducer is located at the rubber boot on the blower assembly then a short s...

Страница 17: ... used in between all 45 elbows and all 90 elbows 55 000 and 62 500 BTU Units NOTE The 55 000 and 62 500 BTU Units are not approved for 2 venting For 3 Venting the maximum equivalent feet of pipe allowed is 80 feet 24 4 m This does not include the supplied Vent Termination for the water heater For the 3 venting one 90 elbow is approximately equal to 5 feet 1 5 m One 45 elbow is approximately equal ...

Страница 18: ...plied for decorative purposes only and is not a requirement for the vent termination if not needed by the installer VERTICAL VENT THROUGH ROOF This unit is approved for venting through the roof with the type vent terminal that is included with the unit A proper flashing or BOOT should be used to seal the pipe where it exits the roof The total vent system should not exceed that which is specified s...

Страница 19: ...s 15 2 cm and above PRIMER It is recommended that Tetrahydrofuran THF be used to prepare the surfaces of pipe and fittings for solvent welding Do not use water rags gasoline or any other substitutes for cleaning PVC or CPVC surfaces A chemical cleaner such as MEK may be used CEMENT The cement should be a bodied cement of approximately 500 to 1600 centipoise viscosity containing 10 20 by weight vir...

Страница 20: ... to the distance and make a second mark as the primer and cement will most likely destroy your first one Apply primer to the surface of the pipe and fitting socket with a natural bristle brush This process softens and prepares the PVC or CPVC for the solvent cementing step Move quickly and without hesitation to the cementing procedure while the surfaces are still wet with primer E Application of s...

Страница 21: ...21 ...

Страница 22: ...s If a suitable area is not available a cover should be installed over the thermostat to prevent tampering The water temperature setting was factory set at the lowest temperature Pressing the COOLER button decreases temperature and pressing the HOTTER button increases the temperature Setting the water heater temperature at 120 F 49 C Approx mark on temperature setting of the gas control valve will...

Страница 23: ... expansion Contact a local plumbing service agency to have a thermal expansion tank installed STRANGE SOUNDS Possible noises due to expansion and contraction of some metal parts during periods of heat up and cool down do not necessarily represent harmful or dangerous conditions Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be consider...

Страница 24: ... Viewport on the Inner Door see Figure 1 The main burner should provide complete combustion of gas ignite rapidly give reasonably quiet operation and cause no excessive flame lifting from the burner ports If the proper flame characteristics are not evident see Figure 20 make sure that the flow of combustion and ventilation air is not blocked on the Air Intake Screen at the base of the water heater...

Страница 25: ...ing instructions and replace the temperature pressure relief valve with a new one If the temperature pressure relief valve on the appliance weeps or discharges periodically this may be due to thermal expansion You may have a check valve installed in the water line or a water meter with a check valve Consult your local water supplier or service agency for further information Do not plug the tempera...

Страница 26: ...the tank Droplets form and drip onto the burner or run on the floor This is common at the time of start up after installation and when incoming water is cold I Water in the water heater bottom or on the floor may be from condensation loose connections or the relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps tak...

Страница 27: ...acket 40K 50K models only 26B FV Sensor Bracket 55K 62 5K models only 27 Nipple with Heat Trap 28 Secondary Anode with Heat Trap Not Shown Optional Now that you have purchased this water heater should a need ever exist for repair parts or service simply contact the company it was purchased from or direct from the manufacturer listed on the rating plate on the water heater Be sure to provide all pe...

Страница 28: ...nd intake air pipe direct vent products was used per the installation instructions that came with the water heater 3 Ensure the maximum number of elbows or maximum equivalent feet of vent or intake air pipe have not been exceeded per the installation instructions that came with the water heater 4 Ensure there are no obstructions in the vent or intake air pipe 5 Open igniter circuit 1 Check wiring ...

Страница 29: ...in to clear these error codes 2 Replace the gas control valve thermostat if the error code persists 14 either open or shorted 1 Turn off power to the water heater Ensure all FV sensor wiring the ignitor assembly plug and the ignitor assembly socket on the bottom of the Intelli Vent control are making good contact Repair or replace any worn damaged components that are not making good connection 2 R...

Страница 30: ...d be utilized by a qualified service agent When calling for service notify the service agent that this is a Flammable Vapor Ignition Resistant Product TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES Figure 1 and 15 Page 9 ...

Страница 31: ...31 NOTES ...

Страница 32: ...32 300 Maddox Simpson Parkway Lebanon TN 37090 Phone 615 889 8900 Fax 615 547 1000 Technical Services email 2tech lochinvar com www lochinvar com Copyright 2011 Lochinvar LLC All rights reserved ...

Отзывы: